• Title/Summary/Keyword: Hygroscopic property

Search Result 35, Processing Time 0.029 seconds

Wood Quality and Growth of Quercus rubra in Korea - Water absorption, Hygroscopic property - (루브라참나무의 생장과 재질 - 흡수량, 흡습성 -)

  • Park, Kang-Sik;Kim, Byung-Ro
    • Journal of the Korea Furniture Society
    • /
    • v.27 no.2
    • /
    • pp.91-95
    • /
    • 2016
  • This study was conducted to investigate the relationship between water absorption (or hygroscopic property) and growth rate of rubra oak (Quercus rubra) from 5 different origins of seed (Carleton, Simcoe, Chatham, Bancroft, Unknown). Water absorption at cross section of Quercus rubra was $0.43{\sim}0.92g/cm^2$ and the property was not related with growth rate. Overall equilibrium moisture content of rubra oak were 11.35~11.56% and 15.15~15.83% at $40^{\circ}C$ with 75% and 90% relative humidities, respectively. There was no relationship between growth rate and moisture content(hygroscopy) in rubra oak. Based on the results, Rubra oak can be classified as a low hygroscopic wood grade, and thus might be a good raw material for furniture productions owing to its superior dimensional stability.

Hygroscopic Property of Heat Treated Yellow Poplar (Liriodendron tulipifera) Wood

  • CHANG, Yoon-Seong;HAN, Yeonjung;EOM, Chang-Deuk;CHUN, Sangjin;YEO, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.6
    • /
    • pp.761-769
    • /
    • 2019
  • In modern societies, people spend most of their time indoors and the temperature and humidity controlled by electrical appliances have a considerable effect on their emotions and health. However, improper operation of the artificial facilities frequently creates substances that are harmful to our body. The importance of controlling the natural humidity of interior materials has therefore attracted significant attention. This study was aimed at quantifying the hygroscopic property of some interior finishing wooden materials. Dried and heat-treated yellow poplar (Liriodendron tulipifera) lumbers, oriented strand board, and plywood were selected for this experiment. The moisture adsorption and desorption rates of wooden materials were measured (ISO 24353). Furthermore, the effects of morphological, physical and chemical factors, such as surface microstructure, roughness, and functional groups, on the hygroscopicity were evaluated. The results of this study should contribute to improved accuracy of hygroscopic-property assessments performed on wooden interior materials.

Hygroscopic Property, Leaching Resistance and Metal Corrosive Efficacy of Wood Treated with Fire Retardants

  • Son, Dong Won;Kang, Mee Ran;Hwang, Won Joung;Lee, Hyun Mi;Park, Sang Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.2
    • /
    • pp.157-162
    • /
    • 2014
  • This study was conducted to examine the functionality of the fire retardant treated wood. The hygroscopic property, leaching resistance, metal corrosive efficacy and gas toxicity of retardant treated wood were analyzed. Sodium silicate was penetrated to the wood for making fire retardant treated wood. The subsequent treatment agents such as boric acid, ammonium borate, di-ammonium phosphate were treated after sodium silicate treatment due to fixation. As results for the test, the leaching resist was improved by subsequent treatment. The fire retardant combination such as sodium silicate, boric acid and di-ammonium phosphate showed high hygroscopic property, metal corrosive efficacy. The gas toxicity was also satisfied KS standard.

An Experimental Study on Non-hygroscopic Propertiy of PAG and POE Oils for a $CO_2$ Refrigeration System ($CO_2$ 냉동시스템용 PAG오일과 POE오일의 항흡습성에 관한 실험적 연구)

  • Lee, Sung-Kwang;Kang, Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.388-393
    • /
    • 2008
  • This study has been conducted to select the suitable refrigeration oil for a $CO_2$ refrigeration system. Non-hygroscopic property of refrigeration oils is one of the most important properties for refrigeration oils. PAG and POE oils are considered as test oils in this study. Transient variation of water content of PAG and POE oils was measured for 3 different vessels in the environmental conditions, such as in the range of temperature $25^{\circ}C$ to $40^{\circ}C$ and relative humidity 40% to 85%. The results obtained that water content of both POE and PAG is increased with an increase in the contact area with ambient for 3 different vessels. It is also found that water content of both POE and PAG is increased as the ambient temperature and relative humidity is increased. Non-hygroscopic property of POE oil is found to be much superior than that of PAG oil.

Development of diverse fluorides source for applicable F-18 radiofluorination method

  • Park, Su Hong;Kim, Dong Wook
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.2 no.1
    • /
    • pp.17-21
    • /
    • 2016
  • Alkali metal fluoride sources (MFs) such as potassium fluoride (KF) have been widely used as a fluoride source in the nucleophilic displacement reaction. However, they have low solubility and nucleophilicity in most of the organic solvents. Bulky fluoride sources such as tetrabutylammonium fluoride (TBAF) were substituted for MFs to improve these properties. However, hygroscopic property of TBAF makes it less convenient for handling as well as its strong basic property can make the side-reaction occur. Recently, novel fluoride sources have been developed to solve these problems. In this paper, we would like to introduce coordinated fluoride sources as a new fluoride sources such as tetrabutylammonium tetra(t-butyl alcohol)-coordinated fluoride, crown ether metal complex fluoride, and various bulky alcohols coordinated fluoride complexes. In particular, bulky alcohol coordinated fluoride source could generated by the controlled hydrogen-bonded of fluoride with alcohols and these fluoride sources have better stability and reactivity with showing low hygroscopic property. The study of these fluoride sources will help to understand the characteristic of [$^{18}F$]fluoride for increasing the radiochemical yield in the [$^{18}F$]radiofluorination.

Thermal and Hygroscopic Properties of Indoor Particulate Matter Collected on an Underground Subway Platform

  • Ma, Chang-Jin;Lee, Kyoung-Bin;Zhang, Daizhou;Yamamoto, Mariko;Kim, Shin-Do
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • In order to clarify the thermal and hygroscopic properties of indoor particulate matter (PM) in a semiclosed subway space, which is critically important for understanding of the distinctive particle formation processes as well as the assessment of their health effects, the size-resolved PMs (i.e., $PM_{2.5}$ and $PM_{10-2.5}$) were intensively collected on the platform of Miasageori station on the Seoul Subway Line-4. The elemental concentrations in soluble and insoluble fractions were determined by PIXE from the bulkily pretreated $PM_{2.5}$. The thermal and hygroscopic characteristics of individual particles were investigated via a combination of the unique pretreatment techniques (i.e., the high-temperature rapid thermal process and the water dialysis) and SEM-EDX analysis. Iron and calcium were unequaled in insoluble and soluble $PM_{2.5}$ fractions, respectively, with overwhelming concentration. The SEM-EDX's elemental net-counts for the pre- and post-pyrolyzed PMs newly suggest that magnesium and several elements (i.e., silica, aluminum, and calcium) may be readily involved in the newly generated subway fine PM by a high-temperature thermal processing when trains are breaking and starting. Through the water dialysis technique, it turned out that calcium has meaningful amount of water soluble fraction. Furthermore, the concentrations of the counter-ions associated with the calcium in subway $PM_{10-2.5}$ were theoretically estimated.

A Study on the Film Performance by Physical Properties of Gelatin(Glue) in Dancheong (젤라틴(아교)의 물성에 따른 단청 도막의 성능비교 연구)

  • Park, Ji Hye;Jeong, Seon Hye;Kim, Ik Joo;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.29 no.1
    • /
    • pp.25-33
    • /
    • 2013
  • This study aims to investigate the film performance by physical properties of glue and gelatin in traditional paint(Dancheong). To do this, homemade, commercial glue and gelatin was selected and evaluated water reaction and weatherproof. The result, the highest gel strength, gelatin was better than acrylic acid ester resin, when compared with hygroscopic property and adhesive property. And that was better than in any others, when compared with water-proofing.

Synthesis of the Low-Hygroscopic Polyimide for 2-Layer Flexible Copper Clad Laminate (2층 연성동박적층판용 저흡습 폴리이미드의 합성)

  • Kim, W.;Park, S.J.;Baek, J.O.;Gong, H.J.;Ahn, B.H.
    • Elastomers and Composites
    • /
    • v.43 no.2
    • /
    • pp.82-87
    • /
    • 2008
  • In this study, nine kinds of polyimides were synthesized from 1,2,4,5-benzenetetracarboxylic dianhydride (PMDA), 4,4'-(4,4'-isopropylidenediphenoxy)bis(phthalic anhydride) (BPADA), m-pheny lenediamine (m-PDA) and 4,4'-oxydianiline (ODA) by controlling molar ratio of monomers. Synthesized polyimides were used as insulator films for 2-layer Flexible Copper Clad Laminate(FCCL) which were manufactured by the casting method. Glass transition temperature and thermal degradation temperature for 5% weight loss of the polyimide film were improved by increasing contents of m-PDA and PMDA, respectively. Water absorption of polyimide film was reduced by increasing contents of ODA and BPADA which have relatively long structure, respectively. Peel strength of 2-layer FCCL was improved by increasing contents of ODA and BPADA.

Physical Properties of Linerboard and Corrugated Fiberboard at the Cyclic Condition of Low Humidity (저습도 사이클 조건에서의 라이너지와 골판지의 물성)

  • Youn, Hye-Jung;Lee, Hak-Lae;Chin, Seong-Min;Choi, Ik-Sun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.2 s.120
    • /
    • pp.38-44
    • /
    • 2007
  • The hygroscopic property of paper is important for convertability and end use performance. When the board and corrugated fiberboard are exposed to low relative humidity, a trouble of score (or crease) cracking could occur. In this study, we evaluated the moisture content and mechanical properties of linerboard and corrugated board at the cyclic condition of low humidity to prevent a score crack trouble. As the relative humidity decreased from 50% to 38% and 25%, the moisture content of linerboard decreased about 7% to 6% and 4%. At low humidity, most of mechanical properties were improved except for strain. The linerboard exposed at 25% RH showed a remarkable reduction of strain by 11%. At the same relative humidity, linerboard and corrugated fiberboard showed the different property values depending on moisture hysteresis.