• Title/Summary/Keyword: Impedance

Search Result 6,412, Processing Time 0.034 seconds

PZT Impedance-based Damage Detection for Civil Infrastructures (토목 구조물의 PZT Impedance 기반 손상추정기법)

  • S. H. Park;Y. Roh;C. B. Yun;J. H. Yi
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.373-380
    • /
    • 2004
  • This paper presents the feasibility of an impedance-based damage detection technique using piezoelectric (PZT) transducers for civil infrastructures such as steel bridges. The impedance-based damage detection method is based on monitoring the changes in the electrical impedance. Those changes in the electrical impedance are due to the electro-mechanical coupling property of the piezoelectric material and structure. An effective integrated structural health monitoring system must include a statistical process of damage detection that is automated and real time assessment of damage in the structure. Once measured, damage sensitive features from this impedance change can be statistically quantified for various damage cases. The results of the experimental study on three kinds of structural members show that cracks or loosened bolts/nuts near the PZT sensors may be effectively detected by monitoring the shifts of the resonant frequencies. The root mean square (RMS) deviations of impedance functions between before and after damages were also considered as a damage indicator. The subsequent statistical methods using the impedance signature of the PZT sensors were investigated.

  • PDF

Design of an Inductively Coupled Plasma Source with Consideration of Electrical Properties and its Practical Issues (전기적 특성을 고려한 ICP Source 설계)

  • Lee, S.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.176-185
    • /
    • 2009
  • The realization and the performance of ICP source are strongly affected by its electrical impedance and the electric/magnetic field distribution. The ICP source impedance is determined by the antenna impedance and the plasma one. It is preferred to keep the imaginary impedance between -100 ohm to 100 ohm, since it should be avoided the high voltage formation on the antenna and abrupt impedance variation during the thin film process. The plasma uniformity is affected by the electric and magnetic field which is formed by the antenna current and voltage. The influence of azimuthal symmetry are shown by the electromagnetic simulation and the measurement result of plasma density. The radial uniformity can be controlled by locating the concentric antennas which have different diameters. The power distribution ratio and its control method are presented in the case of parallel antenna connections.

Estimation of human impedance and its application to collaboration work with robot (인간의 임피던스 추정 및 로봇과의 협력 작업으로의 적용)

  • 홍석규;김창호;서일홍
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1812-1815
    • /
    • 1997
  • This paper treats the estimation of human impedance and their application to collaboration work robot. Initially, we performa an experiment at whcich teh human becomes a slave and the robot behaves like a master having F/T sensor on its end. the human impedance expressed interms of mass, damping, and stiffness properties are estimated based on the force data measured by F/T sensor and the positiion data of the robot. To show the effectiveness of the estimated human impedance, we perform the second experiment at which the roles of the human and the robot are reversed. It is shown that the robot using the estimated human impedance follows the trajectory commanded by human very smoothly.

  • PDF

Intepretation of Faradaic Impedance for Corrosion Monitoring

  • Itagaki, M.;Taya, A.;Imamura, M.;Saruwatari, R.;Watanabe, K.
    • Corrosion Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.1-5
    • /
    • 2004
  • A polarization resistance is generally used to estimate the corrosion rate in the corrosion monitoring by an electrochemical impedance method. When the Faradaic impedance has a time constant due to the reaction intermediate, the electrochemical impedance describes more than one loop on the complex plane. For example, the electrochemical impedance of iron in acidic solution shows capacitive and inductive loops on the complex plane. In this case, the charge transfer resistance and the polarization resistance are determined at middle and low frequency ranges, respectively. Which should be selected for corrosion resistance in corrosion monitoring, the charge transfer resistance or the polarization resistance'? In the present paper, the above-mentioned question is examined theoretically and experimentally.

Leg Motion Monitoring using Bio-impedance Signal (생체 임피던스 신호를 이용한 하지동작 모니터링)

  • 송철규;변용훈;윤대영;김거식;임정모;전희천;권승범;이정훈;이명권
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2891-2894
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh and foot., and two potential electrodes are applied to the lateral aspect. medial aspect, and posterior position of lower leg. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least Interference, and maximum magnitude of impedance change. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level.

  • PDF

Local dynamic characteristics of PZT impedance interface on tendon anchorage under prestress force variation

  • Huynh, Thanh-Canh;Lee, Kwang-Suk;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • v.15 no.2
    • /
    • pp.375-393
    • /
    • 2015
  • In this study, local dynamic characteristics of mountable PZT interfaces are numerically analyzed to verify their feasibility on impedance monitoring of the prestress-loss in tendon anchorage subsystems. Firstly, a prestressed tendon-anchorage system with mountable PZT interfaces is described. Two types of mountable interfaces which are different in geometric and boundary conditions are designed for impedance monitoring in the tendon-anchorage subsystems. Secondly, laboratory experiments are performed to evaluate the impedance monitoring via the two mountable PZT interfaces placed on the tendon-anchorage under the variation of prestress forces. Impedance features such as frequency-shifts and root-mean-square-deviations are quantified for the two PZT interfaces. Finally, local dynamic characteristics of the two PZT interfaces are numerically analyzed to verify their performances on impedance monitoring at the tendon-anchorage system. For the two PZT interfaces, the relationships between structural parameters and local vibration responses are examined by modal sensitivity analyses.

Electro Mechanical Impedance Based Damage Detection in Beams with Temperature Effect (온도 영향을 받는 보 구조물의 EMI 기반 손상 검색)

  • Lee, Byung-Jun;Kim, Jeong-Tae;Ryu, Yeon-Sun;Na, Won-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.184-187
    • /
    • 2005
  • Physical changes in a structural system may cause changes in mechanical impedance of the system. Due to the electro-mechanical coupling effect in piezoelectric materials, this change can be monitoring by the electrical impedance of the piezoelectric sensor. In this paper, the variability of electro-mechanical impedance caused by temperature effect is assessed to adjust impedance data used for EMI based damage detection in beams. First experiments on beams are described. Next, experiments were performed under the temperature varying condition, in the range of $3^{\circ}C\;to\;23^{\circ}C$. Finally, the relationship between temperatures and impedance signatures is analyzed empirically temperature-frequency patten for the test structure.

  • PDF

Wireless Impedance-Based SUM for Bolted Connections via Multiple PZT-Interfaces

  • Nguyen, Khac-Duy;Kim, Jeong-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.3
    • /
    • pp.246-259
    • /
    • 2011
  • This study presents a structural health monitoring (SHM) method for bolted connections by using multi-channel wireless impedance sensor nodes and multiple PZT-interfaces. To achieve the objective, the following approaches are implemented. Firstly, a PZT-interface is designed to monitor bolt loosening in bolted connection based on variation of electro-mechanical(EM) impedance signatures. Secondly, a wireless impedance sensor node is designed for autonomous, cost-efficient and multi-channel monitoring. For the sensor platform, Imote2 is selected on the basis of its high operating speed, low power requirement and large storage memory. Finally, the performance of the wireless sensor node and the PZT-interfaces is experimentally evaluated for a bolt-connection model Damage monitoring method using root mean square deviation(RMSD) index of EM impedance signatures is utilized to estimate the strength of the bolted joint.

Modification of the experimental method for measuring acoustic impedance of perforated elements with grazing flow (스치는 유동이 존재하는 원형 천공의 음향 임피던스 측정 방법 개선)

  • Lee Seong-Hyun;Ih Jeong-Guon;Peat Keith
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.297-300
    • /
    • 2004
  • Perforated elements are extensively used in mufflers for the intake and exhaust systems of various fluid machines. Perforated elements are usually exposed to grazing flow or cross flow. For analyzing performances of mufflers, the impedance of perforated elements with mean flow is very important. The impedance of perforates under both conditions are measured with different experimental setups. Even if there is no flow, the preceding experimental method for grazing flow shows different values with both theoretical ones and measured under cross flow setup. Using high-order analysis considering phase differences, the experimental method for grazing flow can be modified. The acoustical impedance of perforated impedance contains interaction effects between orifices. After correcting these effects, the measured impedance with grazing flow setup show similar results with both theoretical impedance and measured ones under cross flow setup.

  • PDF

Modifications of Numerical Impedance Boundary Conditions Considering Incident Acoustic Pressure (음향 입사파를 고려한 수치적 임피던스 경계조건의 보정)

  • Kim, Min-Woo;Park, Yong-Hwan;Kim, Sung-Tae;Lee, Soo-Gab
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.344-348
    • /
    • 2007
  • The acoustic liner has been used for the suppression of noise. The impedance characteristics of the acoustic liner are increased by the incident pressure. For the estimation of the acoustic liner on the incident acoustic pressure effect, the modified impedance model is suggested on the basis of the GE impedance prediction model. The modified impedance model is originated from the 3 parameter impedance model, and extended to the incident pressure parameter. The modified model is applied on the simple duct analysis with variant source pressure. Through the computation, it is observed that the fore directivity patterns of the duct are varied by the incident SPL level.

  • PDF