• Title/Summary/Keyword: Illuminance and uniformity

Search Result 68, Processing Time 0.029 seconds

Hybrid Illumination System Design based on Illuminance Uniformity for Surface Inspection (표면 검사를 위한 조도 균제도 기반 하이브리드 조명계 설계)

  • Cho, Eun Deok;Kim, Gyung Bum
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.3
    • /
    • pp.60-65
    • /
    • 2019
  • In this paper, the hybrid illumination system for effectively detecting surface defects in steel plate with lowcontrast, non-uniformity and featureless is designed based on illuminance uniformity. First of all, characteristics of steel plate defects were considered and typical inspection illumination system is implemented. Optimum illumination parameters for uniformly illuminating an inspection area in the typical illumination system are selected based on the illuminance uniformity and illuminance distribution measurement. The illuminance uniformity and illuminance distribution are measured using an illuminometer based on the arduino. Through illuminance distribution analysis of the typical illumination, an hybrid illumination is designed by fusing bi-directional illumination and coaxial illumination. The hybrid illumination showed higher uniformity ratio and illuminance distribution than the typical illuminations. The hybrid illumination system showed the ability to uniformly illuminate the entire inspection region of steel plate surface.

Overall Illuminance Uniformity of IRED Lighting in Nighttime CCTV

  • Sa-Gong, Geon;Park, Yung-Jun;Park, Jung-Je;Lee, Suho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2017
  • This study looks at optimizinge light redistribution to improve the overall illuminance uniformity of commercial IRED modules. To obtain uniform illumination over a prescribed rectangular area, a freeform surface lens was evaluated using TracePro. The LED light overall illuminance uniformity regulated in KSC 7658 was verified using Relux software. Experimental test results showed 0.81 overall illuminance uniformity for rectangular light distribution of LED lights having a radiation angle of $80^{\circ}$. After fabricating prototype IRED lights based on these simulation results, illuminance performance was observed when used as actual IRED lighting with a nighttime CCTV system. Image observation photographs of the prototype $80^{\circ}$ rectangular IRED lights confirmed that object images can be seen clearly owing to high overall illuminance uniformity, and that dark regions of the CCTV screen were not shown.

Analysis of the Illuminance Distribution on the Blackboard in Classroom of the Elementary and Senior (Junior) High School (초.중.고교의 흑판조도분포 분석)

  • Kim, Tae-Hyoun;Sun, Sang-Kweon;Park, Tong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1764-1766
    • /
    • 1997
  • In this paper, the illuminance distribution of blackboards on classroom in elementary, junior, and senior high school was measured and analyzed. Generally, average illuminance and uniformity of illuminance was 519[lx] and 0.543 (elementary: 389[lx], 0.387; junior: 632[lx], 0.570; senior: 527[lx], 0.608) respectively. When all lighting fixtures in each classroom were turned on, average illuminance was higher about 65% than lights-out, and, in case that local lighting fixtures exist, was higher 27% than absence, but uniformity of illuminance turned bad on the contrary ($0.462{\rightarrow}0.676$). According to classification into direction of windows on classroom. facing north, both were bad. In case of classroom to slant to east or west, the difference of illuminance at the forenoon and afternoon was big, and uniformity of illuminance was also bad.

  • PDF

Reflector Design to Improve the Uniformity of an Irradiated Area Using a Xenon Flash Lamp (제논 플래시 램프 사용 시 조사 영역 균일도 개선을 위한 반사경 설계)

  • Kim, Seo-Young;Lee, Han-Yul;Jun, Won-Kyoun;Kang, Dong-Hwa;Jo, Ye-Ji;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.5
    • /
    • pp.197-203
    • /
    • 2019
  • In this paper, we studied a reflector design that can improve the illuminance uniformity when using a xenon flash lamp in the photonic sintering process. To achieve complete sintering of substrates in the irradiated area, the light efficiency and illuminance uniformity were set to target performance. Existing elliptical reflectors or parabolic reflectors make it easy to satisfy the target light efficiency, but have difficulty satisfying the illuminance uniformity. In this paper, a twin-concave feature has been added to the center of the parabolic reflector to satisfy the illuminance uniformity. It was confirmed that the illuminance uniformity of the parabolic reflector with a twin-concave feature was improved, compared to that of the traditional reflector.

Illuminance Distribution and Photosynthetic Photon Flux Density Characteristics of LED Lighting with Periodic Lattice Arrangements

  • Jeon, Hee-Jae;Ju, Kang-Sig;Joo, Jai-Hwang;Kim, Hyun-Gyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.1
    • /
    • pp.16-18
    • /
    • 2012
  • LED lighting systems that combine lighting capability, emotional and physiological characteristics are required for lighting source and multifunctional applications. In this work, Simulation studies using optical analysis software packages, Light Tools, are presented. This is done to estimate the uniformity ratio of illuminance and photosynthetic photon flux density (PPFD) of the periodic 2D lattice arrangements, such as square, diamond, two-way bias quadrangular, hexagonal, and Kagome lattices, under the same transmissivity, absorptance and reflectivity. It has been found out that the two-dimensional Kagome lattice arrangement exhibited high uniformity ratio of illuminance and PPFD compared to other lattices. Accordingly, these results can be used to guide a design and improve the lighting environment which in turn would maximize the uniform distributions of illuminance.

Image Sensor Module for Detecting Space Illuminance in Indoor Environment (실내 환경의 공간조도 검출을 위한 이미지센서모듈)

  • Moon, Seong-Jae;Lim, Yeong-Seog
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.7
    • /
    • pp.771-778
    • /
    • 2019
  • The traditional illuminance intensity detection method using a single sensor has a problem that uniformity of illuminance detection is deteriorated depending on the measurement position due to the narrow FOV characteristic. In order to overcome this problem, a method of detecting an average illuminance value through a plurality of illuminance sensors is used, but the complexity and detection error are increased. In this paper, we propose a illuminance intensity detection method based on a single image sensor with wide FOV. The proposed method can solve the problems such as system complexity and error increase of existing illuminance sensor. The test results show that the difference of average value is 12% using a illuminance sensor, 10.7% using five illuminance sensors, and 6.2% using an image sensor compared with the reference value using the color difference illuminometer. It is confirmed that the proposed method can easily and accurately detect the space illuminance with improved uniformity.

Study on Analysis of Characteristics of Illuminance and Luminance Distribution of LED Luminaires (LED 조명기구의 조도.휘도분포 특성 분석에 관한 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Byoung-Soo;Han, Won-Tak
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.1-7
    • /
    • 2008
  • This study is intended to compare physical properties of fluorescent luminaires with ones of LED luminaires so as to analyze fundamental characteristics of LED luminaires. For this, a comparative analysis of uniformity ratio of illuminance and luminance distribution of these two luminaires was made, and materials for applying LED luminaires to interior construction space were prepared. This study was carried out in four stages. First, a theoretical review on LED illumination light source was made compared with the existing luminaires. Second, a mock-up to control experimental variables to meet the objective of this study was manufactured. Third uniformity ratio of illuminance and luminance distribution of each luminaire were measured by using the mock-up. Fourth, a comparative analysis of uniformity ratio of illuminance and characteristics of luminance distribution of the existing fluorescent luminaires and LED ones was made. As a result of the study, the uniformity ratio of illuminance of LED luminaires, 0.559, was higher than one of the existing fluorescent luminaires, 0.522. Namely, it was shown that illuminance distribution of LED luminaires was uniform and global diffuse was good. As a result of measuring luminance distribution, it was found that luminance distribution of LED luminaires was more uniform than one of the existing fluorescent luminaires. The maximum luminance of fluorescent luminaires and LED luminaires over the wall was $180.6[cd/m^2]$ and $155.26[cd/m^2]$ respectively. Namely, the maximum luminance of fluorescent luminaires was higher than one of LED luminaires. The average luminance of fluorescent luminaires and LED luminaires was $44.32[cd/m^2]$ and $58.65[cd/m^2]$. Like this, the average luminance of LED luminaires was higher than one of fluorescent luminaires. Considering these results, it's thought that LED luminaires can give a person in the room a more comfortable working environment than fluorescent luminaires.

The Actual State and Evaluation of Artificial Lighting on Coffee Houses Using Study Place around University (학습공간으로 이용되는 대학주변 커피전문점의 조명 실태 및 평가)

  • Choe, Sol-ji;Choi, Yoon-Jung
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.53-62
    • /
    • 2011
  • This study aimed at suggesting improvement of lighting environment of the coffee house using study place. To this end, a series of field investigation was conducted in four possible target coffee houses around university. The field measurement included measurement of general illuminance and tabletop illuminance, observing illumination condition, and status of artificial lighting. Also, on-site questionnaire survey was administrated to 80 users of field measurement targets about using characteristics of coffee house and user's subjective response on light environment. The results are summarized as follows: (1) According to questionnaire survey, most of users checked 'learning (study and reading)' in 'purpose of coffee house using', and 'slightly dark' was checked most in each subjective response (brightness on general space and on tabletop at daytime/night); (2) as results of measurements on general illuminance and on tabletop illuminance during daytime, only one coffee house was suitable for standard; (3) as results of measurements on illuminance during night, all target coffee houses were not met the standard; (4) as results of uniformity ratios, almost uniformities of general illuminance were not met the standard except one case. The common problems of lighting environment of coffee house were analyzed as lack of daylight illumination e.g. having low amount of sunshine from skylight, un-uniformity of insolation by floor plan and absence of window blind, and un-uniformity of artificial luminous intensity e.g. lack of the number or brightness of artificial lighting, using the indirect lighting, using only local lighting, and non-uniform arrangement of artificial lighting.

The design and the analysis of a LED illumination lens using the overlapped model (중첩모델을 이용한 조명용 LED 렌즈설계 및 분석)

  • You, Ilhyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.157-164
    • /
    • 2017
  • In this research, the overlapped illumination model was used for designing a freeform LED lens with a uniform illuminance distribution on its illuminating plane, and their performances and tolerances were compared. And, the illuminations on a illumination plane was measures for change with average illuminance and illuminance uniformity. As a result of the tolerance analysis about z-axis direction change, thickness change in lens and tilt change of light emission and characteristic change in LED source, overlapped model and divergent illumination model are similar to the performance about Z-axis direction change of light emission in LED source. but the uniformity illumination value in this overlapped model is more remarkably value than it in divergent illumination model about thickness change in LED lens. Also, even though the lens based on a divergent illumination model showed good performance compare to the lens based on an overlapped illumination model, the latter was less the deviation to variation of LED beam radiation ability.

Illuminance Distribution Analysis by Lighting Tower Position of o Soccer Stadium (축구 경기장의 조명타워 위치에 따른 조도분포 해석)

  • 김길영;최홍규;최병숙
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Nowadays the soccer becomes one of the best spot lighting sports in the world Especially the 2002 Korea-Japan World Cup was deeply impressed on all the korean. One goal of illuminating engineering should be the design of lighting system that can provide consistently high task visibility regardless of where a task might be located within a working space. The television broadcasting on the soccer has been an important role in the media. The standard of FIFA(The Federation Internationale do Football Association) requires recommended illuminance levels for artificial lighting for a player, an audience, TV broadcasting, as well as everybody in the stadium. This paper has proposed an algerian to select the suboptimal lighting tower position for watching and TV broadcasting a soccer game within a pleasant environment and an optimum illuminance distribution. The position using the software Philip's Calculux was chosen based an the calculations of a horizontal illuminance, vertical illuminance, uniformity, glare, and so on by changing lighting tower positions.