• 제목/요약/키워드: Impedance

검색결과 6,415건 처리시간 0.038초

토목 구조물의 PZT Impedance 기반 손상추정기법 (PZT Impedance-based Damage Detection for Civil Infrastructures)

  • S. H. Park;Y. Roh;C. B. Yun;J. H. Yi
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 봄 학술발표회 논문집
    • /
    • pp.373-380
    • /
    • 2004
  • This paper presents the feasibility of an impedance-based damage detection technique using piezoelectric (PZT) transducers for civil infrastructures such as steel bridges. The impedance-based damage detection method is based on monitoring the changes in the electrical impedance. Those changes in the electrical impedance are due to the electro-mechanical coupling property of the piezoelectric material and structure. An effective integrated structural health monitoring system must include a statistical process of damage detection that is automated and real time assessment of damage in the structure. Once measured, damage sensitive features from this impedance change can be statistically quantified for various damage cases. The results of the experimental study on three kinds of structural members show that cracks or loosened bolts/nuts near the PZT sensors may be effectively detected by monitoring the shifts of the resonant frequencies. The root mean square (RMS) deviations of impedance functions between before and after damages were also considered as a damage indicator. The subsequent statistical methods using the impedance signature of the PZT sensors were investigated.

  • PDF

전기적 특성을 고려한 ICP Source 설계 (Design of an Inductively Coupled Plasma Source with Consideration of Electrical Properties and its Practical Issues)

  • 이상원
    • 한국진공학회지
    • /
    • 제18권3호
    • /
    • pp.176-185
    • /
    • 2009
  • ICP source의 성능과 구현 가능성은 impedance와 전기장, 자기장의 공간 분포에 큰 영향을 받는다. ICP source의 impedance는 ICP 안테나와 플라즈마의 impedance에 의해 결정된다. 안테나 설계에 있어서 안테나에 형성되는 고전압을 방지하고 공정 중 급격한 impedance 변화를 방지하기 위해서는 ICP source의 허수 impedance가 $-100\;ohm{\sim}+100\;ohm$의 영역에 존재하는 것이 유리하다. 플라즈마 균일도는 안테나에 흐르는 전류와 전압에 의해 형성되는 전기장 세기와 자기장 세기에 영향을 받는다. 원형 안테나와 대칭성이 개선된 안테나에 대해 전자기 simulation과 플라즈마 밀도의 공간분포를 측정하였으며 안테나 형태에 따른 전자기장과 플라즈마 밀도 분포의 개선을 확인하였다. 반경 방향 균일도를 조절하기 위해서는 일반적으로 지름이 다른 복수개의 안테나를 동심원 상에 배치하는 방법을 사용한다. 각 안테나들을 병렬로 연결한 경우 각각의 안테나의 임피던스에 따른 전류 분배 비율이 상이하며, 분배 비율을 조절하기 위해 코일 또는 capacitor를 연결할 경우 나타나는 현상을 계산하였다.

인간의 임피던스 추정 및 로봇과의 협력 작업으로의 적용 (Estimation of human impedance and its application to collaboration work with robot)

  • 홍석규;김창호;서일홍
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1812-1815
    • /
    • 1997
  • This paper treats the estimation of human impedance and their application to collaboration work robot. Initially, we performa an experiment at whcich teh human becomes a slave and the robot behaves like a master having F/T sensor on its end. the human impedance expressed interms of mass, damping, and stiffness properties are estimated based on the force data measured by F/T sensor and the positiion data of the robot. To show the effectiveness of the estimated human impedance, we perform the second experiment at which the roles of the human and the robot are reversed. It is shown that the robot using the estimated human impedance follows the trajectory commanded by human very smoothly.

  • PDF

Intepretation of Faradaic Impedance for Corrosion Monitoring

  • Itagaki, M.;Taya, A.;Imamura, M.;Saruwatari, R.;Watanabe, K.
    • Corrosion Science and Technology
    • /
    • 제3권1호
    • /
    • pp.1-5
    • /
    • 2004
  • A polarization resistance is generally used to estimate the corrosion rate in the corrosion monitoring by an electrochemical impedance method. When the Faradaic impedance has a time constant due to the reaction intermediate, the electrochemical impedance describes more than one loop on the complex plane. For example, the electrochemical impedance of iron in acidic solution shows capacitive and inductive loops on the complex plane. In this case, the charge transfer resistance and the polarization resistance are determined at middle and low frequency ranges, respectively. Which should be selected for corrosion resistance in corrosion monitoring, the charge transfer resistance or the polarization resistance'? In the present paper, the above-mentioned question is examined theoretically and experimentally.

생체 임피던스 신호를 이용한 하지동작 모니터링 (Leg Motion Monitoring using Bio-impedance Signal)

  • 송철규;변용훈;윤대영;김거식;임정모;전희천;권승범;이정훈;이명권
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2891-2894
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh and foot., and two potential electrodes are applied to the lateral aspect. medial aspect, and posterior position of lower leg. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least Interference, and maximum magnitude of impedance change. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level.

  • PDF

Local dynamic characteristics of PZT impedance interface on tendon anchorage under prestress force variation

  • Huynh, Thanh-Canh;Lee, Kwang-Suk;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • 제15권2호
    • /
    • pp.375-393
    • /
    • 2015
  • In this study, local dynamic characteristics of mountable PZT interfaces are numerically analyzed to verify their feasibility on impedance monitoring of the prestress-loss in tendon anchorage subsystems. Firstly, a prestressed tendon-anchorage system with mountable PZT interfaces is described. Two types of mountable interfaces which are different in geometric and boundary conditions are designed for impedance monitoring in the tendon-anchorage subsystems. Secondly, laboratory experiments are performed to evaluate the impedance monitoring via the two mountable PZT interfaces placed on the tendon-anchorage under the variation of prestress forces. Impedance features such as frequency-shifts and root-mean-square-deviations are quantified for the two PZT interfaces. Finally, local dynamic characteristics of the two PZT interfaces are numerically analyzed to verify their performances on impedance monitoring at the tendon-anchorage system. For the two PZT interfaces, the relationships between structural parameters and local vibration responses are examined by modal sensitivity analyses.

온도 영향을 받는 보 구조물의 EMI 기반 손상 검색 (Electro Mechanical Impedance Based Damage Detection in Beams with Temperature Effect)

  • 이병준;김정태;류연선;나원배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.184-187
    • /
    • 2005
  • Physical changes in a structural system may cause changes in mechanical impedance of the system. Due to the electro-mechanical coupling effect in piezoelectric materials, this change can be monitoring by the electrical impedance of the piezoelectric sensor. In this paper, the variability of electro-mechanical impedance caused by temperature effect is assessed to adjust impedance data used for EMI based damage detection in beams. First experiments on beams are described. Next, experiments were performed under the temperature varying condition, in the range of $3^{\circ}C\;to\;23^{\circ}C$. Finally, the relationship between temperatures and impedance signatures is analyzed empirically temperature-frequency patten for the test structure.

  • PDF

Wireless Impedance-Based SUM for Bolted Connections via Multiple PZT-Interfaces

  • Nguyen, Khac-Duy;Kim, Jeong-Tae
    • 비파괴검사학회지
    • /
    • 제31권3호
    • /
    • pp.246-259
    • /
    • 2011
  • This study presents a structural health monitoring (SHM) method for bolted connections by using multi-channel wireless impedance sensor nodes and multiple PZT-interfaces. To achieve the objective, the following approaches are implemented. Firstly, a PZT-interface is designed to monitor bolt loosening in bolted connection based on variation of electro-mechanical(EM) impedance signatures. Secondly, a wireless impedance sensor node is designed for autonomous, cost-efficient and multi-channel monitoring. For the sensor platform, Imote2 is selected on the basis of its high operating speed, low power requirement and large storage memory. Finally, the performance of the wireless sensor node and the PZT-interfaces is experimentally evaluated for a bolt-connection model Damage monitoring method using root mean square deviation(RMSD) index of EM impedance signatures is utilized to estimate the strength of the bolted joint.

스치는 유동이 존재하는 원형 천공의 음향 임피던스 측정 방법 개선 (Modification of the experimental method for measuring acoustic impedance of perforated elements with grazing flow)

  • 이성현;이정권
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 춘계학술발표대회 논문집 제23권 1호
    • /
    • pp.297-300
    • /
    • 2004
  • Perforated elements are extensively used in mufflers for the intake and exhaust systems of various fluid machines. Perforated elements are usually exposed to grazing flow or cross flow. For analyzing performances of mufflers, the impedance of perforated elements with mean flow is very important. The impedance of perforates under both conditions are measured with different experimental setups. Even if there is no flow, the preceding experimental method for grazing flow shows different values with both theoretical ones and measured under cross flow setup. Using high-order analysis considering phase differences, the experimental method for grazing flow can be modified. The acoustical impedance of perforated impedance contains interaction effects between orifices. After correcting these effects, the measured impedance with grazing flow setup show similar results with both theoretical impedance and measured ones under cross flow setup.

  • PDF

음향 입사파를 고려한 수치적 임피던스 경계조건의 보정 (Modifications of Numerical Impedance Boundary Conditions Considering Incident Acoustic Pressure)

  • 김민우;박용환;김성태;이수갑
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.344-348
    • /
    • 2007
  • The acoustic liner has been used for the suppression of noise. The impedance characteristics of the acoustic liner are increased by the incident pressure. For the estimation of the acoustic liner on the incident acoustic pressure effect, the modified impedance model is suggested on the basis of the GE impedance prediction model. The modified impedance model is originated from the 3 parameter impedance model, and extended to the incident pressure parameter. The modified model is applied on the simple duct analysis with variant source pressure. Through the computation, it is observed that the fore directivity patterns of the duct are varied by the incident SPL level.

  • PDF