• Title/Summary/Keyword: Induced horizontal prism

Search Result 6, Processing Time 0.025 seconds

Induced Prism by the Categories of Spectacle Frames (안경테 종류에 따른 유발프리즘)

  • Park, Woo-Jung;Kim, Soo Woon;Hwang, Hae-Young;Yu, Dong-Sik;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.311-319
    • /
    • 2012
  • Purpose: One of the critical aspects on dispensing glasses is to match the center of pupils to the optical center of lenses as the mismatched glasses are able to induce uncomfortable effects called prism which has been known to induce phoria, a main cause for asthenopia in many cases. Therefore, we investigated the induced prism occurred by mismatching centers between the center of pupils and the optical center of lenses. Methods: In this study, total 103 subjects were examined whether the center of pupils and the optical center of lenses are matched in horizontal and vertical directions, and then, the data was categorized into 4 groups based on the structural components of glasses. Total amount of prism was compared to show the effect of the glasses frame on the prism induction, and the value of measured prism was compared with the German RAL-RG 915 regulations. Results: The results in respect to the horizontal component showed that the induced prism was not found in 10.7% of total subjects. 73.8% of total subjects were influenced by induced prism, the range of prism was in a tolerance level. However, the 15.5% of total subjects seemed to be influenced by prism which is out of the criterion of tolerance. In case of vertical component, 23.3% of total subjects showed no effects of prism while early adopting glasses, 54.4% of total subjects showed a little prism effect within the criterion of tolerance, and 22.3% of total subjects showed the prism effect out of the tolerance range. This data indicates that group A and B that are less likely adjustable by fitting induce more prism than group C and D in horizontal and vertical components. Conclusions: In higher refractive error condition, it was found that aligning the optical center of lenses with the center of pupils by pre-fitting of glasses frame minimized prism induction in horizontal and vertical components, which ameliorates ocular fatigue. Therefore, appropriate optometric dispensing through fitting by opticians and precise design about monocular PD and monocular Oh are necessary to improve visual perception.

Measurement of Horizontal and Vertical Prism Diopter According to Difference between the Optical Center and Pupil Center (안경 광학중심과 동공중심의 불일치에 의한 수평, 수직 유발프리즘의 측정)

  • Kim, Hyojin;Park, Jee-Hyun;Park, Seon-A;Baek, Ji-Seon;Lee, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: Measurement of the horizontal and vertical prism diopter was investigated which was occurred due to distance differences between the optical inter-centeral distance (OC) and the interpupillary distance (PD) of the prescribed glasses. Methods: We surveyed 96 subjects (192 eyes) at the average age of 21.56 years old. The PD was measured by using the PD measurement system (DONGYANG PD-85, Korea), and the OC of the glasses was measured by using the projective peak refractive power measurement system (TOPCON CL-200, Japan). The OH value was measured by using Penlight and the PD ruler. Results: The PD which had been measured by the PD system and the OC of the glasses revealed 78.1% of differences. 62.5% of the objects were base-in value prescribed glasses; 58.3% were out of permissible error. Only 8 subject showed concurrence between the prescribed glasses and the OH value, and 82.3% of the objects were induced vertical prism of over 1 (prism diopter). Conclusions: In order to improve the vision function of people who wear glasses, it is necessary to advance the accuracy of PD, OH measurement and making glasses as well.

Induced Prisms of Wearing Glasses Measured by Photographing (사진촬영으로 측정한 착용안경의 유발프리즘)

  • Shin, Hyung-Sup;Jang, Jun-Kyu
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.527-532
    • /
    • 2014
  • Purpose: The matching of the optical center and the pupil center was measured by photographs in wearing glasses. In this study, the influences of the induced prism by the mismatching are studied. Methods: 74 subjects (148 eyes) who were spectacles wearer were participated in this study. The mean age was $29.19{\pm}12.22$ years (range 19-55 years). The facial photographs of subjects were taken while wearing spectacles. The matching of the corneal reflected image and optical center of the spectacle lens in the horizontal deviations, and the vertical deviations were measured by the observation of the photo image. The prisms induced in accordance with various frame type were calculated from the mismatching deviations. Results: The binocular horizontal deviations were $1.55{\pm}1.70mm$ for the metal frame, $1.71{\pm}2.21mm$ for the clings type plastic frame, and $1.15{\pm}1.38mm$ for the plastic frame. In the horizontal direction induced prism, the ratio over the tolerance was 23%. The ratio were the 17.6% at the BI prism, and 5.4% at the BO prism. The binocular vertical deviation comparisons were $3.93{\pm}1.91mm$ for the metal frame, $5.79{\pm}1.93mm$ for the clings type plastic frame, and 1$6.01{\pm}2.94mm$ for the plastic frame. In the vertical direction induced prism, the ratio over the tolerance was 44.6%. Based on the refraction power, the ratio were 12.2% at -0.25${\leq}-3.00$, and 32.4% at -3.00${\leq}-12.00D$. Conclusions: The induced prisms in the horizontal direction were much in the BI prism. The binocular vertical deviations of the glasses.

A Study for the Horizontal Induced Phoria in Spectacles Wearers (안경 장용자의 수평 유발 사위에 관한 연구)

  • Sung, Duk Yong;Lee, Won Jin;Kang, Sung Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.2
    • /
    • pp.85-91
    • /
    • 1996
  • Among the 110 glasses wearers, the hyperopic glasses wearers were 18(16.36%) persons and myopic glasses wearers were 92(83.64%) persons. The distance for optical centers was coincided to the pupillary distance in 9(8.18%) persons and discrepant in 101(91.82%) persons. Ophthalmic dispensing Pupillary Distance resulted from testing by the trouble error range(Germany RAL-915), unadopt spectacles had been wearers 52(51.49%) persons. The 65(64.56%) persons and 36(35.64%) persons showed the induced esophoria and the induced exophria, respectively. The maximal induced esophoria was 3.69 prism diopters and maximal induced exophoria was 3.68 prism diopters.

  • PDF

Head Posture-Induced Phoria Deviation (머리 위치에 따른 사위도의 변화)

  • Ha, Eun-Mi;Son, Jeong-Sik;Moon, Byeong-Yeon;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.155-160
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate how phoria variations would vary with head positions, as well as to review the need to differentiate prism placement over either eye in a relation to the imbalance of the extraocular muscle. Methods: This study was carried out with 44 males (88 eyes) and 16 females (32 eyes) aged between 20 and 30. For all subjects, testings were performed using cover test, subjective refraction, phoria and vergence test. To analyze phoria variations comparatively for the head tilt test and the face turn test, phoria deviation were measured using the von Graefe. Results: For the phoria variation related with head tilt and face turn, a significant difference was observed in the group judged to be abnormal on the horizontal phoria of Morgan' norm (p<0.05); especially in patients who needed near prescription of Sheard's criterion, a higher variation was observed (p<0.05). The abnormal group was composed of patients who needed distance prescription of Sheard's criterion and ones who did not need the prescription, all of whom showed phoria variations, but the mean value was less than the near. Conclusions: With regard to the head tilt and face turn related phoria level, the patients who needed near horizontal prism prescription of Sheard's criterion showed a remarkably higher variation. Altogether, it is deemed to check whether extraocular muscles are ill-balanced in both eyes previously to determine the prism power on phoria level to the end that each of prism powers may be accurately determined.

Binocular Vision Corrective Spectacle Lenses Reduce Visual Fatigue in 3-D Television Viewing (양안시 교정안경의 3차원 텔레비전 시청 중 발생한 안정피로 감소)

  • Yoon, Jeong Ho;Kim, Jae-Do
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.363-369
    • /
    • 2014
  • Purpose: Three-dimensional (3D) displays are very useful in many fields, but induce physical discomforts in some people. This study is to assess symptom type and severity of asthenopia with their habitual distance corrective spectacle (HDCS) and their binocular vision corrective spectacle lenses (BVCSL) in people who feel physical discomforts. Methods: 35 adult subjects (ages $32.2{\pm}4.4$ yrs) were pre-screened out of 98 individuals to have the highest symptom/asthenopia scores following 65 minutes of 3D television viewing with HDCS. These 35 individuals were then retested symptom/asthenopia scores during they watched 3D television for 65 minutes at a distance of 2.7 m with wearing BVCSL of horizontal, vertical or base down yoked prisms. A 4-point symptom-rating scale questionnaire (0=no symptom and 3=severe) was used to assess 11 symptoms (e.g., blur, diplopia, etc.) related to visual fatigue/visual discomfort. Distance and near lateral phoria were measured using Howell phoria card and vertical phoria were measured using Maddox rod. Symptoms induced by watching 3D TV were compared between wearing HDCS and BVCSL. Results: Asthenopia in watching 3D TV with wearing BVCS was significantly lower than wearing HDCS at 5, 25, 45, and 65 minutes (all p < 0.001, paired t-tests). In only refractive error power correction power group, all asthenopia was not significantly different between HDCS and BVCSL (all $p{\geq}0.05$, paired t-tests). In prism correction groups for binocular imbalance, symptoms of asthenopia, however, was significantly lower for when wearing BVCSL than when wearing HDCS (all p < 0.05). Conclusions: Correction of phoria/vergence-based binocular vision imbalance can reduce asthenopia during 3D television viewing. An individual with binocular vision imbalance need corrected/compensated glasses with appropriate prisms prior to prolonged viewing of 3D television displays to reduce asthenopia/visual fatigue.