• Title/Summary/Keyword: Infrared Furnace

검색결과 37건 처리시간 0.04초

THE ANALYSIS OF EFFLUENT GAS FROM ETHYLENE FURNACE BY NEAR-INFRARED SPECTROSCOPY

  • Lee, Joon-Sik;Kim, Jeong-Hyen;Cho, In-Ho
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1192-1192
    • /
    • 2001
  • Usually there are many furnaces in a ethylene plant and the performance of total furnaces can be improved if that of each furnace is monitored and controlled. For this purpose real-time data for the effluent of each furnace is necessary. However, it is very difficult to analyze the total effluent stream of a ethylene furnace by real-time because it is composed of so many components including heavy hydrocarbons. Fortunately, component data for lighter hydrocarbons is much more important than that of heavier ones for ethylene furnace. In ordinary case, the on-line measurement of light hydrocarbons is performed by on-stream gas chromatography, after separating gas-phase part from effluent. The main and important components of gas-phase are Methane, Ethane, Ethylene, and Propylene. If we can use Near-infrared spectroscopy for measuring those components within good reproducibility, shorter analysis time, better repeatability, easier maintenance and lower cost will make Near-infrared (NIR) analyzer replace on-stream gas chromatography in this process. Although it is known to be very difficult to measure gas components because of very weak absorption in Near-infrared region, we have studied the feasibility of the application of NIR for the measurement of gas-phase hydrocarbon in the effluent of ethylene furnace. The samples were obtained from actual process and NIR spectra were collected over 1100 to 2500nm range. NIR spectra and calibrations showed and demonstrated the possibility of extending NIR spectroscopy to the measurement of gas-phase hydrocarbon in the effluent of ethylene furnace.

  • PDF

피라미드 트러스형 금속 샌드위치 판재의 적외선 브레이징을 이용한 효율적 적층식 제작 및 특성에 관한 연구 (Efficient Layered Manufacturing Method of Metallic Sandwich Panel with Pyramidal Truss Structures using Infrared Brazing and its Mechanical Characteristics)

  • 이세희;성대용;양동열
    • 한국정밀공학회지
    • /
    • 제27권8호
    • /
    • pp.76-83
    • /
    • 2010
  • Metallic sandwich panels with pyramidal truss structures are high-stiffness and high-strength materials with low weight. In particular, bulk structures have enough space for additional multi-functionalities. In this work, in order to fabricate 3-D structures efficiently, Layered Manufacturing Method (LMM) which was composed of three steps, including crimping process, stacking process and bonding process using rapid infrared brazing, was proposed. The joining time was drastically reduced by employing infrared brazing of which heating rate and cooling rate were faster than those of conventional furnace brazing. By controlling the initial cooling rate slowly, the bonding strength was improved up to the level of strength by conventional vacuum brazing. The observation of infrared brazed specimens by optical microscope and SEM showed no defect on the joining sections. The experiments of 1-layered pyramidal structures and 2-layered pyramidal structures subject to 3-point bending were conducted to determine structural advantages of multilayered structures. From the results, the multi-layered structure has superior mechanical properties to the single-layered structure.

HDU를 이용한 적외선 LED CCTV의 LED 수명 향상을 위한 방열설계에 관한 연구 (A Study on Design of a Heat Dissipation to Improve the LED Lifetime for IR LED CCTV Using the HDU)

  • 이동규;김형진;곽준섭
    • 한국전기전자재료학회논문지
    • /
    • 제27권10호
    • /
    • pp.673-677
    • /
    • 2014
  • In this paper, thermal analysis of HDU (Heat Dissipation Unit) for infrared CCTV is performed by using SolidWorks Simulation (Thermal analysis) package, in order to change the part materials and HDU shape is optimized. Furthermore, HDU disperses the aggregated heat around the LED inside the housing. The junction temperature of infrared LED checked by HDU check was $65.83^{\circ}C$, $42.02^{\circ}C$, respectively. In addition, the Thermoelement by changing the shape of the HDU was possibly designed and equipped with. Comparison with simulation and prototype measurement results, without HDU model was $65.83^{\circ}C$, $61.99^{\circ}C$, respectively. In addition to with HDU model was $42.02^{\circ}C$, $39.01^{\circ}C$, respectively. Only HDU mounted into infrared CCTV is usable in the ordinary house or outdoors. Also HDU with thermal element, fan mounted into infrared CCTV is usable in a blast furnace workplace or high temperature workplace.

LPE GROWTH OF $La_{2-x}Sr_xCuO_4$ SINGLE-CRYSTALLINE FILMS

  • Tanaka, Isao;Tanabe, Hideyoshi;Watauchi, Satoshi;Kojima, Hironao
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1999년도 PROCEEDINGS OF 99 INTERNATIONAL CONFERENCE OF THE KACG AND 6TH KOREA·JAPAN EMG SYMPOSIUM (ELECTRONIC MATERIALS GROWTH SYMPOSIUM), HANYANG UNIVERSITY, SEOUL, 06월 09일 JUNE 1999
    • /
    • pp.371-387
    • /
    • 1999
  • La2-xSrxCuO4 single-crystalline films were prepared on bulk single crystals of Zn-doped La2CuO4 as the substrates by LPE technique using tow deferent methods. When prepared using an alumina crucible in normal electrical furnace, the La2-xSrxCuO4 films were contaminated with less than 3 at% aluminum from the alumina crucibles. Aluminum contamination either reduced or completely destroyed the superconductivity of the La2-xSrxCuO4 films. For LPE growthby modified TSFZ method using an infrared heating furnace without crucibles, the La2-xSrxCuO4 films of x=0.11 showed superconducting with Tconset 36 K, which is 10 K higher than that in the La2-xSrxCuO4 bulk single crystals.

  • PDF

알루미늄 판재의 성형성 향상을 위한 적외선 국부 열처리법의 곡선형태 적용에 관한 연구 (A Study on the Infrared Local Heat Treatment of Curved Line for Aluminum Alloy Sheet)

  • 이은호;양동열
    • 소성∙가공
    • /
    • 제27권2호
    • /
    • pp.87-92
    • /
    • 2018
  • Auto industries have tried to employ lightweight alloys to improve the fuel efficiency of manufactured vehicles, as the environmental concern becomes an important issue. Even though the aluminum alloy is one of the most appropriate lightweight alloys for auto parts, the low formability of an aluminum alloy has been an obstacle to its application. In order to resolve the low formability problem, a recent study (Lee et al., 2017 [1]) showed that the infrared (IR) local heat treatment can improve the formability with a reduction of heating energy. However, the aforementioned study was limited to only a linear line heating. Since many of the available auto parts as applicable to vehicle manufacturing have a curved line shape, the heating experiments for a curved line should be studied. The possibility of building IR lamps having complex shapes is an advantage of the IR lamp, since it can control the heating shape. This work conducted the IR local heat treatment for the curved line. The experimental results show that the IR local heat treatment can improve the formability of the aluminum alloy for curved line. Additionally, it is shown that the IR local heat treatment also reduces the heating energy when it is compared with the furnace heating which heats a blank as a whole. A numerical simulation with a stress-based forming limit diagram also supports the experimental results.

LPE growth of $La_{2-x}Sr_{x}CuO_{4}$ single-crystalline films

  • Tanaka, Isao;Tanabe, Hideyoshi;Watauchi, Satoshi;Kojima, Hironao
    • 한국결정성장학회지
    • /
    • 제9권3호
    • /
    • pp.299-302
    • /
    • 1999
  • $La_{2-x}Sr_{x}CuO_{4}$ single-crystalline films were prepared on bulk single crystals of Zn-doped $La_{2-x}Sr_{x}CuO_{4}$ as the substrates by LPE technique using two deferent methods. When prepared using an alumina crucible in normal electrical furnace, the $La_{2-x}Sr_{x}CuO_{4}$ films were contaminated with less than 3 at% aluminum from the alumina crucibles. Aluminum contamination either reduced or completely destroyed the superconductivity of the $La_{2-x}Sr_{x}CuO_{4}$ films, For LPE growth by modified TSFZ method using an infrared heating furnace without crucibles, the $La_{2-x}Sr_{x}CuO_{4}$ films of x=0.11 showed superconducting with $Tc_{onset}=36\;K$, which is 10 K higher than that in the $La_{2-x}Sr_{x}CuO_{4}$ bulk single crystals.

  • PDF

화염가수분해 증착 공정에서 기판온도의 변화에 따른 다성분 입자의 부착 및 소결특성에 관한 연구 (Effect of Substrate Temperature on Multi-component Particle Deposition and Consolidation in Flame Hydrolysis Deposition)

  • 신형수;백종갑;최만수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.428-433
    • /
    • 2000
  • The consolidation behavior of multicomponent particles prepared by the flame hydrolysis deposition process is examined to identify the effects of Si substrate temperature. To fabricate multi-component particles, a vapor-phase ternary mixture of $SiCl_4(100 cc/min),\;BCl_3(30cc/min)\;and\;POCl_3,(5cc/min)$ was fed into a coflow diffusion oxy-hydrogen flame burner. The doped silica soot bodies were deposited on silicon substrates under various deposition conditions. The surface temperature of the substrate was measured by an infrared thermometer. Changes in the chemical states of the doped silica soot bodies were examined by FT-IR(Fourier-transformed infrared spectroscopy). The deposited particles on the substrate were heated at $1300^{\circ}C$ for 3h in a furnace at a heating rate of 10K/min. Si-O-B bending peak has been found when surface temperature exceeds $720^{\circ}C$. Correspondingly, the case with substrate temperatures above loot produced good consolidation result.

  • PDF

인듐안티모나이드(InSb) 소자를 이용한 적외선 방사온도 계측시스템의 개발연구 (Development of Radiation Thermometer using InSb Photo-detector)

  • 황병옥;이원식;장경영
    • 한국정밀공학회지
    • /
    • 제12권7호
    • /
    • pp.46-52
    • /
    • 1995
  • This paper proposes methodologies for the development of radiation thermometer using InSb photo-detector of which spectral sensitivity is excellent over the wave length range of 2 .mu. m .approx. 5 .mu. m. The proposed radiation thermometer has broad measurement range from normal to high, up to more than 1000 .deg. C, with high accuracy, and can measure temperature on the material surface or heat emission noncontactely with high speed. Optical system was consisted of two convex lens with foruslength of 15.2mm for infrared lay focusing, Ge filter to cut the short wave length components and sapphire filter to cut the long wave length components. The cold shielded was installed in the whole surface of the light-absorbing element to remove the error- mometer, calibration using black body furnace which has temperature range of 90 .deg. C .approx. 1100 .deg. C was carried out, and temperature calaibration curve was obtained by exponential function curvefitting. The result shows maximum error less than 0.24%(640K .+-. 1.6K) over the measurement range of 90 .deg. C .approx. 700 .deg. C, and from this result the usefulness of the developed thermometer has been confirmed.

  • PDF

퓨리에 변환 적외선 분광기를 이용한 수직 분광 복사율 측정 장치의 제작과 측정 (Construction and Measurement of Normal Spectral Emissivity Device using Fourier Transform Infrared Spectrometer)

  • 전상호;유남준;조재흥;박철웅;박승남;이근우
    • 한국광학회지
    • /
    • 제19권6호
    • /
    • pp.400-407
    • /
    • 2008
  • 퓨리에 변환 적외선 분광기(FT-IR)를 이용한 물질의 적외선 분광 복사율 측정 장치를 구축하고 이 장치의 성능을 평가하였다. 본 장치는 기준 흑체, 시료 가열로, 광학계, FT-IR로 구성되어 있으며, 측정 온도 및 파장 영역은 $200^{\circ}C{\sim}500^{\circ}C$$3.5{\mu}m{\sim}20{\mu}m$ 이다. 기준 흑체의 유효 복사율은 0.9993 이상으로 거의 1에 가까운 값을 나타내고 있었으며, 흑체의 분광 복사율에 대한 합성 상대 불확도는 0.69% 이하이다. $300^{\circ}C$에서 불투명한 알루미나, 흑연, 양극 처리된 알루미늄 시료의 수직 분광 복사율과, 금속(IMS200)의 표면 거칠기에 따른 복사율을 측정하였다. 금속(IMS200)의 표면 거칠기에 따른 복사율 변화는 거칠기가 증가할수록 증가하였다.