• Title/Summary/Keyword: Hydrogen Gas in Oil

Search Result 107, Processing Time 0.026 seconds

Sensitivity Enhancement in Measurement of Hydrogen Gas Dissolved in Oil using Gas Collection Time (가스수집시간을 이용한 유중수소가스 측정감도 향상 연구)

  • Heo, Jong-Cheol;Sun, Jong-Ho;Kang, Dong-Sik;Jeong, Joo-Young;Park, Jung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.539-543
    • /
    • 2009
  • This paper describes the sensitivity enhancement in measurement of the hydrogen gas dissolved in oil using gas collection time. On-line gas measurement is a useful for continuous monitoring of power transformer. Recently many studies on hydrogen gas measurement, due to their simplicity and low price, have been done for transformer monitoring. In measurement of the hydrogen gas in oil, the suitable sensitivity and resolution in the desired ranges of the gas concentrations are needed for the reliable monitoring of power transformers. In this study, the sensor output trends were analyzed with the hydrogen gas collection time which means the time to collect the hydrogen gas before reaction of hydrogen gas sensor. It is indicated that the sensor outputs were increased with the increase of hydrogen gas collection times at the same hydrogen gas concentrations.

Measurement Technology of the Dissolved Hydrogen Gas Due to Partial Discharge in Oil using Gas Sensor (가스센서를 이용한 부분방전특성에 따른 유중수소가스 측정연구)

  • Heo, Jong-Cheol;Sun, Jong-Ho;Kang, Dong-Sik;Jeong, Joo-Young;Choo, Y.B.;Park, Jung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1784-1789
    • /
    • 2009
  • This paper describes the measurement technology of the dissolved hydrogen gas due to partial discharge in oil using gas sensor. For higher resolution and less error in measurement of the dissolved hydrogen gas in oil, the sensor outputs with ambient temperature which affect the sensor output characteristics should be considered. The sensor output trends with ambient temperature and the properties of the dissolved hydrogen gas in oil with partial discharge characteristic were analyzed through the test results. It was indicated that the sensor peak and the base voltage with measuring time were affected by ambient temperature and the measurement errors of the sensor output by temperature were reduced by using the difference between the peak and the base voltage rather than just the peak voltage. In addition, the hydrogen gas sensor outputs were increased with the increase of partial discharge energy.

Gas Detector for Hydrogen Dissolved in Transformer Oil

  • Seo Ho-Joon;Hwang Kyu-Hyun;Rhie Dong-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.2
    • /
    • pp.72-75
    • /
    • 2005
  • In oil-filled equipment such as transformers, partial discharge or local overheating will precede a final shutdown. Accompanied with such problems is a decomposition of insulating material into gases, which are dissolved into the transformer oil. The gases dissolved in oil can be separated with some membranes based on the differences in permeability of membranes to different gases. This paper discuss the permeability characteristics of several membranes for separation hydrogen gas in oil. With result of this paper, it may become possible to detect fault-related gases from transformer oil and predict incipient failures in the

Detection of Hydrogen Gas Dissolved in Insulation Oil Based on Palladium-coated Fiber Bragg Grating (팔라듐이 코팅된 광섬유 격자를 이용한 절연유속의 용존 수소가스 검출)

  • Kim, Kwang Taek;Choi, Nu ri;Baik, Se-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.403-406
    • /
    • 2018
  • We have investigated a fiber-optic sensor for detecting the hydrogen gas dissolved in insulation oil based on a palladium (Pd)-coated fiber Bragg grating (FBG). As the palladium absorbs the hydrogen gas dissolved in the insulation oil, its volume expands and the Bragg wavelength shifts to a longer wavelength. The experimental results showed that the Bragg wavelength of FBG increased to 70 nm when the concentration of hydrogen dissolved in the insulation oil was 409 ppm.

Direct Synthesis of Dimethyl Ether From Syngas in Slurry Phase Reactor (액상 슬러리 반응기에서 합성가스로부터 DME 직접 제조)

  • Hwang, Gap-Jin;Kim, Jung-Min;Lee, Sang-Ho;Park, Chu-Sik;Kim, Young-Ho;Kim, Jong-Won
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.2
    • /
    • pp.119-128
    • /
    • 2004
  • DME(Dimethyl Ether) was directly produced from the synthesis gas using the slurry phase reactor. The catalyst for DME production prepared two types (A type; Cu:Zn:Al=57:33:10, B type; Cu:Zn:Al=40:45:15, molar ratio). It was evaluated for the effect of the reaction medium oil using the small size slurry phase reactor. DME production yield and the methanol selectivity decreased in the order: n-hexadecane oil> mineral oil> therminol oil. The long-term test of DME production was carried out using A and B type catalyst, and n-hexadecane oil and mineral oil, respectively. It was confirmed that the use of A type for the catalyst and n-hexadecane for the reaction medium oil was very useful for the viewpoint of the DME production form the synthesis gas.

A Numerical Analysis on a Dependence of Hydrogen Diaphragm Compressor Performance on Hydraulic Oil Conditions (오일부 운전조건 변화에 따른 수소용 다이어프램 압축기의 성능예측에 대한 수치해석)

  • Park, Hyun-Woo;Shin, Young-Il;Lee, Young-Jun;Song, Ju-Hun;Chang, Young-June;Jeon, Chung-Hwan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.6
    • /
    • pp.471-478
    • /
    • 2009
  • The specific some types of compressors are appropriate for a use in hydrogen gas station. Metal diaphragm type of hydrogen compressor is one of them, which can satisfy the critical requirements of maintaining gas purity and producing high pressure over 850 bar. The objective of this study is to investigate an characteristics of compression through two-way Fluid-Structure-Interaction (FSI) analysis as bulk modulus and initial volume of oil independently varies. Deflection of diaphragm, oil density, gas and oil pressure were analyzed during a certain period of compression process. According to the analysis results, bulk modulus and initial volume remarkably affected deflection of diaphragm, oil density, gas and oil pressure. The highest gas pressure were attained with the highest bulk modulus of $7e^9\;N/m^2$ and the lowest initial oil volume of 80 cc.

Numerical Analysis on a Dependence of Hydrogen Diaphragm Compressor Performance on Oil Characteristics (수소용 다이어프램 압축기의 작동유 특성에 따른 수치해석)

  • Park, Hyun-Woo;Shin, Young-Il;Lee, Young-Jun;Song, Ju-Hun;Chang, Young-June;Jeon, Chung-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.787-790
    • /
    • 2009
  • There are several types of compressors which are appropriate for hydrogen gas station. Metal diaphragm type of hydrogen compressor is the one of them, a use in which satisfies the requirements of maintaining gas purity and producing high pressure over 700 bar. The objective of this study is to investigate an characteristics of compression as bulk modulus of oil varies. Three cases of bulk modulus ranging from $2{\times}10^9$, $4.52{\times}10^9$ and $7{\times}10^9$ were studied through FSI (Fluid Structure Interaction) analysis. Gas pressure, oil pressure and deflection degree of diaphragm were analysed during a certain period of compression process. Highest pressure and deflection were found in the condition of high bulk modulus of $7{\times}10^9$.

  • PDF

Utilization of alternative marine fuels for gas turbine power plant onboard ships

  • El Gohary, M. Morsy;Seddiek, Ibrahim Sadek
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.5 no.1
    • /
    • pp.21-32
    • /
    • 2013
  • Marine transportation industry is undergoing a number of problems. Some of these problems are associated with conventional marine fuel-oils. Many researchers have showed that fuel-oil is considered as the main component that causes both environmental and economic problems, especially with the continuous rising of fuel cost. This paper investigates the capability of using natural gas and hydrogen as alternative fuel instead of diesel oil for marine gas turbine, the effect of the alternative fuel on gas turbine thermodynamic performance and the employed mathematical model. The results showed that since the natural gas is categorized as hydrocarbon fuel, the thermodynamic performance of the gas turbine cycle using the natural gas was found to be close to the diesel case performance. The gas turbine thermal efficiency was found to be 1% less in the case of hydrogen compared to the original case of diesel.

Application of nanoparticles in extending the life of oil and gas transmission pipeline

  • Yunye, Liu;Hai, Zhu;Jianfeng, Niu
    • Structural Engineering and Mechanics
    • /
    • v.84 no.6
    • /
    • pp.733-741
    • /
    • 2022
  • The amount of natural gas that is used on a worldwide scale is continuously going up. Natural gas and acidic components, such as hydrogen sulfide and carbon dioxide, cause significant corrosion damage to transmission lines and equipment in various quantities. One of the fundamental processes in natural gas processing is the separation of acid gases, among which the safety and environmental needs due to the high toxicity of hydrogen sulfide and also to prevent wear and corrosion of pipelines and gas transmission and distribution equipment, the necessity of sulfide separation Hydrogen is more essential than carbon dioxide and other compounds. Given this problem's significance, this endeavor aims to extend the lifespan of the transmission lines' pipes for gas and oil. Zinc oxide nanoparticles made from the environmentally friendly source of Allium scabriscapum have been employed to accomplish this crucial purpose. This is a simple, safe and cheap synthesis method compared to other methods, especially chemical methods. The formation of zinc oxide nanoparticles was shown by forming an absorption peak at a wavelength of about 355 nm using a spectrophotometric device and an X-ray diffraction pattern. The size and morphology of synthesized nanoparticles were determined by scanning and transmission electron microscope, and the range of size changes of nanoparticles was determined by dynamic light scattering device.

Influence of Filler Particle Size on Behaviour of EPDM Rubber for Fuel Cell Vehicle Application under High-Pressure Hydrogen Environment (수소전기차용 EPDM 고무의 충전재 입자 크기별 고압 수소 환경에서의 거동 연구)

  • KIM, KEEJUNG;JEON, HYEONG-RYEOL;KANG, YOUNG-IM;KIM, WANJIN;YEOM, JIWOONG;CHOI, SUNG-JOON;CHO, SUNGMIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.5
    • /
    • pp.453-458
    • /
    • 2020
  • In this study, ethylene-propylene-diene monomer (EPDM) rubbers reinforced with various particle size of carbon black were prepared and tested. We followed recently published CSA/ANSI CHMC2 standard "the test methods for evaluating material compatibility in compressed hydrogen applications-polyemr". Measurement of change in hardness, tensile strength and volume were performed after exposure to maximum operating pressure, 87.5 MPa, for 168 hours (1 week). Once EPDM was exposed to high-pressure hydrogen, the samples experience volume increase and degradation of the physical properties. Also, after the dissolved hydrogen was fully eliminated from the specimens, the hardness and the tensile properties were not recovered. The rubber reinforced with smaller sizes of carbon black particles showed less volume expansion and decrease of physical properties. As a result, smaller particle size of carbon black filler led to more resistance to high-pressure hydrogen.