• Title/Summary/Keyword: ICP27

Search Result 133, Processing Time 0.03 seconds

HSV-1 ICP27 represses NF-κB activity by regulating Daxx sumoylation

  • Kim, Ji Ae;Choi, Mi Sun;Min, Jung Sun;Kang, Inho;Oh, Jeongho;Kim, Jin Chul;Ahn, Jeong Keun
    • BMB Reports
    • /
    • v.50 no.5
    • /
    • pp.275-280
    • /
    • 2017
  • Herpes simplex virus type 1 ICP27 is a multifunctional protein responsible for viral replication, late gene expression, and reactivation from latency. ICP27 interacts with various cellular proteins, including Daxx. However, the role of interaction between ICP27 and Daxx is largely unknown. Since Daxx is known to repress $NF-{\kappa}B$ activity, there is a possibility that ICP27 may influence the inhibitory effect of Daxx on $NF-{\kappa}B$ activity. In this study, we tested whether ICP27 affects the $NF-{\kappa}B$ activity through its interaction with Daxx. Interestingly, ICP27 enhanced the Daxx-mediated repression of $NF-{\kappa}B$ activity. In addition, we found that sumoylation of Daxx regulates its interaction with p65. ICP27 binds to Daxx, inhibits Daxx sumoylation, and enhances p65 deacetylation induced by Daxx. Consequently, ICP27 represses the $NF-{\kappa}B$ activity, by elevating the inhibitory effect of Daxx on $NF-{\kappa}B$ activity through desumoylation of Daxx.

HSV-1 ICP27 induces apoptosis by promoting Bax translocation to mitochondria through interacting with 14-3-3θ

  • Kim, Ji Ae;Kim, Jin Chul;Min, Jung Sun;Kang, Inho;Oh, Jeongho;Ahn, Jeong Keun
    • BMB Reports
    • /
    • v.50 no.5
    • /
    • pp.257-262
    • /
    • 2017
  • The subcellular localization of Bax plays a crucial role during apoptosis. In response to apoptotic stimuli, Bax translocates from the cytoplasm to the mitochondria, where it promotes the release of cytochrome c to the cytoplasm. In cells infected with HSV-1, apoptosis is triggered or blocked by diverse mechanisms. In this study, we demonstrate how HSV-1 ICP27 induces apoptosis and modulates mitochondrial membrane potential in HEK 293T cells. We found that ICP27 interacts with $14-3-3{\theta}$ which sequesters Bax to the cytoplasm. In addition, ICP27 promotes the translocation of Bax to the mitochondria by inhibiting the interaction between $14-3-3{\theta}$ and Bax. Our findings may provide a novel apoptotic regulatory pathway induced by ICP27 during HSV-1 infection.

CCP and ICP Combination Impedance Matching Device for Uniformity Improvement of Semiconductor Plasma Etching System (반도체 플라즈마 식각 시스템의 균일도 향상을 위한 CCP와 ICP 결합 임피던스정합 장치)

  • Jung, Doo-Yong;Nam, Chang-Woo;Lee, Jong-Ho;Choi, Dae-Kyu;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.274-281
    • /
    • 2010
  • This paper proposes a DFPS (Dual Frequency Power Source) impedance matching device for uniformity improvement of a semiconductor plasma etching system. The DFPS consists of two parts for safe plasma processing on large-area substrates. The first part is an ICP (Inductively Coupled Plasma) for high integration by using ferrite core. The second part is a CCP (Capacitive Coupled Plasma) to control uniformity of whole cells. Proposed DFPS can achieve high productivity improvement required for semiconductor equipment industry. The proposed plasma system is analyzed, simulated and experimentally verified with a matching equipment at 27.12MHz and 400kHz.

Determination of boron in steel by HNO3-NH4HF2 digestion and ICP-MS (질산-이플루오린화암모늄 분해 및 ICP-MS에 의한 철강 중 붕소 정량에 관한 연구)

  • Choi, Won Myung;Eum, Chul Hun;Park, Ilyong
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.352-356
    • /
    • 2014
  • Various studies have been done to improve the properties of the steel by adding boron to the steel. Some studies have reported on the analysis of the boron in steel by AAS (atomic absorption spectrometry), ICP-OES(inductively coupled plasma-optical emission spectrometry), ICP-MS (inductively coupled plasma/mass spectrometry). The volatile loss of boron of steel in sample digestion and the separation procedure for avoiding matrix effect by high concentration of iron are difficulties for determination of boron in steel. The method to determine boron in steel by ICP-MS was developed without volatilization of boron in sample digestion step with $HNO_3-NH_4HF_2$ digestion method, and the additional separation process for avoiding matrix effect. Complete decomposition of steel with $HNO_3-NH_4HF_2$ digestion method, and boron determination by ICP-MS in the matrix of high concentration of iron were possible. Quantitative recoveries of boron in certified standard steel by new method in this study were 103 to 111%, and the relative standard deviation is less than 5%. The method detection limit was $1.17{\mu}g/g$.

The Effect for Intracranial Pressure during Laryngoscopy and Endotracheal Intubation (기관내삽관이 뇌압변동에 미치는 영향)

  • Kim, Heung-Dae;Chi, Yong-Chul
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.45-51
    • /
    • 1985
  • It is well known that intracranial pressure (ICP) and mean arterial pressure (MAP) are increased by laryngoscopy and endotracheal intubation during induction of general anesthesia, and It may be very dangerous in neurosurgical patients who had increased ICP. Therefore, this study was performed to know the range of ICP increase during induction of the conventional general anesthesia with intubation following thiopental and succinylcholine injections. Intracranial pressure and MAP were measured in 13patients who underwent cramotomy. All the patients were monitored cerebral epidural ICP and intra-arterial pressure pre-operatively. The results were as follow: 1. Intracranial pressure was increased of $7.1{\pm}7.23mmHg$. 2. Arterial pressure was increased of $43.5{\pm}25.46mmHg$. 3. Cerebral perfusion pressure was increased of $33.3{\pm}27.53mmHg$. It is stressed that certain procedures are necessary to prevent from further increase of ICP due to induction of general anesthesia in patients with increased ICP.

  • PDF

Effect of Head Elevation and Position on Intracranial Pressure(ICP) in the Neurosurgical Patient with a Cerebral Aneurysm (뇌동맥류 수술환자에게 적용한 두부체위가 두개강내압에 미치는 영향)

  • 박혜자;최경옥;이병옥;정은주;유양숙
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.3
    • /
    • pp.503-509
    • /
    • 1997
  • This study was undertaken to identify optimal head elevation and position in the care of the neurosurgical patient with a cerebral aneurysm. The effects of 0°. 15° and 30° head elevation and three positions (supine, side tying position opposite to the operation site, and side tying position on the same side as the operation site) on ICP was studied in fourteen neurosurgical patients with cerebral aneurysms. The results are as follows : 1. The mean intracranial pressure was significantly lower when the patient's head was elevated at 30° as compared to 0° and 15°. 2. The mean intracranial pressure was significantly lower when the patient was positioned in the supine as compared to side tying position opposite to the operation site and side tying position on the same side as the operation site. The data indicate that head elevation to 30° and the supine position reduce ICP in neurosurgical patients with cerebral aneurysm.

  • PDF

Study of improving precision and accuracy by using an internal standard in post column isotope dilution method for HPLC-ICP/MS (후 컬럼 동위원소 희석법을 적용한 HPLC-ICP/MS에서의 정량분석에서 내부 표준물을 이용한 정확도와 정밀도의 개선연구)

  • Joo, Mingyu;Park, Myungsun;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.140-146
    • /
    • 2014
  • An internal standard was used in PCID (post column isotope dilution) to improve the accuracy and precision in quantification of various chemical species. The error occurring in the column was the largest in HPLC-ICP/MS (high performance liquid chromatography-inductively coupled plasma/mass spectrometry) when PCID and other traditional quantification methods were compared with each other. Internal standard was effective in correcting the loss of sample in the column to improve accuracy and precision. When applied to SeMet, using MeSecys or $Se^{4+}$ as an internal standard, relative errors were reduced from 31% and 13% to less than 1%, while standard deviations were reduced from 5.1% and 6.9% to 1.5% and 0.2%, respectively. Positive aspects of using an internal standard in PCID were compared with other quantitative techniques and discussed in detail.

A short study of uncertainty for post column isotope dilution method in HPLC-ICP/MS (HPLC-ICP/MS에서 후 컬럼 동위원소 희석법의 기초적인 불확도 연구)

  • Joo, Mingyu;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.269-276
    • /
    • 2014
  • A short study for the uncertainty of post column isotope dilution method has been performed for the analysis of Selenomethionine in HPLC-ICP/MS. Major error sources studied were concentration and the flow rate of Se isotope solution, atomic weights of Se in spike and sample, and isotope ratio measured for the spiked sample. Uncertainties were obtained for each factor and the contribution for the total concentration uncertainty was 54.4% and 0.61%, 0.0072% and 0.018%, and 45.0%, respectively. The biggest contribution factor was concentration of the spike solution and the second was the isotopic ratio measured for the spiked sample solution. The mass flow rate of spike and atomic weights did not show much contribution. The calculated total uncertainty was $1.46ng{\cdot}g^{-1}$ for the standard SeMet ($126.30ng{\cdot}g^{-1}$). The experimental result was $127.09{\pm}1.46ng{\cdot}g^{-1}$ and the relative uncertainty was 1.20%.

dual frequency ICP 에서의 frequency 조합과 capacitance 변화에 따른 $SiO_2$ 및 poly-Si 식각특성

  • Kim, Jin-Ho;Kim, Hui-Dae;Lee, Nae-Eung;Heo, Seung-Hoe;Jang, Gi-Myeong;Nam, Chang-Gil;Son, Jong-Won
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2007.04a
    • /
    • pp.132-133
    • /
    • 2007
  • 2개의 주파수가 인가된 유도결합 플라즈마(ICP)를 이용하여 주파수 조합(13.56 or 27.12/2MHz)과 안테나의 캐패시턴스 변화에 따른 $SiO_2$ 와 poly-Si 의 식각특성을 연구하였다. 본 실험의 결과로, 27.12 MHz에서 plasma density가 높다는 것과 13.56 MHz에서 center high profile이 쉽게 형성됨을 알 수 있었다. $SiO_2$ 식각에서는 non-uniformity와 etch rate모두 27.12 MHz가 13.56 MHz보다 높다는 것을 알 수 있었고, poly-Si 식각에서는 non-uniformity와 etch rate모두 비슷한 경향을 나타낸다는 것을 알 수 있었다.

  • PDF

Significance of Intracranial Pressure Monitoring in Early Surgery for Poor-Grade Aneurysm Patients (중증 뇌동맥류 환자의 조기 수술에 있어서 뇌압 측정의 중요성)

  • Kim, Sang Su;Kim, Jong Moon;Kang, Sung Don
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.425-429
    • /
    • 2001
  • Objective : Patients with poor grade aneurysm usually present with increased intracranial pressure(ICP), even those without an intracranial clot. Based on this fact, the present study investigated a significance of intracranial pressure monitoring in those patients. Patients and Methods : A total of 60 patients with Hunt and Hess Grade IV(50 patients) or V(10 patients) were treated for aneurysmal subarachnoid hemorrhage(SAH) during a 3-year-period, and intraparenchymal ICP was measured in the majority, immediately after arrival to the emergency room. Early surgery including intraoperative ventriculostomy was undertaken within 3 days after SAH. An ultraearly surgery was performed without preceding angiogram or ICP monitoring in patients with large sylvian hematomas, highly suggestive of middle cerebral artery aneurysm. Outcomes were assessed by the Glasgow Outcome Scale(GOS) at 6 months. Results : In overall, favorable outcome(GOS scores 1-2) was seen in 27(54.0%) of admission Grade IV and 1(10.0%) of admission Grade V patients. Of the 38 surgical patients with preoperative ICP monitorings, 25 patients (80.6%) exhibiting ICP values of less than 40mmHg showed favorable outcome, however, no patients with ICP values above 40mmHg recovered(Fisher's exact test, p=0.0001). Conclusion : It is concluded that a preoperative ICP above 40mmHg before ventriculostomy indicate significant vital brain destruction as intractable intracranial hypertension, and Grade IV patients at admission with an ICP below 40mmHg can be of benefit from early surgical intervention while Grade V patients still remains unfavorable.

  • PDF