• Title/Summary/Keyword: Hybrid ventilation

Search Result 47, Processing Time 0.024 seconds

A Study on the Operational Strategy for Hybrid Ventilation System in Apartment unit focused on Indoor Air Quality (실내공기질을 고려한 공동주택의 하이브리드 환기 시스템의 운영에 관한 연구)

  • Lee, Yong-Jun;Leigh, Seung-Bok;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.203-210
    • /
    • 2004
  • This dissertation identifies and investigates the possible control modes of hybrid ventilation system in applying to general apartments. It evaluates range of hybrid ventilation control modes in terms of indoor air quality, thermal comfort, and energy consumption in a living room and a kitchen of the $1000m^2$ apartment. The TRNSYS simulation program was used for evaluating the following four ventilation types : A ventilation mode relying on only infiltration for supplying air, A natural ventilation mode considering with weather condition, A hybrid ventilation (natural + mechanical ventilation) mode allowing minimum ventilation with no heat exchange, and a hybrid ventilation mode with heat exchange. This study shows the following results. As temperature being controlled by heating cooling equipments, there is without significant difference in thermal performance among ventilation types. Regarding Indoor Air quality, Indoor air contamination level of the hybrid ventilation case consistently keep the lower levels. The hybrid ventilation modes consume more energy by a 49% as compared to the A ventilation mode relying on only infiltration for supplying air. It is caused by the continuous ventilation for keeping good indoor air quality; the increase of energy consumption can be attributable to the increase of the heating energy. Therefore, the heat exchange between indoor and outdoor air is required during heating season in severe weather conditions. During the cooling seasons, Introducing natural ventilation can achieve energy saving by 40 ~ 45%. Thus, it can be an effective strategies for energy saving. Based on these results, a hybrid ventilation system can be suggested as an effective ventilation strategy for archiving high level of indoor air quality, thermal comfort, and energy consumption.

A Study on the Performance of the Hybrid Ventilation System for Apartment Houses (공동주택의 하이브리드 환기시스템 성능평가 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Kim, Sang-Hee
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.89-96
    • /
    • 2012
  • The purpose of this study was to evaluate the applicability of hybrid ventilation system in apartment housings and present a design method to improve the performance of hybrid ventilation system using the CFD simulation. As the object of CFD simulation, a small apartment houses with area of $51m^2$ and $81m^2$ were selected and evaluated. The test hybrid ventilation system are window frame natural air supply & duct exhaust hybrid system(Hybrid 1) and window frame natural air supply & bathroom and livingroom exhaust hybrid ventilation system(Hybrid 2). To evaluate the ventilation efficiency, we used the locations of diffuser installed for each system as the variables through the CFD simulation. In the case of Hybrid 1, the ventilation efficiency of the exhaust duct diffuser located on the inside room was higher rather than the exhaust duct diffuser located on the entrance. In the case of Hybrid 2, the most efficient system was the system that the diffuser connecting the bathroom static pressure fan is installed on the center of the living room. The ventilation efficiency of the Hybrid 2 in the case of $51m^2$ type was more than 20% of the Hybrid 1. But, The ventilation efficiency of the Hybrid 2 in the case of $84m^2$ type was more than 14% of the Hybrid 1. Therefore, to apply the Hybrid ventilation, a study that considers various variable should be conducted.

A Study on the Performance Evaluation of the Hybrid Ventilation System for Small Apartment Houses (소형 공동주택의 하이브리드 환기시스템 성능실험 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Lee, Jong-Sung;Kim, Sang-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.696-701
    • /
    • 2008
  • From Feb. 2006, the ventilating systems with air exchange rate of over 0.7times/hour are installed at the apartment houses (over 100 units). Installation cost and maintenance cost are very important factors for ventilating system because consumers have to pay the expenses of that system. Especially small apartment needs more considerations because small apartment is comparatively the economically weak part. The purpose of this study is to the performance evaluation of the hybrid ventilation system for small apartment houses. Hybrid system 1 consists of natural ventilation system and duct type exhaust diffusers. Hybrid system 2 has natural ventilation system and toilet exhaust system with static pressure fan. Infiltration of test apartment houses with ventilation system is under 0.1 times/hour. Mean air age of hybrid system 1 is 1.52 hours and hybrid system 2 is 1.42 hours. Mean ventilation effectiveness of hybrid system 2(93%) is higher than that of hybrid system 1(81%).

A Proposal of Hybrid Cooling System Coupled with Radiation Panel Cooling and Natural Ventilation (자연환기와 복사냉방을 병용한 하이브리드 시스템의 제안)

  • 송두삼
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.543-550
    • /
    • 2003
  • In order to saving the energy for HVAC system of buildings, utilization of wind-induced cross ventilation is thought to be promising. However, utilization of natural ventilation alone is not sufficient for maintaining the human thermal-comfort such as in hot and humid regions. A hybrid air conditioning system with a controlled natural ventilation system, or combination of natural ventilation with mechanical air conditioning is thought to overcome the deficiency of wind-driven cross ventilation and to have significant effects on energy reduction. This paper describes a concept of hybrid system and propose a new type of hybrid system using radiational cooling with wind-induced cross ventilation. Moreover, a radiational cooling system is compared with an all-air cooling system. The characteristics of the indoor environment will be examined through CFD (Computational Fluid Dynamics) simulation, which is coupled with a radiation heat transfer simulation and with HVAC control in which the PMV value for the human model in the center of the room is controlled to attain the target value.

A Case Study on the Applied Ventilation System to the High-rise Residential Buildings (초고층 주거용 건축물에 적용된 환기시스템에 관한 사례 연구)

  • Kim, Ok;Kim, Nam-Gyu;Park, Jin-Chul;Rhee, Eon-Ku
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.381-386
    • /
    • 2006
  • This study is to research application cases of domestic ventilation system for developing ventilation system which is energy-saving and improve Indoor Air Quality and to research application possibility of foreign hybrid ventilation system. This is a basic research data of developing ventilation system for energy saying and improving indoor quality which that research the function and a feature of the ventilation system which is applied in five domestic skyscrapers over 30 floors, and research application instances and features of foreign hybrid ventilation system.

  • PDF

A Study of Hybrid Ventilation System applying to an Apartment House (공동주택용 하이브리드 환기설비에 관한 연구)

  • Yi, Seong-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1137-1143
    • /
    • 2006
  • The purpose of this research lays on examining the adequacy of the hybrid ventilation system. The hybrid ventilation system must satisfy the next to be used. Firstly, the cold-draft phenomenon must not exist in the occupied zone. Secondly, the condensation must not happen on the surfaces of vents. Thirdly, the flow of make-up air must be happened in an each space by exhausted air of a rest room and living room. We used an examination and CFD method to verify these. Trough the examination of air-vents, We confirmed that the cold-draft to be induced by make-up air does not happen and could not find the condensation in the limits of outdoor temperature higher than 265K. Through CFD simulation, We confirmed that the rapid temperature change existed only within 0.5m the occupied zone and the flow of air was happened in an each space by only exhausted air in the rest room and living room. Consequently, the hybrid system is possible method to an apartment house.

  • PDF

A Theoretical Study for Stack Effect driven Natural Ventilation System in High-rise Building (고층건물에서 연돌효과를 활용한 자연환기시스템 설계를 위한 이론적 고찰)

  • Yoon, Sung-Min;Seo, Jung-Min;Kim, Yang-Soo;Lee, Joong-Hoon;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.123-129
    • /
    • 2009
  • In these days, the green building movement caused by the energy crisis is increasing, passive design is getting mere and more attention as it provides many possibilities for energy conservation. Moreover, with the increasing social intention for healthy life, the demand for indoor air Quality is increasing in Korea. As result, the ventilation system which can provide the sound outdoor air constantly has been obliged in Korea. So, the hybrid system which using natural power and mechanical power and makes up for the shortage of mechanical and natural ventilation attracts people's attention in Korea. As a hybrid ventilation system, in this study, the stack effect driven hybrid ventilation system in high-rise residential building will be suggested. And in this paper, the theoretical review for hybrid ventilation system suggested in this study will be addressed. Especially, the characteristics of pressure distribution and airflow caused by stack effect in high-rise residential building and the possibility of natural ventilation as results of stack effect will be described.

  • PDF

Analysis of Indoor Air & thermal environment with Hybrid Ventilation system during summer (하계 공동주택 하이브리드 환기시스템 적용에 따른 실내공기 및 열 환경 평가)

  • Kim, Sang-Jin;Kim, Eun-Soo;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.387-392
    • /
    • 2006
  • The recent on indoor air problem has led to many studies on the methods and effects of ventilation for better indoor air quality. Although natural ventilation is the most effective and energy-saving method in residental housings, the small size of openable window has been a problem in high-rise residential buildings to ventilate only through natural ventilation. Consequently, the installation of mechanical ventilation system has been a requirement in residential buildings, and has caused other problems such as increase of energy consumption and SBS. Hybrid ventilation which uses forces of both natural and mechanical power has been introduced to solve the problem of increase in energy consumption with natural ventilation. In this paper, two types of hybrid ventilation systems in residential building were introduced. One type was with natural ventilation through vent grille in the window, and another type was with natural ventilation through ceiling duct while both types used mechanical ventilation system with the outlets. The indoor temperature distribution and pollution density distribution in summer while operating the ceiling air conditioner were analyzed through CFD simulation. In this paper, the optimal location of diffusers to achieve thermal comfort would be proposed.

  • PDF

A study on the Performance of Hybrid ventilation system in High-rise Apartment Houses (초고층 공동주택의 하이브리드 환기시스템의 성능평가에 관한 연구)

  • Kim, Ok;Park, Chang-Bong;Park, Jin-Chul;Kim, Nam-Gyu;Rhee, Eon-Ku
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.113-118
    • /
    • 2007
  • As the economic living standards are higher, the demands for more comfortable living space are also larger. In the response of this requirements, studies for improving indoor air environment have been conducted. In case of newly-built apartment buildings, the standard for the minimum ventilation to improve their indoor air quality was made. This study analysed the experimental results from the mock-up test of the hybrid ventilation system which is composed of natural and mechanical ventilation.

  • PDF

A Prediction of Hybrid Ventilation System Performance in Apartment House (제3종 하이브리드 환기시스템을 적용한 공동주택의 환기성능 예측)

  • Hwang Ji-Hyeon;Oh Chang-Yong;Kim Moo-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.541-548
    • /
    • 2006
  • A hybrid ventilation system was introduced to predict the ventilation performance of the apartments. This ventilation system was composed of the natural supply-air inlet and the forced exhaust-air outlet. Analysis was conducted by CFD technique and was performed on three ventilating flow rates; 30, 60, $120m^3/h$. As the results, residents feel comfortable thermally for $60m^3/h$. In the case of $120m^3/h$, however, residents feel uncomfortable both thermally and in air currents. In this study the energy saving for space heating is also an important factor. In the case of whole region with $180m^3/h$, residents feel comfortable at each region of the model apartment. It is shown that this hybrid ventilation system is possible method for the apartment house.