• 제목/요약/키워드: Internal defects

Search Result 504, Processing Time 0.028 seconds

A Study on the single crystal growth of the optic-grade $LiTaO_3$ as a electro-optic materials

  • Kim, B.k.;J.K. Yoon
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06a
    • /
    • pp.526-526
    • /
    • 1996
  • The single crystal of LiTaO3 is well known eletro-optic material as well as the piezoelectric one applied to SAW filter. LiTaO3 has large electro-optic effects, so applied to optical switch, acosto-optic deflector, and optical memory device using photorefractive effects. The crystal growth of SAW-grade LiTaO3 has been studied many aspects, but there is no detail research about optic-grade crystal growth. The conditions of optic-grade LiTaO3 single crystal are as below. The optical transmittance must be over 75%, and axial and radial concentratiom uniformity below 1%. The variation of Curie temperature depending on Li/Ta ratio must be also below 2$^{\circ}C$ and no internal no internal cracks and defects. Because of the limitation of crystal quality, the growing of optic-grade LiTaO3 single crystal is very difficult compared with the growing of SAW-grade. In this research, upper conditions of optic-grade single crystal was investigated after growing of 1 inch diameter and 1.5 inch length LiTaO3 single crystal having no internal cracks and defects using Czochralski method. Curie temperature was determined with DSC and measuring capacitance and lattice parameter was calculated about the grown crystal and ceramic powder samples of various Li/Ta ratio. The result of Tc variation was below 1.2$^{\circ}C$ all over the grown crystal, so it is confirmed that LiTaO3 was grown under congruent melting composition having optical homogeniety. Also, the optical transmittance was about 78%, which was sufficient for optical device.

  • PDF

Side Effects of Orthopedic Products in Veterinary Medicine in South Korea

  • Yun, Taesik;Jung, Soo Yeon;Kang, Kyongmook;Yun, Seon-Jong;Koo, Yoonhoi;Park, Jooyoung;Kim, Ill-Hwa;Kang, Hyun-Gu
    • Journal of Veterinary Clinics
    • /
    • v.39 no.1
    • /
    • pp.9-15
    • /
    • 2022
  • As more veterinary clinics become specialized with the growth of the companion animal market, an increasing number of veterinary clinics perform orthopedic surgery and use orthopedic products, some of which are defective and have side effects. Thus, the present study aimed to prepare fundamental data for the revision and development of manufacturing standards for these products in order to prevent their side effects. We conducted a survey targeting veterinary clinics as consumers and medical device companies as suppliers. Veterinary clinics were surveyed via offline and online methods; 320 clinics that offered orthopedic surgery and approximately 4,000 veterinary clinics that were registered in the Korean Veterinary Medical Association were targeted, and 153 veterinary clinics responded to the survey. The survey for medical device companies, was performed online, targeting 29 companies; 14 companies responded. The number of side effects of orthopedic products was higher in animal orthopedic products than in those for human use. Many consumers tended to suspect that side effects were caused by product defects. To resolve side effects after using orthopedic products, consumers mostly underwent reoperation. Meanwhile, some severe cases proceeded to legal disputes. Similarly, medical device companies, or the suppliers, responded that most side effects occurred in veterinary orthopedic products and that product defects and mistakes in use were the causes. As for most of the follow-up actions for side effects, these companies either reported the issue to those in charge or analyzed and resolved the issues themselves. Therefore, to develop quality products, suppliers should be provided with clear standards for the production, and information disclosure and a report system for side effects should be particularly established to gain consumers' trust regarding the safety of these products.

Endoscopic Intervention for Anastomotic Leakage After Gastrectomy

  • Ji Yoon Kim;Hyunsoo Chung
    • Journal of Gastric Cancer
    • /
    • v.24 no.1
    • /
    • pp.108-121
    • /
    • 2024
  • Anastomotic leaks and fistulas are significant complications of gastric surgery that potentially lead to increased postoperative morbidity and mortality. Surgical intervention is reserved for cases with severe symptoms or hemodynamic instability; however, surgery carries a higher risk of complications. With advancements in endoscopic treatment options, endoscopic approaches have emerged as the primary choice for managing these complications. Endoscopic clipping is a traditional method comprising 2 main categories: through-the-scope clips and over-the-scope clips. Through-the-scope clips are user friendly and adaptable to various clinical scenarios, whereas over-the-scope clips can close larger defects. Another promising approach is endoscopic stent insertion, which has shown a high success rate for leak closure, although vigilant monitoring is required to monitor stent migration. Infection control is essential in post-surgical leakage cases, and endoscopic internal drainage provides a relatively safe and noninvasive means to manage fluids, contributing to infection control and wound healing promotion. Endoscopic suturing offers full-thickness wound closure, but requires additional training and endoscopic versatility. As a promising tool, endoscopic vacuum therapy potentially surpasses stent therapy by draining inflammatory materials and closing defects. Furthermore, the use of tissue sealants, such as fibrin glue and cyanoacrylate, has been reported to be effective in selected situations. The choice of endoscopic device should be tailored to individual cases and specific patient conditions, with careful consideration of the nature of the defect. Further extensive studies involving larger patient populations are required to provide more robust evidence on the efficacy of endoscopic approach in managing post-gastric anastomotic leaks.

Radioisotope Perfusion Lung Scanning in Takayasu's Arteritis (Takayasu 동맥염에서 폐관류스캔에 관한 연구)

  • Park, Seok-Gun;Bom, Hee-Seung;Oh, Yeon-Sang;Han, Jin-Suk;Chung, June-Key;Choi, Sung-Jae;Kim, Byung-Kook;Lee, Jung-Sang;Lee, Young-Woo;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.2
    • /
    • pp.73-78
    • /
    • 1986
  • Of 18 patients with Takayasu's arteritis who underwent $^{99m}Tc-MAA$ (macroaggregated albumin) perfusion luing scanning, 9 (50%) showed perfusion defects. Chest X-rays of them were nonspecific. One patient underwent $^{99m}Tc-DTPA$ radio aerosol inhalation lung scanning simultaneously, which revealed normal. So routine screening radioisotope perfusion lung scanning is helpful to evaluate pulmonary arterial involnmement in Takayasu's arteritis patients. And Takayasu's arteritis should be included in differential diagnosis of pulmonary embolism.

  • PDF

A Study on the Size Evaluation of Disc and Band Type Flaw by Ultrasonic Tandem Testing (초음파(超音波)TANDEM사각법(斜角法)에 의한 원형(圓形) 및 띠형결함(形缺陷)의 크기 평가(評價)에 관한 연구(硏究))

  • Han, E.K.;Eom, H.S.;Kim, J.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.5 no.2
    • /
    • pp.12-21
    • /
    • 1986
  • Generally, butt welds with plate thickness $30{\sim}40mm$ are welded with groove angle $40^{\circ},\;60^{\circ},\;70^{\circ}$, etc. In the detection of internal weld defects, oblique testing with single probe has been mainly used. But, recently, in acccordance with enlargement of welded structure, thick plate with 100-200mm are frequently required. Thus I-groove welding method was lately developed and often used. In this case, most frequently generated defects are the lack of weld penetration and incomplete fusion between base metal and welding material. If we would detect by oblique testing with single probe, detecting flaw is occassionally impossible or very underestimated. In this study, the limit for applying tandem method was studied in dise and band type flaws. The estimation of flaw size could be within 10% error compared to real flaws.

  • PDF

A Study on the U-bending of Rectangular Hollow Tube by the Eccentric Extrusion and Bending Process (편심압출굽힘가공법에 의한 사각형 단면을 가진 중공 튜브제품의 U형굽힘가공에 관한 연구)

  • Kim, Jin-Hoon;Jin, In-Tai
    • Transactions of Materials Processing
    • /
    • v.7 no.5
    • /
    • pp.496-504
    • /
    • 1998
  • The eccentric extrusion and bending process for the forming of the curved rectangular hollow tube is newly developed. Generally the bending process of hollow tube is the secondary process followed by the extrusion process of the hollow tube from the round billet. So many defects such as wrinkling and the difference of wall thickness can be happened during the secondary bending process. In order to avoid the defects the new process named as "the eccentric extrusion and bending process" is suggested and applied to the U-bending of rectangular hollow tube. In this paper the kinematically admissible velocity field between the dies surface and the internal plug boundary surface s developed for the curving velocity. By the using of this curving velocity field the curvature of extruded products can be calculated with the parameters such as eccentricity dies length friction constant aspect ratio.

  • PDF

Rail Inspection Using Noncontact Laser Ultrasonics

  • Kim, Nak-Hyeon;Sohn, Hoon;Han, Soon-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.6
    • /
    • pp.696-702
    • /
    • 2012
  • In this study, a noncontact laser ultrasonic system is proposed for rail defect detection. An Nd-Yag pulse laser is used for generation of ultrasonic waves, and the corresponding ultrasonic responses are measured by a laser Doppler vibrometer. For the detection of rail surface damages, the shape of the excitation laser beam is transformed into a line. On the other hand, a point source laser beam is used for the inspection of defects inside a rail head. Then, the interactions of propagating ultrasonic waves with defects are examined using actual rail specimens. Amplitude attenuation was mainly observed for a surface crack, and reflections were most noticeable from an internal damage. Finally, opportunities and challenges associated with real-time rail inspection from a high-speed train are discussed.

HVOF Thermal Sprayed AISI316-WC Coating Layer on Stainless Steel for PEMFC Bipolar Plate (고분자 전해질 연료전지용 분리판으로서 스테인리스강에 HVOF 용사된 AISI316-WC 코팅층)

  • Nam, Dae-Geun
    • New & Renewable Energy
    • /
    • v.4 no.1
    • /
    • pp.31-36
    • /
    • 2008
  • Stainless steels have been widely considered as metallic bipolar plates, due to their passive surface film, which is good for corrosion resistance. However, the high resistivity of the passive film increases interfacial contact resistance between the bipolar plates and the electrodes. Stainless steels thermal spray coated with a mixture of tungsten carbide and stainless steel powders showed that the coated layer safely combined with the matrix but they suffered many internal defects including voids and cracks. Many cracks were formed in the coated layer and the interface of the matrix and the coated layer during the rolling process. The coated and rolled stainless steels showed lower interfacial contact resistance and corrosion resistance than bare stainless steel because of low resistivity of tungsten carbide and numerous defects, which caused crevice corrosion, in the coated layer.

  • PDF

Effects of Asymmetric Distribution of Charged Defects on the Hysteresis Curves of Ferroelectric Capacitors

  • Lee Kang-Woon;Kim Yong-Il;Lee Won-Jong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.3 s.36
    • /
    • pp.219-226
    • /
    • 2005
  • When a ferroelectric film has an inhomogeneous distribution of charged defects, a voltage shift in the polarization curve is induced by the internal field generated in the film. The direction and the magnitude of voltage shift in the P-V hysteresis curves obtained by the Sawyer-Tower method are different from those obtained by the virtual ground method. In this study, the asymmetric behavior in the P-V hysteresis curves of inhomogeneous ferroelectric films was investigated with a physical model and the polarization curves obtained by the Sawyer-Tower and the virtual ground methods are compared.

  • PDF

Case Study for Developing Automobile Part (Steering Wheel) using Vacuum Die-Casting Mold (진공다이캐스팅 공법을 이용한 자동차용 조향장치 개발에 대한 사례연구)

  • Kwon, Hong-Kyu;Jang, Moo-Kyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.2
    • /
    • pp.196-203
    • /
    • 2012
  • When manufacturing die casting mold, generally, the casting layout design should be considered based on the relation between injection system, casting condition, gate system, and cooling system. Also, the extent or the location of product defects were differentiated according to the various relations of the above conditions. High-qualified products can be manufactured as those defects are controled by the proper modifications or the changes of die casting mold with the conditions. In this research, the proper manufacturing method was derived intensively for reducing the defect of the internal porosity of steering wheel housing which is very complicated to achieve a good mold design. The method was also derived for minimizing and for guaranteeing the product quality through the analysis of the casting problem and the deduction of alternative plans.