애자표면의 오손물 누적에 관한 메커니즘 연구 (A Study on Mechanism about Contaminant Accumulation of Insulator Surface)

  • 박재준
    • 정보학연구
    • /
    • 제8권2호
    • /
    • pp.85-91
    • /
    • 2005
  • We studied a pollution mechanism for simulation of contamination environment in industrial concentrated area of around a metropolitan that made to circulated flow in the chamber. In case of the virgin both side of EPDM or Silicon insulator, we confirmed that the pollution to much more than service insulator in the field. Also contamination of initial state of the virgin didn't falling in spite of physical outside factor easily. This study confirmed to that the silicon was too much accumulated pollution contrast to EPDM insulator from scatter(spray) point to regular interval position use the Kaolin contaminant in the chamber. There are effected to the hydrophobicity of polymer insulator due to the pollution. In ceramic insulator, we get to know that pollution is much more at the Post insulator with vertical than with horizontal setup insulator.

  • PDF

현수/내장애자련 겸용 활선애자 점검로봇 시스템 개발 (Development of Live-line Insulator Inspection Robot System for both Suspension and Tension Insulator Strings)

  • 박준영;이재경;오기용
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1239-1244
    • /
    • 2011
  • In our previous paper, we developed an insulator inspection robot system for a suspension insulator string in the 345kV power transmission line. However, this robot cannot be applied to a tension insulator string, because its constituent insulators are different in diameter and height from those of a suspension insulator string. To solve this problem, we developed a new live-line insulator inspection robot system that is applicable to both suspension and tension insulator strings. We confirmed its effectiveness through live-line performance tests.

전철용 고분자 장간애자 실용화 (Installation of Polymer Stem Insulator for Electric Railway)

  • 김수연;이상진;김영성;김동욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.352-359
    • /
    • 1999
  • Polymer stem insulator for an electric railway has been developed in 1995 in Korea. Owing to its excellent electrical and physical characteristics, KT mark was awarded for the developed polymer stem insulator. After new specification of KNR(Korea National Railway) was established, tile evaluation of long-term reliability combined with the improvement of manufacturing process was carried out. In 1998, this polymer stem insulator was installed in commercial electrical railway line. This paper presents the long-term reliability properties of the installed polymer stem insulator compared with conventional insulator. The location of tile installed polymer stem insulator in KNR is also introduced.

  • PDF

내마모성이 우수한 절연구분장치 국산화 개발 (Development of Section Insulator with Improved Wear Characteristics)

  • 이기원;정호성;박영;조호령;이상식
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1633-1639
    • /
    • 2013
  • In a section of AC electric railway, a phase between the sections is different although voltage levels supplied from substations are the same. Therefore, section insulators have been installed to electrically divide between the sections. Two differenet types of section insulator, namely an overlap type and insulator type, are used. In Korean high-speed lines, overlap type section insulator has been adopted. And, insulator type is used in conventional line. The overlap type has the advantage of having no speed limit, but has the disadvantage of requiring long section length. However, the insulator type has the advantage of section length, but also has the disadvantage of having speed limit. In Korean conventional line, an insulator type one relies on the import and there is some problem with wear. In this study, we developed the insulator type section insulator which adopts Teflon tube insulation material. The Teflon material has advantage of the excellent electrical characteristics and wear-resistance characteristics for a longer expected life than that made of existing FRP. In order to compare wear characteristics between the materials, wear tests with reciprocal wear tester are performed. And dynamic behavior tests between the insulators and pantograph are also performed for showing its better dynamic characteristics.

송전선로 활선 애자 청소 및 점검용 로봇 기구부의 개발 (Development of Robot Mechanism for Cleaning and Inspection of Live Line Insulator)

  • 박준영;조병학;변승현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.421-423
    • /
    • 2005
  • Power transmission lines have been playing a key role as the mainstay of national industry. When a power failure occurs, it can have severe effects on national security as well as national industry and economy. In this paper, we consider an insulator failure, which is one of the main causes of such a power failure. In spite of its importance, however, a shortage of manpower in the insulator maintenance field is getting more serious due to working environments with a high voltage and a high place. For this reason, a new active maintenance technique using a robot system is required to prevent such an insulator failure. In this paper, a new robot mechanism for insulator cleaning and inspection was developed. We confirmed its effectiveness through experiments.

  • PDF

송전용 폴리머 애자의 산불 모의시험에 따른 표면열화 특성 (Surface Ageing Property of Polymer Insulator for Transmission line with Forest Fire Test)

  • 조한구;김광용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.110-110
    • /
    • 2010
  • Suspension insulator have made use of porcelain insulator mainly, but polymer insulator is using recently. Polymer suspension insulator have advantage that it is light than porcelain insulator. The ageing performance is excellent and it is possible for mass production. There is high possibility of mountain fire because a lot of potential inflammables such as fallen leaves are stacked on the ground Therefore surface aging of polymer insulator most of the overhead transmission lines in Korea are operated on the mountain need analysis of transmission line into forest fire. surface aging property is analyzed by SEM, EDX, XPS, FTIR, DSC in this paper.

  • PDF

전륜 Insulator 이음 개선을 위한 강건 구조 방안 연구 (A Study On The Robust Structure For Improvement of Front Insulator Noise Improvement)

  • 이상종
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제17권3호
    • /
    • pp.197-206
    • /
    • 2017
  • Purpose: Clarify the cause of the noise by the front wheel strut insulator, which is located in close proximity to the driver's seat. Methods: The improvement mechanism was confirmed through failure analysis and reproduction test of the joint generation mechanism. In addition, the main factors were analyzed through principal test. Results: This paper describes the mechanism of occurrence of noise due to deterioration and hardness increase of rubber, deformation on severe road surface, foreign matter and water inflow in cold weather. Conclusion: We found that the insulator and body deformation can be minimized without increasing the thickness of the body and the insulator and reinforcing the body by dispersing the input load by applying load distribution structure instead of the local forming structure of the insulator in the insulator robust structure.

FEM을 이용한 400kN 현수애자의 절연특성 해석 (Analysis of Dielectric Characteristics of 400kN Suspension Insulator Using FEM)

  • 최재구;김익수;문인욱;서형권
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권2호
    • /
    • pp.80-84
    • /
    • 2002
  • This paper presents some of the results of current research on 400kN Suspension Insulator Design. In this paper, authors carried out 2-dimensional field calculation in order to analyse dielectric characteristics of the insulator unit and 3-dimensional field calculation in order to analyse dielectric characteristics of the insulator strings. And the results of puncture tests of insulators were compared with the required field intensity of the insulator As results, it was found that electric field on the insulator unit is severest between two triple junctions, dielectric characteristics of insulator strings are much influenced by the surrounding configuration and the manufactured insulators have good results of puncture tests.

고속철도 유리애자 파손원인을 위한 현장 진동 연구 (A Study on Field Vibration for Fault Cause Analysis of Glass Insulator on High-speed Railway)

  • 김영석;송길목;방선배;김선구;류영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 합동춘계학술대회 논문집 전기물성,응용부문
    • /
    • pp.189-190
    • /
    • 2008
  • This study was investigated a possibility of fault of glass insulator due to vibration on high-speed railway. The proper vibration of 1-glass insulator have many frequency band and high amplitude showed in high frequency than low frequency. The proper vibration of strut tube insulator was lowest 170Hz, highest 1.5kHz. The field signal amplitude of viaduct and open route were biggest moment pantograph of high-speed rail. The surface vibration(V3) amplitude of strut tube insulator was biggest. From the FFT analysis of viaduct and open route, the strut tube insulator effect by vertical vibration was big, the frequency was 82.5Hz and 105Hz, respectively. However, in comparison with the proper vibration of strut tube insulator, the resonance was not observed. Although the amplitude of insulator is high, the possibility of fault is low because the glass insulator deterioration by the accumulation of vibration do not happen.

  • PDF

폴리머 현수애자의 복합가속열화 평가기술 (Multi-Stress Aging Test Technology for Suspension Polymer Insulator)

  • 박효열;강동필;김익수;신영준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.481-484
    • /
    • 2003
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators have significant advantages over porcelain and glass insulators. With the gradual improvement of their design and material, their reliability has also increased. It is however difficult to establish how they will perform after several years of service. Aging of the insulator weathershed may lead to damages such as excessive chalking and crazing, erosion and tracking which affect the insulator performance. In service insulator are subjected to aging stresses such as humidity, pollution and electrical field which act singly or in combination. There have been numerous accelerated laboratory tests developed with the intention of evaluating suitability of polymeric materials. Some of these are strictly material tests, where as, others evaluate full scale devices. Service experience plays a key role in the utility selection of polymer insulator, but is time consuming, and may not always be available. Hence there is a need for a meaningful and reliable accelerated aging test for polymer insulator. This paper describes multi-stress aging test for reliability of polymer insulator This paper presents the rule of multi-stress aging test and test chamber for polymer insulator in korea electrotechnology research institute.

  • PDF