• Title/Summary/Keyword: Internal flow

Search Result 2,471, Processing Time 0.033 seconds

A Study of Performance and Internal Flow in a New Type of Sewage Pump

  • Nishi, Yasuyuki;Fukutomi, Junichiro
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.3
    • /
    • pp.239-247
    • /
    • 2009
  • Sewage pumps are designed with a wide flow channel by, for example, sacrificing some efficiency and reducing the number of blades, in order to prevent plugging with foreign bodies. However, the behavior of foreign bodies which actually flow into a pump is extremely complex, and there are questions about whether the presumed foreign bodies will actually pass through. This paper proposes a new type of sewage pump impeller designed to further improve pump efficiency and performance in passing foreign bodies. This sewage pump impeller has a structure in which the suction flow channel of a closed type non-clog pump is wound in a helical spiral. The focus of this research was to investigate pump performance and internal flow in this single blade sewage pump impeller. The results clearly indicated the following facts: The developed sewage pump impeller exhibits high efficiency over a wide range of flow rates; internal flow of the pump is very complicated; and the internal flow state varies greatly when the flow rate changes.

Internal Flow Characteristics of a Francis Hydro Turbine Model by Internal Flow Passage Shapes

  • Chen, Zhenmu;Wei, Qingsheng;Singh, Patrick Mark;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.5
    • /
    • pp.19-25
    • /
    • 2015
  • As a core component of a hydropower station, hydro turbines play a vital role in the integration of a power station. Research on the technology of hydro turbine is continuously increasing with the development of water electricity. On the basis of one-dimensional loss analysis, for three-dimension design, there are a lot of dimension of the internal flow passage shapes that are determined by experience. Therefore, the effect of the internal flow passage shapes on the performance and internal flow characteristics of a Francis hydro turbine model is investigated in this study. In this study, the small curvature of runner blade trailing edge shape is good for improving the efficiency of Francis turbine. The straight stay vane leading edge is good for suppressing the secondary flow. Moreover, suitable tongue passage shape and stay vane number improve the performance of the turbine considerably.

Effect of bidirectional internal flow on fluid.structure interaction dynamics of conveying marine riser model subject to shear current

  • Chen, Zheng-Shou;Kim, Wu-Joan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.4 no.1
    • /
    • pp.57-70
    • /
    • 2012
  • This article presents a numerical investigation concerning the effect of two kinds of axially progressing internal flows (namely, upward and downward) on fluid.structure interaction (FSI) dynamics about a marine riser model which is subject to external shear current. The CAE technology behind the current research is a proposed FSI solution, which combines structural analysis software with CFD technology together. Efficiency validation for the CFD software was carried out first. It has been proved that the result from numerical simulations agrees well with the observation from relating model test cases in which the fluidity of internal flow is ignorable. After verifying the numerical code accuracy, simulations are conducted to study the vibration response that attributes to the internal progressive flow. It is found that the existence of internal flow does play an important role in determining the vibration mode (/dominant frequency) and the magnitude of instantaneous vibration amplitude. Since asymmetric curvature along the riser span emerges in the case of external shear current, the centrifugal and Coriolis accelerations owing to up- and downward internal progressive flows play different roles in determining the fluid.structure interaction response. The discrepancy between them becomes distinct, when the velocity ratio of internal flow against external shear current is relatively high.

Internal Mammary Artery Grafting Without Intraluminal Dilatation - Measurement of Internal Mammary Artery Flow and Clinical Results - (내경 확장을 시행하지 않은 내유동맥을 이용한 관상동맥 우회로술의 임상적 결과[내유동맥 혈류량과 그임상적 결과])

  • 최종범
    • Journal of Chest Surgery
    • /
    • v.25 no.3
    • /
    • pp.307-314
    • /
    • 1992
  • The internal mammary artery has been advocated for use in bypass grafting owing to its superior long-term patency when compared to saphenous vein grafts. Concern exists that the flow through internal mammary artery may be inadequate during periods of peak myocardial demand when the internal mammary artery graft was used for proximal left anterior descending artery stenosis. This flow adequacy was investigated in 13 consecutive patients with a mean proximal left anterior descending artery stenosis of 84.2% who were selected for coronary bypass using internal mammary artery. We checked flow and diameter of left internal mammary artery without intraluminal dilatation just before anastomosis to left anterior descending artery during cardiopulmonary bypass. Clinical results were evaluated postoperatively with clinical symptoms, echocardiographies, stress tests, and coronary angiographies. The mean internal mammary artery flow measured just before anastomosis was 38ml/ min[range of 20 to 80ml /min] and its mean internal diameter 1.4mm. Maximal workload was improved from preoperative value of 6.3$\pm$2.5METS to postoperative value of 9.1$\pm$1.4 METS in 9 patients who Paired-test can be used. Cardiac symptoms recurred in two patients after bypass surgery, but they were not related to left internal mammary artery grafts. All patients were discharged in postoperatively 9.3 days[range of 7 to 20 days] after operation without mortality. Thus, on the basis of these findings, the internal mammary artery is a reasonable graft that we can routinely use for proximal left descending artery stenosis if internal diameter of the internal mammary artery is more than 1.0mm and its flow is more than 20ml /min at mean arterial pressure of 50 to 60mmHg during cardiopulmonary bypass.

  • PDF

The Effect of Jeongcheonhwadam-tang on Peak Expiratory Flow in Chronic Pulmonary Disease Patient with Dyspnea (호흡곤란을 동반한 만성호흡기질환 환자에서 정천화담탕이 최고호기유속에 미치는 영향(影響))

  • Heo, Tae-Yool;Im, Jae-Hyung;Park, Dong-Il
    • The Journal of Internal Korean Medicine
    • /
    • v.26 no.4
    • /
    • pp.875-880
    • /
    • 2005
  • Object : Dyspnea is a one of the common symptom in pulmonary disease. Jungchunghwadam-tang was used to treat chronic pulmonary disease patients with dyspnea. Thus in this study we evaluate the effect of Jungchunghwadam-tang on dyspnea. Methods : In this study, ten chronic pulmonary disease patients were treated with Jungchunghwadam-tang. Peak expiratory flow were obtained by peak flow meter. Result : After the treatment, peak expiratory flow was increased significantly compared with before treatment. Percentage of predict peak expiratory flow was also increased significantly compared with before treatment. Conclusion : The result of this study demonstrate that Jungchunghwadam-tang taken for dyspnea on chronic pulmonary disease are effective. Further investigation in well designed follow up study is needed.

  • PDF

Flow Characteristics of Cryogenic Butterfly Valve for LNG Carrier (Part 1 : CFD Analysis and its Comparison with Experimentation) (LNG선용 버터플라이밸브의 유동특성에 관한 연구 (제1부 : CFD해석과 실험결과의 비교))

  • Kim, Sang-Wan;Choi, Young-Do;Kim, Jung-Hwan;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.2
    • /
    • pp.13-19
    • /
    • 2008
  • Butterfly valves are widely used as control valves for industrial process. For the definition of optimum configuration of the valve, wide range of related studies has been actively conducted in the case of working fluids of water or air under the normal temperature. Recently, internal flow and performance characteristics of cryogenic butterfly valve for LNG carrier take a growing interest in the field of research and development. Therefore, present study is aimed to investigate the internal flow and performance characteristics of the cryogenic butterfly valve because the study result for the valve can be hardly found at present. Part 1 of this paper describes the study result of a butterfly valve model under the condition of the normal temperature. Succeeding Part 2 of this paper will describe the internal flow characteristics of a cryogenic butterfly valve for LNG carrier. The results of Part 1 show that pressure loss coefficients and flow rate coefficients obtained by the present experiment and CFD analysis agree well each other. Moreover, internal flow visualization for the valve by CFD analysis and PIV measurement have revealed complicated flow patterns of the internal flow field in detail.

Prediction of the internal flow in a pintle nozzle for LPG engine (LPG 엔진용 고압 핀틀노즐 내부유동 수치해석)

  • Jeong, Hong-Cheol;Kim, Byeong-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.8
    • /
    • pp.1077-1085
    • /
    • 1997
  • The use of "clean fuels" such as butane, propane, and mixtures of these (LPG) is an attractive way to reduce exhaust emissions. In this study internal flow of the pintle type injector for LPG engine is studied. The breakup of liquid jet is the result of competing, unstable hydrodynamic forces acting on the liquid jet as it exits the nozzle. The nozzle geometry and up-stream injection conditions affect the characteristics of flow inside the nozzle, such as turbulence and cavitation bubbles. A set of calculations of the internal flow in a pintle type nozzle were performed using a two dimensional flow simulation under different nozzle geometry and upstream flow conditions. The calculation showed that the turbulent intensity and discharge coefficient are related to needle leading angle(.alpha.) and needle lift.edle lift.

A Study on the Numerical Analysis of Internal Flow in a Cone Type Valve (Cone Type 밸브 내부유동 수치해석에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.199-207
    • /
    • 2020
  • These days, many different types of valves are developed in the industrial area according to their use purpose. Multiple kinds of valves are installed to control a flow and pressure of the pipe conveying fluid. Valves serve as critical roles in land plants such as power plants. The performance of equipment varies depending on valve characteristics. In this study, the internal flow analysis on Cone-type valve is conducted to analyze flow field and secure a value of the flow coefficient Cv. According to the internal flow analysis, when the flow distribution of the middle cross-section of valve was open 100%, flow field was relatively and smoothly taken out. If it was open 50%, flow recirculation region increased and a little complex flow field occurred. Unlike ball valve or butterfly valve, this valve had flow recirculation in its outlet depending on a valve opening amount. Therefore, it was found that there was no flow recirculation in the outlet of Cone-type valve.

Numerical Analysis for the Effect of Flow Skirt Geometry on the Flow Distribution in the Scaledown APR+ (유동 덮개 형상이 축소 APR+ 내부 유동분포에 미치는 영향에 대한 수치해석)

  • Lee, Gong Hee;Bang, Young Seok;Woo, Sweng Woong;Kim, Do Hyeong;Kang, Min Ku
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.5
    • /
    • pp.269-278
    • /
    • 2013
  • In this study, in order to examine the applicability of computational fluid dynamics with the porous model to the analysis of APR+ (Advanced Power Reactor Plus) internal flow, simulation was conducted with the commercial multi-purpose computational fluid dynamics software, ANSYS CFX V.14. In addition, among the various reactor internals, the effect of flow skirt geometry on reactor internal flow was investigated. It was concluded that the porous model for some reactor internal structures could adequately predict the hydraulic characteristics inside the reactor in a qualitative manner. If sufficient computation resource is available, the predicted core inlet flow distribution is expected to be more accurate, by considering the real geometry of the internal structures, especially located in the upstream of the core inlet. Finally, depending on the shape of the flow skirt, the flow distribution was somewhat different locally. The standard deviation of the mass flow rate (${\sigma}$) for the original shape of flow skirt was smaller, than that for the modified shape of flow skirt. This means that the original shape of the flow skirt may give a more uniform distribution of mass flow rate at the core inlet plane, which may be more desirable for the core cooling.

Influence of Blade Outlet Angle and Blade Thickness on Performance and Internal Flow Conditions of Mini Centrifugal Pump

  • Shigemitsu, Toru;Fukutomi, Junichiro;Kaji, Kensuke
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.3
    • /
    • pp.317-323
    • /
    • 2011
  • Mini centrifugal pumps having a diameter smaller than 100mm are employed in many fields; automobile radiator pump, ventricular assist pump, cooling pump for electric devices and so on. Further, the needs for mini centrifugal pumps would become larger with the increase of the application of it for electrical machines. It is desirable that the mini centrifugal pump design be as simple as possible as precise manufacturing is required. But the design method for the mini centrifugal pump is not established because the internal flow condition for these small-sized fluid machines is not clarified and conventional theory is not suitable for small-sized pumps. Therefore, we started research on the mini centrifugal pump for the purpose of development of high performance mini centrifugal pumps with simple structure. Three types of rotors with different outlet angles are prepared for an experiment. The performance tests are conducted with these rotors in order to investigate the effect of the outlet angle on performance and internal flow condition of mini centrifugal pumps. In addition to that, the blade thickness is changed because blockage effect in the mini centrifugal pump becomes relatively larger than that of conventional pumps. On the other hand, a three dimensional steady numerical flow analysis is conducted with the commercial code (ANSYS-Fluent) to investigate the internal flow condition. It is clarified from the experimental results that head of the mini centrifugal pump increases according to the increase of the blade outlet angle and the decrease of the blade thickness. In the present paper, the performance of the mini centrifugal pump is shown and the internal flow condition is clarified with the results of the experiment and the numerical flow analysis. Furthermore, the effects of the blade outlet angle and the blade thickness on the performance are investigated and the internal flow of each type of rotor is clarified by the numerical analysis results.