• Title/Summary/Keyword: Indirect measurements

Search Result 178, Processing Time 0.029 seconds

A Comparision of a Direct and Three Indirect Methods of Measuring Blood Pressure (직접혈압측정치와 3가지 간접혈압측정치의 비교)

  • Lee Myung-Hwa;Park Hyo-Kyung;Shon Soo-Kyung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.1
    • /
    • pp.95-106
    • /
    • 1998
  • The purpose of this study was to compare direct and three indirect blood pressure measurements in adults and to compare among three indirect blood pressure measurements in adults. One direct(intraarterial) and three indirect(using a mecury sphygmomanometer, a aneroid type sphygmomanometer and an automatic auscultatory device) methods of blood pressure measurement were compared in adult patients who had an arterial line. The subjects for this study consisted of 29 patients in K medical center, B medical center, B hospital and M hospital in Pusan. The data was collected from October 1, 1992 to June 30, 1993. The collected data was analysed with the SPSS program, frequency, percentage, mean, S.D., t-test, ANOVA. The results of this study were as follows : 1) There was a significant difference in the systolic BP when using the direct and three indirect measurements(P<0.05). 2) There was no overall significant difference in the diastolic BP when using the direct and three indirect measurements. 3) There was no significant difference in the SBP and DBP among the three indirect measurements.

  • PDF

Accuracy of Indirect Anthropometry on Cast Model of The Nose: Comparison with Direct Anthropometry (코 석고모형에서 간접인체계측법의 정확성 : 직접인체계측법과의 비교)

  • Paik, Dae Hyang;Han, Ki Hwan;Won, Dong Chul;Choi, Tae Hyun;Kim, Jun Hyung;Son, Dae Gu
    • Archives of Plastic Surgery
    • /
    • v.35 no.1
    • /
    • pp.48-55
    • /
    • 2008
  • Purpose: We measured linear distances, angles and inclinations on the cast models of the noses, and compared these indirect measurements with the direct measurements obtained from the nose in order to validate the accuracy of the indirect anthropometry using the cast model. Methods: Subjects were 50 males and 50 females, medical students in twenties(mean 27.1 years). Cast models were made from the alginate impression material and the plaster. In direct anthropometry, 16 linear, 7 angular, and 2 inclination measurements between 11 landmarks on the nose were obtained using sliding caliper, spreading caliper, and fabric tape measure. At the same time, the same measurements were obtained from the cast models of the same people. Total 25 measurements were compared, and tested by the independent t-test of SPSS. Results: The standard values of Korean nose in twenties were obtained. 24 measurements except the columellar labial angle were not statistically different between the indirect anthropometry and the direct anthropometry. Conclusion: Indirect anthropometry on the cast model of the nose revealed no significant difference from the anthropometric measurement statistically, accounting for 24 in 25 measurements(96%). There are two possible reasons that caused the difference of columellar labial angle between direct and indirect anthropometry. First, the columellar labial angle could be decreased by protrusion of the lips which resulted from contracting mouth in which an drinking straw had been applied on the mouth corner for patients' respiration during making cast model. Second, it is generally known that the columellar labial angle could be measured larger when soft tissues were pressed by protractor in direct anthropometry. Using a drinking straw with greater diameter, and scheming respiration through the nostrils that patients don't feel discomfort, the more accurate data would be obtained from the indirect anthropometry using the cast models of the noses.

A Study on a Measurement Method for 2D Anthropometry using Digital Camera (디지털 카메라를 이용한 2D 인체계측법 연구)

  • 손희정;김효숙;최창석;손희순;김창우
    • The Research Journal of the Costume Culture
    • /
    • v.11 no.1
    • /
    • pp.11-19
    • /
    • 2003
  • This study suggests the new 2D anthropometric method using digital camera. It is used MK2001 program that can convert 2D measurements to 3D measurements. To improve that it is measured 100 college students with direct and indirect anthropometric method. The measurements were processed by the SPSS ver10 Statistical Package. The average, standard deviation, and t-test were calculated for each category. Most measurements by 2D measurements are higher than direct measurements but degree. The difference between direct and indirect measurements is less than 2cm. In the results of t-test, height measurements including other 16 measurements which is easy to measure have no meaningful difference within 1cm. The depth measurements are most high difference. The result of each measurement proves that MK2001 program (2D anthropometry method using digital camera) is available for measuring the human body.

  • PDF

A Study on the Body Measurements of Korean Female Adults Resident in China -With the Focus on their 20's, 40's, and 60's- (중국 조선족 성인 여성 신체 계측치 연구 -20대, 40대, 60대를 중심으로-)

  • Im Soon;Seok Hye-Jung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.9_10 s.146
    • /
    • pp.1241-1252
    • /
    • 2005
  • This study tried to compare and analyze the body measurements of female adults in China by various age groups. As for the study method, direct and anthropometric measurements were used on the 357 female subjects living in Yenbien and Harbin, China, consisting of 122 women in their 20's, 114 women in their 40's, and 121 women in their 60's. The results were as follows: 1. The comparison of major body measurements between Korean Chinese and Korean in land indicated that the former were shorter and plumper than the latter. Those groups in their 60's did not show any significant difference in height related measurements and revealed less differences in body measurements comparing to other age groups. 2 The comparison of Chinese anthropometric measurements among age groups of Korean Chinese indicated that, higher the age, shorter the height measurements, the leg length shorter, the upper-half body length longer, and the chest drooping due to the breast descent. 3. The comparison of indirect measurements among age groups of Koreans Chinese indicated that those in their 60's showed many items of big discrepancies in comparison with those in their 20's or 40's, with wide gap in discrepancies, thus resulting in large differences among individuals.

Disagreement between direct and indirect blood pressure measurements obtained from minipigs

  • Lee, Won-Jae;Park, Lisa Soyeon
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.3
    • /
    • pp.131-136
    • /
    • 2018
  • Blood pressure (BP) measurement plays a pivotal role in veterinary medicine for diagnosing cardiovascular disorders and monitoring anesthesia of animals. Although indirect BP measurement has been widely applied to monitor BP because of its convenience and non-invasiveness, it is still unclear whether indirect BP measurement is compatible with direct BP measurement in minipigs. In addition, the effect of animal posture during BP measurement is not well understood in minipigs despite its importance to cardiovascular performance. Therefore, both systolic and diastolic arterial BPs in minipigs were measured via femoral artery catheterization for direct BP measurement and using a compressive cuff as an indirect BP measurement under the dorsal or right lateral recumbent postures. Numerical values were processed by the Bland-Altman method to calculate the bias ${\pm}$ SD and the limits of agreement (LOA). In accordance with the American College of Veterinary Internal Medicine guidelines, the results between direct and indirect BP measurements were determined as apparent disagreements in both systolic and diastolic arterial BPs under all postures because of large bias ${\pm}$ SD and wide LOA. The results of the present will help prevent misinterpretation of the anesthetized patient's condition during monitoring of BP by indirect measurement.

A Study on The Elderly Women's Lower Body Types and Basic Skirt Pattern Adjustments (노년대성의 스커트 착의 적합성에 관한 연구)

  • 김금화;최혜선
    • Journal of the Korean Home Economics Association
    • /
    • v.38 no.2
    • /
    • pp.155-166
    • /
    • 2000
  • The purpose of this study was to provide the basic information about the elderly women's lower body type and anthropometric data by direct and indirect measurements, and to provide well fitting skirt patterns of each body types. Direct and indirect measurements were taken from 202 women, whose ages were between 60 and 79. Using statistical analysis, the lower body shapes of elderly women were classified into four following categories - \circled1 thin type, \circled2 typical type, \circled3 corpulence type and \circled4 corpulence but forward inclining type. Methods of modifying basic skirt patterns for each body types were suggested.

  • PDF

Establishment of Ultrasonic Measurement and Correlations of Direct-Indirect Method for Weathering Evaluation of Stone Cultural Heritage (석조문화재 풍화도 평가를 위한 초음파 측정의 설정과 직접-간접전달방법의 상관관계)

  • Lee, Chan-Hee;Jo, Young-Hoon;Chun, Yu-Gun
    • Journal of Conservation Science
    • /
    • v.25 no.3
    • /
    • pp.233-244
    • /
    • 2009
  • This study was focused on the transducer and suitable contact material for stone cultural heritage, and the correlation of direct-indirect method in rock types for scientific development and quantitative evaluation technique of the ultrasonic measurements. As a result, it was identified the transducer (UTREXTX(RX)54kHz) and contact material (rubber clay) of the type 3 were appropriate for the ultrasonic measurements of stone cultural heritage. The direct-indirect correction factors of type 3 were calculated 1.50 for granite, 1.38 for gabbro, 1.58 for quartz diorite, respectively. This result is the first study for improvement in reliability for the ultrasonic measurements, and it will contribute to establishment of the ultrasonic survey method for stone cultural heritage. Also, complementary studies considering the surface irregularity of rocks and various contact materials will carry out, and the database about correlation of direct-indirect in rock types will establish.

  • PDF

Application of the Indirect Effect on Regional Gravith Fielcs in the North Atlantic Ocean (北大西洋 重力場에 적용한 Indirect Effect)

  • 정우열;필립로
    • 한국해양학회지
    • /
    • v.22 no.1
    • /
    • pp.19-24
    • /
    • 1987
  • Gravity measurements at sea are considered to be made on the geoid. The free-air anomalies are then determined by subtracting the theoretical gravity values predicted on a reference ellipsoid from the observed values. The gravity effect due to the height difference between the geoid and reference ellipsoid and the mass between them is known as the 'indirect effect'. The result of applying the indirect effect to surface ship derived gravity anomalies in the North Atlantic Ocean demonstrates the importance of its inclusion for regional stuedies involving mantle processes.

  • PDF

Frequency Response of the electrode for Indirect-contact ECG (간접접촉 심전도 측정용 전극의 주파수 특성)

  • Lim, Yong-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.249-253
    • /
    • 2008
  • The indirect-contact ECG (IDC-ECG) was introduced by a prior study for daily non-intrusive measurements. To improve the signal quality and to extend the application area of IDC-ECG, close study of the frequency characteristics of the IDC-ECG is necessary. In this study, the frequency response of the active electrode for several sample clothes was measured under conditions of actual IDC-ECG measurement with human body. Higher gain in low frequency range than expected by prior study was observed. In addition to it, wide variation in gain according to the cloth type in the low frequency range was observed. Variation in gain caused by moisture variation in the clothes was also observed. This study shows that the parallel R-C connection is proper for electrode model and the resistive factor is influenced by moisture in the clothes. This study is the first that provides the frequency response of the electrode in the actual indirect-contact ECG measurement and it is expected that the results will be helpful to improve the indirect-contact ECG method.

Comparison of Ultrasonic Velocities between Direct and Indirect Methods on 30 mm × 30 mm Spruce Lumber

  • OH, Sei Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.562-568
    • /
    • 2020
  • This study investigates the relationship between ultrasonic velocity and density in the direct method, the effect of distance between transducers in the indirect method, and the difference between the direct and indirect methods with transducers placed at a distance of 200 mm in nondestructive ultrasonic testing of spruce lumber. The direct method using 54 kHz ultrasonic transducers was applied to two planes, namely, radial section (LR) and tangential section (LT) of samples. The indirect method measurements were taken using the same transducers. Two velocities were measured at the top and bottom of the LT plane and at the two sides of the LR plane; the two values for each plane were averaged. The relationship between density and ultrasound velocity in the direct method demonstrated a positive correlation between the two variables. The difference between the two planes, LT and LR, was not statistically significant. Moreover, the distance between the transducers in the indirect method affected ultrasound velocity, with the ultrasonic velocity increasing as the distance between the transducers became larger. A transducer distance of 200 mm yielded a close approximation of the direct method results with a ratio of 0.87. Finally, no statistical evidence of a difference between the two planes in the indirect method was found. If the direct method, which requires access to two surfaces, is impractical, the indirect method can be applied.