• Title/Summary/Keyword: Illuminance ratio

Search Result 76, Processing Time 0.027 seconds

Assessment of Daylight Environment on Light Pipe System Under Different Solar Position (태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가)

  • Shin, Hwa-Young;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.78-86
    • /
    • 2008
  • The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

An Analysis of Illuminance Distribution in Fine Art Museum with Girdle Skylight Type (미술관에서의 상부 띠형 천창의 채광분포에 관한 연구)

  • Choi, Man-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.93-100
    • /
    • 2005
  • Character and illuminance distribution of daylighting is very important for the architectural plan in museum. Those data show bases for exhibition space design with daylighting and play a decisive role in visual perception of articles and space aesthetic. The goal of this paper was therefore to analyze the illuminance distribution in fine art museum with 3 typical girdle skylight types which are devided according to the art of protection from glare. This Experiment proved that they had a striking contrast with regard to the ratio of daylight illumination and illuminance distribution in spite of the same purpose of those development. The girdle skylight with a translucent glass showed the strongest value of the ratio of daylight illumination, but inequable illuminance distribution in space, excepting the area of the wall. However, the latticed reflector of light refracted daylight in the direction of wall and made illuminance distribution very equable in whole space. The ratio of daylight illumination at the girdle skylight which was located at the verge of the ceiling, was highest at the upper part of the wall and was reduced gradually from there, by way of the middle and under part of the wall, to the center of space.

Analyses on Photosensor Illuminance for Prediction of Fluctuating Illuminance by Daylight Dimming Control Systems (조광제어 시스템 적용시 실내조도의 변동예측을 위한 포토센서의 주광조도 분석)

  • Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.788-797
    • /
    • 2010
  • This study examines the influence of fluctuating daylight illuminance on daylight dimming control systems. Field measurements were performed for a full-scale mocked-up model under various daylight conditions in winter. Fluctuating ranges for a partially-shielded photosensor were great when the variation of sky ratio was great. When solar altitude was lower the illuminance and fluctuating range of illuminance were great due to the influence of direct components of daylight and the interrefelction between surfaces in rear area of space. It implies that daylight dimming system would not function effectively, unless the desktop illuminance by daylight is enough. Fluctuation ranges of photosensor illuminance were lower than 50 lx under clear sky conditions, but they were greater than 100 lx under partly-cloudy sky conditions. It means that the fluctuation range of electric light output of lighting fixture would greater under the partly-cloudy conditions and cause potential visual annoyance to occupants. Outdoor vertical illuminance reaching the windows would be an effective factor that can be used to predict the fluctuation of photosensor signals for effective controls of daylight dimming system.

A Correlation Analysis between DSC (Dye Sensitized Cell) and Daylighting-Focusing on Educational Space (염료감응형 태양전지(DSC)와 자연채광의 상관관계 분석-교육공간을 중심으로)

  • Lee, Eung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.35-47
    • /
    • 2020
  • Due to the large window area, the lighting environment of the educational space between the window and deep part of the room is not uniformly illuminated, and the phenomenon of glare is severe. For this reason, the daylight performance of DSC-BIPV windows was analyzed in order to improve the natural lighting in the educational sector. The method derives the correlation with natural lighting by measurement and simulation. Dynamic simulation confirmed that the average illuminance of the target space was higher at later than the early afternoon. The performance of natural lighting at 40% and 30% transmission of DSC has the effect of significantly reducing the amount of excess light in existing windows. Nevertheless, the actual average illuminance in all seasons corresponds to the standard illuminance of the educational facility, 300 Lux. In addition, the uniformity is also seen through the skylight illuminance ratio.

An Experimental Study to Determine Proper Lighting Conditions in Powder Rooms

  • Kim, Hyun-Ji;Lim, Jang-Hyeon;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.54-62
    • /
    • 2013
  • In this study, a mock powder room was installed with variable LED lighting environments in order to conduct the experiments. The experimental conditions include luminaire type, illuminance ratio, vertical illuminance and color temperatures. The evaluation methods used were the Semantic Differential Method and a subjective evaluation on activities through observation. The SD evaluation result factor analysis categorizes ideas into three factors: brightness, emotion, and glare. The vertical bracket or the combined luminaire (luminous panel+ Vertical bracket) has better brightness than luminous panel. A vertical illuminance of 500lx is not significantly difference as compared to 600lx, allowing 500lx to be considered standard. The emotional atmosphere is evaluated as being better at lower color temperature. The luminous panel is the best for reducing glare while the vertical bracket is the worst. The best conditions differ according to the illuminance ratio of the luminous panel and vertical bracket. In the subjective evaluation (satisfaction with lighting environment, suitability to activity) the combined luminaire and 4000K received the best evaluation.

Hybrid Illumination System Design based on Illuminance Uniformity for Surface Inspection (표면 검사를 위한 조도 균제도 기반 하이브리드 조명계 설계)

  • Cho, Eun Deok;Kim, Gyung Bum
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.3
    • /
    • pp.60-65
    • /
    • 2019
  • In this paper, the hybrid illumination system for effectively detecting surface defects in steel plate with lowcontrast, non-uniformity and featureless is designed based on illuminance uniformity. First of all, characteristics of steel plate defects were considered and typical inspection illumination system is implemented. Optimum illumination parameters for uniformly illuminating an inspection area in the typical illumination system are selected based on the illuminance uniformity and illuminance distribution measurement. The illuminance uniformity and illuminance distribution are measured using an illuminometer based on the arduino. Through illuminance distribution analysis of the typical illumination, an hybrid illumination is designed by fusing bi-directional illumination and coaxial illumination. The hybrid illumination showed higher uniformity ratio and illuminance distribution than the typical illuminations. The hybrid illumination system showed the ability to uniformly illuminate the entire inspection region of steel plate surface.

Analyses on Daylight Variations for Optimum Controls of Daylight Dimming Systems in a Small Office (소규모 사무실에 적용된 조광제어 시스템의 최적제어를 위한 주광변화 분석)

  • Yoon, Youn-Ju;Baik, Yong-Kyu;Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.433-442
    • /
    • 2012
  • The influence of outdoor sky conditions on photosensor signals were examined to determine an appropriate index that is effectively used for optimum illuminance fluctuation when a daylight dimming system is used for a small office. Field measurements were conducted under various sky conditions. Results indicate that the outdoor global and vertical illuminance fluctuated within narrow ranges under clear and overcast sky conditions. The fluctuation of sky ratio under partly-cloudy sky caused wide ranges of illumnance fluctuation. A partially-shielded photosensor at backwall produced 56% of light output from fixtures controlled by a photosensor at ceiling. This implies that the photosensor at backwall does not always guarantee target illuminance due to the less output. The fluctuation of light output from fixtures were insignificant under clear and overcast sky. The fluctuation range of photosensor illuminance under partly-cloudy sky caused wide fluctuation ranges of light output. Regression result implies that the outdoor vertical illuminance was recommended for an effective index that is used for control of light output.

Illuminance Distribution and Photosynthetic Photon Flux Density Characteristics of LED Lighting with Periodic Lattice Arrangements

  • Jeon, Hee-Jae;Ju, Kang-Sig;Joo, Jai-Hwang;Kim, Hyun-Gyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.1
    • /
    • pp.16-18
    • /
    • 2012
  • LED lighting systems that combine lighting capability, emotional and physiological characteristics are required for lighting source and multifunctional applications. In this work, Simulation studies using optical analysis software packages, Light Tools, are presented. This is done to estimate the uniformity ratio of illuminance and photosynthetic photon flux density (PPFD) of the periodic 2D lattice arrangements, such as square, diamond, two-way bias quadrangular, hexagonal, and Kagome lattices, under the same transmissivity, absorptance and reflectivity. It has been found out that the two-dimensional Kagome lattice arrangement exhibited high uniformity ratio of illuminance and PPFD compared to other lattices. Accordingly, these results can be used to guide a design and improve the lighting environment which in turn would maximize the uniform distributions of illuminance.

Correlation between the Illuminance and the Flowering and Leaf Growth of Trees at Night - In Case of Downtown from Jamsil Station to Olympic Park, Seoul - (도심 내 야간의 조도와 봄철 수목 개화 및 잎 생장 간 상관관계 - 서울 잠실역에서 올림픽공원 구간을 대상으로 -)

  • Han, Bong-Ho;Kim, Jong-Yup;Kwak, Jeong-In;Choi, Tae-Young
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.3
    • /
    • pp.441-453
    • /
    • 2015
  • In this paper, according to the illuminance at night with artificial lighting in downtown Seoul, trees flowering and leaf growth rate was performed as a case study to examine whether there is a difference. The illuminance was measured at 78 points on a total of 26 points, the range of illuminance were divided into three groups considering land use, Group A (plots 1-7) were 4.90 ~ 112.50 lx, Group B (plots 8 to 18) were 0.45 ~ 42.40 lx, group C (plots 19 to 26) were 0.28 ~ 22.10 lx. According to the One-way ANOVA on illuminance difference, the survey groups were classified into three groups. To survey the ratio of the flowering Prunus yedoensis and Rhododendron spp. and to survey the ratio of leaf growth Zelkova serrata, Ginkgo biloba, and Acer palmatum each 30 individuals were investigated. Rhododendron spp. to study the ratio of the flowering and Acer palmatum to study the ratio of leaf growth were determined to be useful as indicator woody species according to the correlation. The higher illuminance of night lighting is, the faster flowering and leaf growth of trees will be by correlation between the mean illuminance of each group and the flowering and leaf growth of trees. In the future, should be made a more detailed study of how much affect to the trees with some impact on the level of light pollution at night lighting.

Preliminary Field Test on Daylighting Performance of Perpendicular Light Pipe System (수직형 라이트파이프의 채광성능에 관한 예비평가)

  • Shin, Hae Mi;Park, Hoon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.53-60
    • /
    • 2008
  • The daylighting affects on the human biological cycles and physiological alterations. Daylighting is also an important element in visual comfort and it sometimes influences the quality of vision. Therefore the absence of natural light during the day brings contradictory result. To solve the problems of natural light lack and provide sufficient daylight in interior spaces, it might be necessary to apply some daylighting systems. One of these systems, light pipe system, which is simple, cheep and easily constructed, is very useful to apply for small buildings. The light pipe is simple means of directing daylighting (diffuse and direct lighting)into interior space. In order to application of light pipe system in Korea, it is necessary to optical data of light pipe system. This study aims to evaluate preliminary experiment of the daylighting environment of light pipe system. Light pipe system, that aspect ratio is 1:2(diameter and length), was installed in a windowless mock-up with $27m^2$. The mock-up model was constructed as a prototype of Korean office surface. Illuminance was measured with a Topcon IM-5 Luxmeter to evaluate the distribution of the illuminance on a floor. The indoor and outdoor illuminance and the internal/external illuminance ratio are compared to discuss with in the graphs. Luminance was measured with Radiant imaging Promertric 1400 that is digital photometer to evaluate the distribution of luminance on interior surface. The contrast of luminance is discussed with table and graphs.