• Title/Summary/Keyword: Horizontal fin

Search Result 85, Processing Time 0.029 seconds

The effect on fatigue life for dynamic behavior of external fuel tank horizontal fin (외부 연료탱크 수평 핀 동적거동이 피로수명에 미치는 영향)

  • Kim, Geun-Won;Shin, Ki-Su
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.3
    • /
    • pp.209-214
    • /
    • 2012
  • Recently, there were significantly increased cracks failure for external fuel tank horizontal fin of F-5 aircraft. In this paper, the dynamic behavior of horizontal fin was to quantitate by using Finite Element Method. To achieve this goal, the fatigue analysis for time and frequeucy domain has been performed by using the dynamic load spectrum of speed brake. In conclusion, it was proved that fatigue life of the horizontal fin was reduced by the influence of dynamic behavior.

Study on the pressure drop of ternary refrigerant R-407c during condensation inside horizontal micro-fin tubes (3성분 혼합냉매 R-407c의 수평 마이크로핀관내 응축압력강하에 관한 연구)

  • 정재천
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.210-218
    • /
    • 1998
  • Experimental results for forced convection condensationof Refrigerant-22 and ternary Refrigerant-407c(HFC-32/125/134a 23/25/52 wt%) considered as a substitute R-22 inside horizontal micor-fin tubes are presented. The test section was horizontal double-tubed counterflow condenser with a length 4000 mm micro-fin tube having 9.53 mm OD., 0.2 mm fin height and 60 fins. The refrigerants R-22 and R-407c were cooled by a coolant circulated in a surrounding annulus. The range of parameters of mass velocity was varied from 102.1 to 301.0kg/($\textrm{m}^{2}.s$) with inlet quality 1.0. Both refrigerant R-22 and its alternative refrigerant R-407c were tested within the same range of parameters. At the given experimental conditions for R-22 and R-407c the pressure drops for R-407c were considerably higher than those for R-22 at micro-fin tubes. Over the mass velocity range tested the PF(penalty factor)was lower than the increasing ratio of heat transfer area by fins. Based on the data correlation was proposed for predicting the frictional pressure drops for R-22 and R-407c for a duration of condensation inside a horizontal micro-fin tube.

  • PDF

A Study on the condensate Retention at Horizontal Integral-Fin tubes (낮은 핀을 가진 수평관의 응축액 억류에 관한 연구)

  • 한규일;조동현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.151-165
    • /
    • 1996
  • Relation between condensate retention and heat transfer performance is studied for condensation of CFC-11 on horizontal integral-fin tubes. Eight tubes with trapezoidally shaped integral fin density from 738fpm to 1654fpm and 10, 30 grooves are tested. The liquid retention angles are measured by the height gauge, and each tube is tested under static(non-condensing) condition (CFC-11, water) and under dynamic(condensing) condition (CFC-11). The analytical model predicts the amount of liquid retention on a horizontal integral-fin tubes within+10 percent over most of the data. Average retention angle increases as both surface tension-to-density ratio($\sigma/\rho$) and fin density(fpm) increase, The tube having a fin density of 1299~1654fpm has the best heat transfer performance. The amount of surface flooding must keep below of 40 percent for best heat transfer performance at condensation. The tube having low number of fin density must be used for fluids having high values of $\sigma/\rho$(water, (TEX)$NH_3$, ect.) and the tube having high number of fin density must be used for the fluid having low values of $\sigma/\rho$(R-11, R-22, etc.)

  • PDF

An experimental investigation of natural convection heat transfer from fin arrays on a horizontal flat plate (水平平板에 附着된 핀配列에서의 自然對流 熱傳達에 관한 實驗的 硏究)

  • 오원균;조진호;권순석
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.1
    • /
    • pp.26-32
    • /
    • 1988
  • A study has been conducted experimentally on the natural convection heat transfer characteristics of fin arrays on a horizontal flat plate in air. The effects of fin heights and Rayleigh numbers are mainly investigated. The experimental results are as follows; 1. The mean fin and mean total Nusselt numbers increase as dimensionless fin heights increase at 0.67.leg.H/s.leg.1.67. The mean plate Nusselt numbers increase in case of upward facing fins, but they decrease in case of downward facing fins. 2. The mean Nusselt numbers increase as Rayleigh numbers increase. 3. The mean fin surface Nusselt numbers has its maximum outside surface (Y$_{1}$) where there is no interference from each other fin. 4. The mean total Nusselt numbers in case of upward facing fins increase by 47% and 26%, respectively at H/S=0.67 and 1.67 than those in case of downward facing fins for Ra$_{s}$=6.50*10$^{3}$.>.

  • PDF

Natural Convection from a Vertical Flat Plate with Horizontal Rectangular Fins (수직평판(垂直平板)에 부착(附着)된 수평(水平)핀에서의 자연대류(自然對流))

  • Kim, S.J.;Lee, J.C.;Seo, L.S.;Kwon, S.S.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.448-455
    • /
    • 1988
  • A study has been conducted experimentally on natural convection heat transfer characteristics of a vertical flat plate with horizontal rectangular fins in air. The effects of fin heights and Rayleigh numbers are mainly investigated. The experimental results are as follows; 1. The mean fin, plate and total Nusselt numbers decrease as dimensionless fin heights H/S increase at $0.50{\leq}H/S{\leq}2.00$. 2. The mean fin surface Nusselt number in case of H/S = 0.50 and $Ra_c=4.33{\times}10^3$ shows its maximum at $X_1$, surface where there is no interference with other fins. 3. Owing to the interference of fins the mean plate Nusselt numbers at H/S=0.50 and 2.00 for $Ra_S=6.57{\times}10^3$ are 35% and 80% respectively less than the mean fin Nusselt numbers. 4. The mean fin, plate and total Nusselt numbers of horizontal rectangular fins show higher values at short fins, but lower values at long fins than those of upward vertical fins.

  • PDF

A Study of Flare Operation Method for The Fighter with An External Center Fuel Tank (동체 중앙에 연료탱크를 장착한 전투기의 섬광탄 운용 방안 연구)

  • Kang, Chi-Hang;Jang, Young-Il;Kwon, Ky-Beom;Yoon, Young-In
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.7
    • /
    • pp.616-622
    • /
    • 2012
  • In this paper, we examined the problems of the flare operation of tactic maneuvering flight of fighter aircraft with 150GL center external fuel tank and proposed the possible solution of it's operation. The damage scope of horizontal fin of fuel tank and flare trajectory when the flare ejected from the maneuvering aircraft were analyzed by the wind tunnel test and the numerical analysis. We investigated the two different option to avoid the damage of fin; i) the adjustment of flare dispenser angle and ii) the change of horizontal fin's shape. For the considering of practical operation of present system, we chose the second option. We estimated the drop safety of external fuel tank with redesigned fin by the wind tunnel experiments.

Experimental study for the pressure drop of R-22 and R-4O7C during the condensation in the micro-fin tubes (마이크로핀관내에서 R-22와 R-4O7C의 응축압력강하 특성에 관한 실험적 연구)

  • Roh, Geon-Sang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.715-722
    • /
    • 2007
  • Experiments were conducted for the investigation of pressure drop inside horizontal micro-fin tubes during the condensation of R-22 and ternary refrigerant. R-407C(HFC-32/125/134a 23/25/62 wt%) as a substitute of R-22. The condenser is a double-tube and counterflow type heat exchanger which is consisted with micro-fin tubes having 60 fins with a length of 4000mm, outer diameter of 9.53mm and fin height of 0.2mm. The mass velocity varied from 102.1 to $301.0kg/(m^2{\cdot}s)$ and inlet quality was fixed as 1.0. From the experimental results. the pressure drop for R-407C was considerably higher than that for R-22. The value of PF(penalty factor) for both of refrigerants was not bigger than the ratio of micro-fin tube area to smooth tube area. Based on the experimental data. correlation was Proposed for the prediction of frictional pressure drop during the condensation of R-22 and R-407C inside horizontal micro-fin tubes.

Natural Convection from a Horisontal Conducting Tube with One Vertical Axial Fin. (단일수직(單一垂直)한 축방향(軸方向)의 핀을 가진 수평전도관(水平傳導管)으로 부터의 자연대류(自然對流))

  • Chung, H.S.;Kwon, S.S.
    • Solar Energy
    • /
    • v.6 no.1
    • /
    • pp.60-69
    • /
    • 1986
  • Two-dimensional finite difference numerical analysis is used to study conjugate natural convection heat transfer from a horizontal conducting tube with one vertical axial fin. By increasing dimensionless fin length ($L_F$), the mean total Nusselt number of the upward fin is slightly less than that of the downward fin at $L_F\;{\le}\;0.18$ and is higher than that of the downward fin at $L_F\;>\;0.18$. However comparing the upward fin and the downward fin with the no fin, the mean total Nusselt numbers of downward fin and upward fin at $L_F=0.30$ are increased approximately 4.01% and 5.51%, respectively. As Rayleigh number, Prandtl number and Biot number increase, the mean total and the mean tube Nusselt numbers are increased, but as wall thickness increases, the mean total and the mean tube Nusselt numbers are decreased. As the fin conduction parameter increases, the mean total Nusselt number is slightly increased because of increasing the mean fin Nusselt number.

  • PDF

Natural convection heat transfer in a horizontal annulus from an inner tube with two vertical fins (2개의 수직휜이 부착된 내관으로부터 환상공간내의 자연대류 열전달)

  • 정태현;정한식;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.654-660
    • /
    • 1991
  • Natural convection heat transfer in a horizontal annulus from an inner tube with two vertical fins has been studied for the effects of dimensionless fin length and Rayleigh number. The maximum local Nusselt number of inner tube was obtained at .theta. = 145.deg. and that of outer cylinder at .theta. = 0.deg. for the case of $l_{F}$=0.3 Local Nusselt number distributions for the lower fins show higher values than that of the upper fins. The mean Nusselt number of inner tube was increased with the values of dimensionless fin length. The mean Nusselt number can be represented in an exponential function of Grashof number at various fin lengths. As compared with experimental and numerical results, isotherms and local Nusselt number show good agreement.t.

The Crack Analysis and Redesign of Horizontal Fin of F-5E/F's External Fuel Tank (F-5E/F 외부 연료탱크 수평 핀 균열 분석 및 재설계)

  • Kang, Chi-Hang;Yoon, Young-In;Jung, Dae-Han
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.4
    • /
    • pp.382-388
    • /
    • 2010
  • In this work the replacement material for magnesium alloy was investigated and an optimized design was suggested for the horizontal fin of a fighter's external fuel tank. For the replacement of magnesium alloy, Aluminum alloy, AL 2034-T351, was selected by considering material properties and its procurement. The strength and fracture toughness properties of AL 2034-T351 are stronger than those of magnesium alloy, but the specific weight of AL 2034-T351 is heavier than that of magnesium alloy by 65%. To meet the allowable limit of C.G. shift in the tank, the design of horizontal fin was optimized by reducing the original shape by 20% and resizing the maximum thickness to 7 mm. From the results of the static and dynamic stress analysis for improving the safety factor of the joint section and the joint hole, the radius of curvature in the aft joint section of the new fin was designed as 8.5mm.