• 제목/요약/키워드: Instrument system

검색결과 1,591건 처리시간 0.028초

Audiometric Calibration of Aural Acoustic Immittance Instrument: A Review of Acoustic Immittance Instrument's Calibration

  • Kim, Jin-Dong
    • 대한의생명과학회지
    • /
    • 제22권4호
    • /
    • pp.115-126
    • /
    • 2016
  • Audiometric calibration is a prerequisite for securing the reliability of audiometric test results by checking the internal consistency of the relevant instrument. The purpose of this review is to help instrument operators understand the calibration procedure of aural acoustic immittance instrument which is frequently used for objective assessment. By referring to the latest international standards and the national standards relevant to the aural acoustic immittance instrument, the following parameters will be reviewed: 1) introduction of performance characteristics, 2) detailed procedure of the calibration method. According to the newest international and national standards [IEC 60645-5 (2004), ANSI S3.39-1987 (R2012)], the aural acoustic immittance instrument basically includes six components: 1) calibration cavity, 2) acoustic immittance analysis system, 3) probe assembly/unit and signal, 4) pneumatic air-pressure pump system, 5) acoustic reflex activator system and 6) tympanogram and acoustic reflex plotting system, each of these components should meet set standards. The result of behavioral hearing tests is influenced by various complex factors including the examinee's cooperation, background noise of the examination room, measurement method, skill level of the audiologist and calibration status, but the objective hearing tests is more influenced by the calibration status of the instrument than any other factors. The audiologist should take full responsibility for the reliability of the hearing test result, so he/she should carry out the calibration check and adjustments of aural acoustic immittance instrument periodically and maintain the instrument continuously by referring to the newest standards and the manufacturer's instruction manual.

XML기반 과학교구 관리 시스템의 설계 및 구현 (Design and Implementation of a Science Instrument Management System based on XML)

  • 손병국;박판우
    • 정보교육학회논문지
    • /
    • 제13권2호
    • /
    • pp.117-126
    • /
    • 2009
  • 본 연구에서는 과학교구 관리 도구의 필요성에 따라 과학교구 데이터를 XML을 이용하여 목록화 하였으며 이를 효과적으로 활용하는 편리하고 활용성이 높은 XML기반 과학교구 관리 시스템에 관하여 연구하였다. 이를 통해 현재 수작업으로 관리되고 있는 과학교구 관리를 표준화 전산화 하여 언제 어디서든 쉽고 간편하게 과학교구를 관리 할 수 있는 관리 시스템을 개발하였다.

  • PDF

Influence of Atmospheric Turbulence Channel on a Ghost-imaging Transmission System

  • Wang, Kaimin;Wang, Zhaorui;Zhang, Leihong;Kang, Yi;Ye, Hualong;Hu, Jiafeng;Xu, Jiaming
    • Current Optics and Photonics
    • /
    • 제4권1호
    • /
    • pp.1-8
    • /
    • 2020
  • We research a system of compressed-sensing computational ghost imaging (CSCGI) based on the intensity fluctuation brought by turbulence. In this system, we used the gamma-gamma intensity-fluctuation model, which is commonly used in transmission systems, to simulate the CSCGI system. By setting proper values of the parameters such as transmission distance, refractive-index structure parameter, and sampling rates, the peak signal-to-noise ratio (PSNR) performance and bit-error rate (BER) performance are obtained to evaluate the imaging quality, which provides a theoretical model to further research the ghost-imaging algorithm.

의료기기 분야 정보화관리시스템 구축 (The Construction of the Database System In the Field of Medical Instrument)

  • 이승철;김지운;김세훈;김윤수;박상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2451-2453
    • /
    • 1998
  • With the recent trend to get more into the information age we suppose that the need of information for medical industry policy establishment and new product development of medical instrument will increase rapidly. The object of this research & development is the construction of a database system with information resources in the field of medical instrument for an efficient application of domestic and abroad information in the field of medical instrument and building the foundation for the construction of an unified information management system. In this research we finished the analysis of the collected material of informations for medical instrument industry, design of the database system with object-oriented modelling is done. and we developed pre-product level information management system running on WINDOWS.

  • PDF

스마트폰을 이용한 지능형 건반악기 자율학습 시스템 (Intelligent Self Learning System for Keyboard Instrument using a Smartphone)

  • 김영근;김원중
    • 한국전자통신학회논문지
    • /
    • 제9권9호
    • /
    • pp.999-1004
    • /
    • 2014
  • 본 논문에서는 초보자들도 건반악기의 연주 방법을 쉽고, 효과적으로 학습할 수 있도록 건반악기 자율 학습 시스템을 개발하였다. 본 연구에서 개발한 지능형 건반악기 자율 학습시스템은 스마트폰 기반의 학습 어플리케이션과 건반악기 보조 모듈로 구성된다. 건반악기 보조 모듈은 스마트폰 어플리케이션과 블루투스 통신을 통하여 악기 연주 정보를 수신한 후, LED에 표시해 줌으로써 초보자도 쉽게 건반과 음계의 상관관계를 숙지할 수 있도록 하였다. 또한 사용자의 연주정보를 저장하고, 분석 정보를 제공하여 효과적인 학습이 가능하도록 구현하였다.

계측시스템에 의한 저수지 제체의 안정성 평가 (Safety Evaluations of Reservoir Embankment by Instrument System)

  • 김미현;이달원
    • 한국농공학회논문집
    • /
    • 제51권6호
    • /
    • pp.33-43
    • /
    • 2009
  • This study analyzed data on the pore water pressure, the ground water level, the horizontal displacement and the resistivity monitoring from instrument system, which is established to evaluate the safety in reservoirs. The pore water pressure in the embankment ranged from $0.035{\sim}1.116kg/cm^2$. The seepage that piping showed, as well as the leakage from the reservoirs are acceptable for the safety management of the reservoir. The maximum horizontal displacement and direction analyzed from the measured inclinometer data gives us very effective information to evaluate the safety in reservoirs. The resistivity monitoring technique, which is obtained on the reservoir crest, is an efficient tool to detect leakage zone. The safety index (SI) was predicted by the resistivity monitoring, and was evaluated to have a safety level of 0.8-1.0 at all reservoirs. Safety evaluations of reservoir through instrument systems are effective when studying the embankment, when the results of the instrument system have been analyzed compositively.

계측시스템에 의한 저수지 제체의 안정성 평가 (Safety Evaluations of Reservoir Embankment by Instrument System)

  • 이달원;김미현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.840-851
    • /
    • 2010
  • This study analyzed data on the pore water pressure, the ground water level, the horizontal displacement and the resistivity monitoring from instrument system, which is established to evaluate the safety in reservoirs. The pore water pressure in the embankment ranged from $0.035{\sim}1.116kg/cm^2$. The seepage that piping showed, as well as the leakage from the reservoirs are acceptable for the safety management of the reservoir. The maximum horizontal displacement and direction analyzed from the measured inclinometer data gives us very effective information to evaluate the safety in reservoirs. The resistivity monitoring technique, which is obtained on the reservoir crest, is an efficient tool to detect leakage zone. The safety index(SI) was predicted by the resistivity monitoring, and was evaluated to have a safety level of 0.8-1.0 at all reservoirs. Safety evaluations of reservoir through instrument systems are effective when studying the embankment, when the results of the instrument system have been analyzed compositively.

  • PDF

FSK와 ASK 조합형 수중 초음파 원격제어시스템 개발 (A Development of a Remote Control System for Marine Instrument Using the Combination of FSK and ASK)

  • 김영진;정한철;허경무;조영준;민병국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.186-188
    • /
    • 2006
  • To secure abyssal resources, submarine environment should be firstly explored. On that occasion, the withdrawal of the instrument is of importance and the submarine ultrasonic wave should be stably identified regardless submarine environment and passive factor. In the existing control methods, the control informations, received from an observation instrument, are identified used by hardware and repeatedly compared with standard information. Hereupon, a marine observation instrument remote control system using the combination of FSK and ASK that was improved its controllability and movability was presented in this paper. Likewise, the logicality of control algorithm and remote control system were ascertained by experiments.

  • PDF

고속 중형 컴퓨터 통합 시험 및 성능 분석을 위한 버스 감시기의 설계 및 구현 (Design and Implementation of a Bus Monitoring Instrument for the TICOM-III Integration Test and Performance Analysis)

  • 한종석;송용호
    • 전자공학회논문지B
    • /
    • 제32B권8호
    • /
    • pp.1064-1073
    • /
    • 1995
  • On a bus-based shared memory multiprocessing system, the system bus monitoring and analysis are crucial for system integration test and performance analysis. In this paper, the design and implementation of a bus monitoring instrument for the TICOM-III system are decribed. The instrument dedicated to TICOM-III, which is called the Bus Information Procssing Unit, analyzes the bus state and measures the bus utilization. It performs many useful functions to help debugging the system, and offers a simple user interface.

  • PDF

A Ghost-Imaging System Based on a Microfluidic Chip

  • Wang, Kaimin;Han, Xiaoxuan;Ye, Hualong;Wang, Zhaorui;Zhang, Leihong;Hu, Jiafeng;Xu, Meiyong;Xin, Xiangjun;Zhang, Dawei
    • Current Optics and Photonics
    • /
    • 제5권2호
    • /
    • pp.147-154
    • /
    • 2021
  • Microfluidic chip technology is a research focus in biology, chemistry, and medicine, for example. However, microfluidic chips are rarely applied in imaging, especially in ghost imaging. Thus in this work we propose a ghost-imaging system, in which we deploy a novel microfluidic chip modulator (MCM) constructed of double-layer zigzag micro pipelines. While in traditional situations a spatial light modulator (SLM) and supporting computers are required, we can get rid of active modulation devices and computers with this proposed scheme. The corresponding simulation analysis verifies good feasibility of the scheme, which can ensure the quality of data transmission and achieve convenient, fast ghost imaging passively.