• Title/Summary/Keyword: Industrial Scientific Medical

Search Result 111, Processing Time 0.025 seconds

Analysis TVWS Propagation Environment for Indoor M2M Service (실내 M2M 서비스를 위한 TVWS 전파 환경 분석)

  • Yun, Deok-Won;Chang, Hyung-Min;Lee, Won-Cheol
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.8
    • /
    • pp.763-771
    • /
    • 2013
  • In this paper, the propagation characteristics for ISM(Industrial Scientific and Medical) and TVWS(TV White Space) in indoor building environment are analyzed in comparison with theoretical and experimental results, the excellent propagation characteristics of the TVWS is confirmed. To this end, signals which have center frequencies of 503 MHz and 2.4 GHz are generated in building propagation environment. Through that, received power strength is measured according to the location and measured path loss is analyzed. Theoretical path loss is calculated using Hata, Extended Hata, Extended Hata SRD, ITU-R P.1238 and reliability for channel model in indoor environment is analyzed.

Channel Selection Method of Wireless Sensor Network Nodes for avoiding Interference in 2.4Ghz ISM(Industrial, Scientific, Medical) Band (2.4Ghz ISM(Industrial Scientific Medical) 밴드에서 간섭을 회피하기 위한 무선 센서 노드의 채널 선택 방법)

  • Kim, Su Min;Kuem, Dong Hyun;Kim, Kyung Hoon;Oh, Il;Choi, Seung Won
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.4
    • /
    • pp.109-116
    • /
    • 2014
  • In recent, ISM (Industrial Scientific Medical) band that is 2.4GHz band authorized free of charge is being widely used for smart phone, notebook computer, printer and portable multimedia devices. Accordingly, studies have been continuously conducted on the possibility of coexistence among nodes using ISM band. In particular, the interference of IEEE 802.11b based Wi-Fi device using overlapping channel during communication among IEEE 802.15.4 based wireless sensor nodes suitable for low-power, low-speed communication using ISM band causes serious network performance deterioration of wireless sensor networks. This paper examined a method of identifying channel status to avoid interference among wireless communication devices using IEEE 802.11b (Wi-Fi) and other ISM bands during communication among IEEE 802.15.4 based wireless sensor network nodes in ISM band. To identify channels occupied by Wi-Fi traffic, various studies are being conducted that use the RSSI (Received Signal Strength Indicator) value of interference signal obtained through ED (Energy Detection) feature that is one of IEEE 802.15.4 transmitter characteristics. This paper examines an algorithm that identifies the possibility of using more accurate channel by mixing utilization of interference signal and RSSI mean value of interference signal by wireless sensor network nodes. In addition, it verifies such algorithm by using OPNET Network verification simulator.

Compatibility between ISM Equipment and WiBro Service at 2.3 GHz band (2.3 GHz 대역의 ISM 기기와 WiBro 서비스의 양립성 분석)

  • Shim, Yong-Sup;Lee, Il-Kyoo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.2
    • /
    • pp.101-105
    • /
    • 2011
  • This paper calculates protection distance to protect WiBro service from ISM(Industrial Scientific Medical) equipment which is used in the same frequency with WiBro. We analyze with a scenario that WiBro receiver is closed to ISM equipment which has interfering power of CISPR(International Special Committee on Radio Interference) 11 limit. As a result, the protection distance of 14 m was calculated by using MCL (Minimum Coupling Loss) for the worst case. And, the protection distance of 10 m was calculated to meet 5 % interference probability below by using MC(Monte Carlo) for statistic analysis in case of a interferer.

Study on Compatibility between ISM Equipment and WLAN (ISM 기기와 무선랜의 양립성에 관한 연구)

  • Shim, Yong-Sup;Lee, Il-Kyoo;Cho, Ju-Phil;Min, Kyoung-Il
    • Journal of Satellite, Information and Communications
    • /
    • v.6 no.1
    • /
    • pp.63-67
    • /
    • 2011
  • This paper analyzes the interference effect of ISM(Industrial Scientific Medical) equipment on WLAN in order to protect WLAN in interference environment which WLAN Station is close to ISM equipment. CISPR(International Special Committee on Radio Interference) radiation limit standard was used for interfering power of ISM equipment. Then, MCL(Minimum Coupling Loss) which is for the worst case and MC(Monte Carlo) which is based on statistic interference probability are used to get protection distance. As a result, the protection distance of 105 m was calculated by using MCL for the worst case. And, the protection distance of 17 m was calculated by using MC for statistic analysis.

Study on Radiation Limit of ISM Equipment for Protecting Radio Device (무선기기 보호를 위한 ISM 기기의 방사 한계치에 관한 연구)

  • Shim, Yong-Sup;Lee, Il-Kyoo;Hong, Seon-Eui
    • Journal of Satellite, Information and Communications
    • /
    • v.6 no.2
    • /
    • pp.10-14
    • /
    • 2011
  • This paper suggests the method to calculate radiation limit of ISM(Industrial Scientific Medical) equipment in order to protect radio device in the situation that ISM equipment and radio device are operated in near distance. The factor for correction and protection ratio which is need for protecting radio device were considered to calculate radiation limit of ISM equipment. Also, the scenario which is required to limit radiation power of ISM equipment was referred and the S/W for calculation of radiation limit was developed by using GUI(Graphical User Interface) on Matlab. The suggested method for calculation of radiation limit of ISM equipment will be used to protect radio device from ISM equipment.

Detection algorithm for DAA using Decision Directed method in MB-OFDM (MB-OFDM에서 충돌회피를 위한 결정궤환방식의 간섭신호 검출 기법)

  • Oh, Woo-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.315-321
    • /
    • 2011
  • Since the MB-OFDM(Multi-Band Orthogonal Frequency Division Multiplexing) is an ultra wideband communication system operated on ISM(Industrial, Scientific and Medical) band, DAA(Detect-And-Avoid) is required for co-existence with the other communication service. In this paper we propose the new detection algorithm based on decision-feedback, which shows faster convergence time and less complexity than previous works. The proposed algorithm detects interference above -20dB in AWGN(Additive White Gaussian Noise) and LOS(Line-Of-Sight) channel, and close to AWGN in non-LOS channel under appropriate channel clipping.

Performance Analysis of BLE System for Wireless IoT Network Design (IoT 무선 네트워크 설계를 위한 BLE 시스템의 성능 분석)

  • Jae-sung Roh
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.6
    • /
    • pp.481-486
    • /
    • 2022
  • The recent rapid growth of the IoT(Internet of Things) is leading to the spread of low-power wireless technology. A major challenge in designing IoT wireless networks is to achieve coexistence between different wireless technologies that share the 2.4 [GHz] ISM (Industrial Scientific Medical) frequency band. Therefore, there is a need for research on improving the reliability of wireless networks and coexisting operation between wireless networks. In particular, it is necessary to study an interference model and performance for mutual service coexistence in a BLE (Bluetooth Low Energy) wireless network environment, which is expected to be widely used as a connection medium between devices in various industrial fields. In this paper, the co-channel interference model with the IEEE 802.15.4 system is established focusing on the physical layer of the BLE system widely used in residential and industrial wireless applications, and the performance of the BLE wireless communication system is analyzed in the co-channel interference environment. As a result of the analysis, as the distance between the interference source and the BLE system increases in an environment where noise and co-channel interference exist, the amount of co-channel interference decreases and the error rate performance of the BLE system improves.

Risk-based Operational Planning and Scheduling Model for an Emergency Medical Center (응급의료센터를 위한 위험기반 운영계획 모델)

  • Lee, Mi Lim;Lee, Jinpyo;Park, Minjae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.2
    • /
    • pp.9-17
    • /
    • 2019
  • In order to deal with high uncertainty and variability in emergency medical centers, many researchers have developed various models for their operational planning and scheduling. However, most of the models just provide static plans without any risk measures as their results, and thus the users often lose the opportunity to analyze how much risk the patients have, whether the plan is still implementable or how the plan should be changed when an unexpected event happens. In this study, we construct a simulation model combined with a risk-based planning and scheduling module designed by Simio LLC. In addition to static schedules, it provides possibility of treatment delay for each patient as a risk measure, and updates the schedule to avoid the risk when it is needed. By using the simulation model, the users can experiment various scenarios in operations quickly, and also can make a decision not based on their past experience or intuition but based on scientific estimation of risks even in urgent situations. An example of such an operational decision making process is demonstrated for a real mid-size emergency medical center located in Seoul, Republic of Korea. The model is designed for temporal short-term planning especially, but it can be expanded for long-term planning also with some appropriate adjustments.

Expression of P-glycoprotein is Positively Correlated with p53 in Human Papilloma Virus Induced Squamous Intraepithelial Lesions of Uterine Cervix: Poor Prognosis Association

  • Singh, Madhulika;Singh, Uma;Mathur, Neeraj;Shukla, Yogeshwer
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6039-6045
    • /
    • 2012
  • This study was conducted to assess the predictive value of p-glycoprotein (p-gp) and p53 immunoexpression in human papillomavirus (HPV) infected cases of cervical dysplasia. Expression of both p-gp and p53 proteins was detected in cervical smears from 177 squamous intraepithelial lesions (SIL) cases along with 183 "atypical squamous cells of unknown significance" (ASCUS) and 150 normal cases. HPV 16 and 18 infection was detected by polymerase chain reaction using type-specific primers for HPV sub-types. There were no significant detectable p53 and p-gp expression in the normal cervix smears (p>0.05). In the ASCUS group 10 cases were positive for both p53 and p-gp immunoreactivity. In cervical dysplasia cases, p53 was positive in 86 (48.58%) while p-gp was positive in 93 (52.54%) and the two markers showed a highly significant correlation (r=0.92, p<0.001). Expression of p53 and p-gp was associated with grade of SIL (p<0.001). A positive correlation between the presence of HPV and expression of proteins p53 and p-gp in smears of patients with cervical lesions was also noted (p<0.001). Thus, p53 and p-gp immunostaining in cervical smears may act as an auxiliary biomarker for detection of HPV-associated cervical lesions. Additionally, a significant positive correlation between ascending grades of SIL and labeling indices of markers suggests that p53 and p-gp can be used as an adjunct to cytomorphological interpretation of conventional cervical Pap smears.

2.5 GHZ SECOND-AND FOURTH-ORDER INDUCTORLESS RF BANDPASS FILTERS

  • Thanachayanont, Apinunt
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.86-89
    • /
    • 2002
  • A new design approach for realising low-power low-voltage high-Q high-order RE bandpass filter is proposed. Based on the gyrator-C inductor topology, a 2$\^$nd/-order biquadratic bandpass filter can be realised by adding a series capacitor to the input port of the gyrator. High-Q 2$\^$nd/-order and 4$\^$th/-order fully differential RF bandpass filters operating in the 2.4-㎓ ISM (Industrial, scientific and medical) frequency band under a 2-V single power supply voltage with low power dissipation are reported.

  • PDF