• Title/Summary/Keyword: I%2FI analysis

Search Result 17, Processing Time 0.037 seconds

Cross-Technology Localization: Leveraging Commodity WiFi to Localize Non-WiFi Device

  • Zhang, Dian;Zhang, Rujun;Guo, Haizhou;Xiang, Peng;Guo, Xiaonan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.11
    • /
    • pp.3950-3969
    • /
    • 2021
  • Radio Frequency (RF)-based indoor localization technologies play significant roles in various Internet of Things (IoT) services (e.g., location-based service). Most such technologies require that all the devices comply with a specified technology (e.g., WiFi, ZigBee, and Bluetooth). However, this requirement limits its application scenarios in today's IoT context where multiple devices complied with different standards coexist in a shared environment. To bridge the gap, in this paper, we propose a cross-technology localization approach, which is able to localize target nodes using a different type of devices. Specifically, the proposed framework reuses the existing WiFi infrastructure without introducing additional cost to localize Non-WiFi device (i.e., ZigBee). The key idea is to leverage the interference between devices that share the same operating frequency (e.g., 2.4GHz). Such interference exhibits unique patterns that depend on the target device's location, thus it can be leveraged for cross-technology localization. The proposed framework uses Principal Components Analysis (PCA) to extract salient features of the received WiFi signals, and leverages Dynamic Time Warping (DTW), Gradient Boosting Regression Tree (GBRT) to improve the robustness of our system. We conduct experiments in real scenario and investigate the impact of different factors. Experimental results show that the average localization accuracy of our prototype can reach 1.54m, which demonstrates a promising direction of building cross-technology technologies to fulfill the needs of modern IoT context.

Wi-Fi-Based Low-Complexity Floor Number Determination Method Based for Multistory Buildings (다층 건물을 위한 Wi-Fi 기반의 저 복잡도 층간 위치 측위 기법)

  • Shi, Jian;Li, Xiang;Jung, Honggyu;Kim, Jinoh;Shin, Yoan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.2
    • /
    • pp.149-156
    • /
    • 2014
  • Floor number determination has attracted considerable attention because many applications require accurate floor number information for providing better localization services in multistory buildings. This paper describes a Wi-Fi-based, low-complexity floor number determination method for multistory buildings. In our scheme, with the exception of floor ID and received signal strength of each WAP, detailed information on the wireless access point (WAP) coordinates is not needed. The multi-wall-floor model is used for the simulation and analysis. The simulation results show that the floor determination accuracy is nearly 100 given an adequate deployment density of WAPs on each floor. The results also show that the proposed method provides a good estimate of floor number even when only a few WAPs are implemented on each floor. Specifically, the proposed method can work under extreme conditions, i.e., where there are no WAPs on a floor.

The Design and Implementation of Network Measurement System for Mobile Platforms (모바일 플랫폼을 위한 네트워크 환경 측정 시스템 설계 및 구현)

  • Kim, Kanghee;Yeo, Jinjoo;Kim, JinHyuk;Choi, SangBang
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.35-46
    • /
    • 2013
  • As a rapid increase of mobile network usage, many studies on solution for network traffic's demand problem have been done. Especially network environment measurement area provides basis for solving network traffic's demand problem by finding causes of problems through accurate network analysis. However, as increase of demand for smartphone, we should consider effects of mobile platform's property measuring mobile network. In this paper, we design a network traffic measurement system considering mobile platform. Through the information from packets, this system calculates packet transmission delay and throughput. We minimize computation cost required for a mobile device that is a client in this system. When fully using network resources, we found that Wi-Fi has shorter transmission delay, higher maximum throughput and lower loss rate than 3G, Android has shorter transmission delay and higher maximum throughput than iOS, and UDP has longer transmission delay and higher maximum throughput through this system.

Study on the Inclusion Behavior of Sulfobutylether-β-Cyclodextrin with Perphenazine by Flow Injection Chemiluminescence

  • Shen, Minxia;Lv, Hairu;Song, Zhenghua
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3199-3205
    • /
    • 2013
  • The inclusion behavior of sulfobutylether-${\beta}$-cyclodextrin (SBE-${\beta}$-CD) with perphenazine (PPH) was first studied by flow injection (FI)-chemiluminescence (CL) analysis with proposed $lg[(I_0-I_s)/I_s]=lgK_{P-CD}+nlg[C_{PPH}]$ model and molecular docking. Results showed that a 1:1 complex of SBE-${\beta}$-CD/PPH could online form, with the formation constant $K_{P-CD}$ of $2.57{\times}10^7Lmol^{-1}$ at 298 K. The thermodynamic parameters showed that the inclusion behavior of SBE-${\beta}$-CD/PPH was a spontaneous process by hydrophobic interaction. The molecular docking results revealed PPH entered into the larger cavity of SBE-${\beta}$-CD with two hydrogen bonds. Based on the linear relationship of the decrement of luminol/SBE-${\beta}$-CD/PPH CL intensity against the logarithm of PPH concentration ranging from 0.03 to 30.0 ng $mL^{-1}$, the present FI-CL analysis using luminol/SBE-${\beta}$-CD/PPH system was successfully applied to PPH determination in biological fluids and tablets with recoveries from 94.5 to 105.6% and RSDs less than 2.6% (n = 5).

A STUDY ON THE RADIOPACITY OF GLASS IONOMER CEMENTS (Glass Ionomer Cement의 방사선 불투과성에 관한 연구)

  • Park, Soo-Kyeong;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.122-132
    • /
    • 1993
  • The aim of this study was to investigate the level of radiopacity of glass ionomer cements and to determine the optimum level of radiopacity that is the most compatible with the radiographic diagnosis of secondary caries. The experiments were performed in two parts. In the first part, the radiopacities of 9 glass ionomer cements (FI, FII, FI-LC, FII-LC, SI, SII, Vit, B-VLC, AC) and base materials(Ultra-Blend, Zinc phoaphate cements, Cavitec, Dycal) were measured by densitometer. Then all experimental materials were divided into 5 groups based on the level of radiopacity of enamel and dentin. In the second part, class III cavities with or without secondary caries were prepared in extracted anterior teeth. The representative materials of each group with different radiopacities were inserted into each cavity. The radiographs were interpreted by 15 dentists and seconsary caries were diagnosed according to a five-point confidence rating. Sensitivity and ROC analysis were used to compare observer performance. The following results were obtained : 1. The radipacity of glass ionomer cements varied between 1.111mm Al and 6.011mm Al equivalent. 2. Among experimental materials, three materials in group I had lower radiopacity than that of dentin. The radiopacity of two materials in group II slightly exeeded that of dentin. Three materials in group III had slightly lower radiopacity than that on enamel. The radiopacity of one material in group W was slightly higher than that of enamel. Four materals in group V had the radiopacity that exeeded over 2.0mm AI equivalent to that of enamel. 3. The group IV was the highest for sensitivity and the group V was the highest for ROC area. However, no significant differences were obtained among group II, III, IV and V (P<0.05) but only group I was significantly lower(P<0.01). 4. In comparison with the observer performance for the radiographic diagnosis of secondary caries, the group II, III, IV, and V were superior to the group I (P<0.01). And so the optimum level of radiopacity to detect the secondary caries was the radiopacity that is higher than that of dentin.

  • PDF

Process Control Analysis for Efficient Production Management of Customized Baseball Uniforms (맞춤형 야구복의 효율적 생산관리를 위한 공정관리 분석)

  • Choi, Kueng-Mi;Hwang, Hyun-Jung;Jun, Jung-Il;Park, Yong-Soo
    • Fashion & Textile Research Journal
    • /
    • v.14 no.4
    • /
    • pp.597-606
    • /
    • 2012
  • To increase the productivity and product quality of customized baseball jerseys, this study developed a multi-variable system for a production process that efficiently controls diverse production management factors. The working time was measured through the establishment of a standard process where skilled workers and Chinese factory workers manufactured 5 sets of the same basic design jerseys. Based on the measured working time (1,136 seconds/per unit), the multi-variable process control system was developed, where hourly production management is possible according to the involved workers and equipment types. Each process was assigned accoding to the production management factors for a total of 28 standard processes. The processes were developed based on consideration of work characteristics according to the order of needlework of open-type set baseball jerseys with sleeves(the basic design of baseball jerseys)to result in a customized production system structure that could be set up with multi-variables. As a result, a total 12 types of systems were developed in consideration of the personnel involved and the number of equipments. The optimal production management system (with the highest efficiency compared to the number of workers)was A-2, B-1, C-1. D-2, E-2, F-1, and G-1. This system had extremely high efficiency and showed 99% assignment efficiency for the 7-person team. Though not optimal, possible process assignment for each working personnel is proposed as a reserve process in case work modification is inevitable due to malfunctions and the absence of equipments.

Using the Android Communication Module and Sensor the Movement Method Output System of According to Accelerated (안드로이드 통신모듈 및 센서를 이용한 가속에 따른 이동방법 산출 시스템)

  • Park, Sung-Hyun;Jang, Ki-Man;Yuk, Jung-Soo;Huh, Tae-Sang;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.672-674
    • /
    • 2014
  • Mobile communication technology was one of the GPS technology, SmartPhone, Tablet PC is equipped with a GPS. So the user has a navigation, speed and his position to send and receive a variety of information. Therefore, in this paper, Mobile devices, GPS, Wi-Fi and mobile networks, and the communication module uses algorithms to analysis of acceleration and output, the user is currently using the system to find out the kind of transportation. This is the users who are using a particular transport unnecessary information and apply it to different areas do not think I will be able to.

  • PDF

Analysis on the EMC evaluating method for applying wireless communications in NPP (원전 내 무선통신 적용에 대한 전자파 적합성 평가방법 분석)

  • Kang, SeungSeok;Lim, Tae Heung;Choo, Jaeyul;Kim, HyungTae;Kim, DaeHee;Byun, Gangil;Park, Jong Eon;Lee, Jun-Yong;Choo, Hosung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.12
    • /
    • pp.2221-2231
    • /
    • 2017
  • In this paper, we surveyed previous cases, network protocols (such as Wi-Fi, Zigbee, Z-wave, and WirelessHart) and propagation characteristics on the application of maintaining equipments for instrumentation and control (I&C) using wireless communication techniques inside the nuclear power plant (NPP). In addition, we compared and analyzed the difference of detailed regulations with respect to the electromagnetic interference (EMI) and radio frequency interference (RFI) in the Regulatory Guide 1.180 rev. 1 (RG. 1.180) for adopting the wireless communication techniques inside the NPP, and other regulations, such as MIL-STD 461E and IEC 61000-4, that are recognized in the KINS/RG-N03.09 (Rev. 2). Furthermore, we investigated evaluating factors about electromagnetic properties by considering indoor environments, wave scattering, shielding effectiveness, and the indoor wave attenuation model that were not included in the current electromagnetic compatibility regulation.

Effect of Inhaled Nitric Oxide on Hemodynamics, Gas Exchange and Pulmonary Inflammation in Newborn Piglets with Escherichia coli Induced Septic Lungs (패혈성 폐가 유도된 신생자돈에서 외인성 Nitric Oxide 흡입의 혈역학, 가스교환 및 폐 염증에 대한 효과)

  • Chang, Yun Sil;Ko, Sun Young;Park, Won Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.8
    • /
    • pp.777-783
    • /
    • 2003
  • Purpose : The aim of this study was to evaluate the effect of inhaled nitric oxide(iNO) on gas exchange, hemodynamics and pulmonary inflammation in newborn piglets with E. coli induced septic lung. Methods : Twenty three instrumented and ventilated piglets were randomized into three groups : CON(n=6), PCON(n=9), and PNO(n=8). In the piglets of the PCON and PNO groups, E. coli septic lung was induced by endotracheal instillation of E. coli. Ten ppm iNO was given continuously in the PNO group after endotracheal instillation of E. coli. All animals were mechanically ventilated for six hour with a peak inspiratory pressure of 30 $cmH_2O$, frequency of 25 breaths/min, $FiO_2$ 1.0 and a positive end-expiratory pressure of 4 $cmH_2O$. All measurements were made at one hour intervals during the experiment. At the end of the experiment, lung tissue was harvested for the analysis of myeloperoxidase activity, indicative of lung inflammation. Results : All piglets with pulmonary instillation of E. coli developed E. coli sepsis. Piglets in the PCON group developed progresseve pulmonry hypertension, hypoxemia and hypercarbia compared to the CON group due to increased pulmonary vascular resistance, intrapulmonary shunt fraction and physiologic dead space fraction. iNO did not reverse pulmonary hypertension in the PNO group. However iNO significantly improved oxygenation, which was attributed to marked improvement of venous admixture and partial attenuation of increase in dead space fraction. Increased myeloperoxidase activity in PCON compared to CON was significantly attenuated in PNO. Conclusion : iNO improves oxygenation and lung inflammation in newborn piglets with E. coli induced septic lung.