• 제목/요약/키워드: Interruption

검색결과 1,042건 처리시간 0.029초

Assessment of Interruption Costs for Public Customers

  • Choi Sang-Bong
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.186-192
    • /
    • 2005
  • As the power industry moves towards open competition, there has been a call for methodology to evaluate power system reliability by using customer interruption costs. This paper presents an evaluation of the interruption costs for public customers in Korea using customer survey methodology. When various research results are examined, the evaluation of direct interruption costs becomes much more simplified. Especially, in the case of public customers, it is known that the evaluation of direct interruption costs is more useful. Accordingly, this paper selected the customer survey method to evaluate the interruption costs for public customers in Korea considering interruption and customer characteristics.

배전기자재별 고장확률을 고려한 배편계통 수용가 정전비용 산출 기법 (Evaluation Methodology of System Interruption Cost Taking into Consideration Failure Rate of Distribution Facilities)

  • 최상봉;김대경;정성환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권5호
    • /
    • pp.232-237
    • /
    • 2002
  • It is increased for methodology to evaluate distribution power system interruption cost in power supply zones under competitive electricity market. This paper presents algorithms to evaluate system interruption cost in distribution power supply zones taking into consideration failure rate of distribution facilities and composite customer interruption cost. In this paper, it is introduced for weighting factor for each customer failure duration and failure rate of distribution facilities to evaluate reasonable system interruption cost in distribution power supply area. Also, this Paper estimates evaluation results of system interruption cost using a sample model system. Finally, evaluation results of system interruption cost based on failure rate of distribution facilities and composite customer interruption cost are shown in detail.

Evaluation of the Interruption Cost of Distribution Power Systems Considering the Failure Source and the Composite Customer Interruption Cost

  • Park, Sang-Bong;Nam, Kee-Young;Kim, Dae-Kyeong;Jeong, Seong-Hwan
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권3호
    • /
    • pp.124-129
    • /
    • 2003
  • As the power industry moves towards open competition, there has been a call for methodology to evaluate power system reliability by using composite interruption cost. This paper presents algorithms to evaluate the interruption cost of distribution power systems by taking into consideration the failure source and the composite customer interruption cost. From the consumer's standpoint, the composite customer interruption cost is considered as the most valuable index to estimate the reliability of a power distribution system. This paper presents new algorithms that take into account the load by customer type and failure probability by distribution facilities while calculating the amount of unserved energy by customer type. Finally, evaluation results of unserved energy and system interruption cost based on composite customer interruption cost are shown in detail.

주택용 수용가 정전비용 평가 (Assessment of Interruption Costs for Residential Customers)

  • 최상봉;남기영;김대경;정성환;류희석;이재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.196-198
    • /
    • 2003
  • The impacts of electric service interruption to customers depend on customer and interruption characteristics. Customer characteristics include demographic aspects(residential type, and number of household members) and power supply types whereas interruption characteristics include frequency, duration, time, and day of interruption. Accordingly evaluation of these customer interruption costs is very complicated and subjective. For residential customers, customer survey method seems most appropriate because interruption impact to residential customers is intangible. In other words, the value of housework or lost leisure due to interruption is individual. Accordingly, this paper selected the customer survey method to assess the interruption costs for residential customers.

  • PDF

주택용 수용가의 정전비용 평가 연구 (Assessment of Interruption Costs for Residential Customers)

  • 박충열;최상봉;허창수
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.131-137
    • /
    • 2004
  • 전력서비스 중단이 전력소비자에 끼치는 충격은 소비자와 정전 특성에 달려있다 소비자 특성은 인구통계학적인 측면(주거형태와 가족구성원 수)과 전력공급 형태를 포함하는 반면에 정전특성은 발생 빈도, 기간, 시간과 요일을 포함한다. 따라서 이러한 소비자 정전비용의 평가는 상당히 복잡하고 주관적이다. 주거용 소비자들의 경우, 주거용 소비자에 대한 정전의 충격이 가시적이지 않기 때문에 소비자 조사 방법이 가장 적합할 것으로 보인다. 달리 말하면, 가사일과 정전으로 인해 여가의 가치가 각자 다르기 때문이다. 따라서 본 논문에서는 주택 수용가에 대한 정전 비용을 평가하기 위한 방법으로서 수용가 설문조사 방법을 선택하였다.

DC 그리드 안정성 향상을 위해 변압기형 초전도 한류기가 적용된 직류 차단 기술에 관한 연구 (A Study on DC Interruption Technology using a Transformer Type Superconducting Fault Current Limiter to Improve DC Grid Stability)

  • 황선호;최혜원;정인성;최효상
    • 전기학회논문지
    • /
    • 제67권4호
    • /
    • pp.595-599
    • /
    • 2018
  • Interruption system with the transformer type superconducting fault current limiter(TSFCL) is proposed in this paper. The interruption system with a TSFCL is a technology that it maximizes the interruption function of a mechanical DC circuit breaker using a transformer and a superconducting fault current limiter. By a TSFCL, the system limits the fault current till the breakable current range in the fault state. Therefore, the fault current could be cut off by a mechanical DC circuit breaker. The Interruption system with a TSFCL were designed using PSCAD/EMTDC. In addition, the Interruption system with a TSFCL was applied to the DC test circuit to analyze characteristics of a current-limiting and a interruption operation. The simulation results showed that the Interruption system with a TSFCL interrupted the fault current in a stable when a fault occurred. Also, The current-limiting rate of the Interruption system with a TSFCL was approximately 69.55%, and the interruption time was less than 8 ms.

An Efficient Interruption Handling for 3D Games based on Android Platform

  • Viet, Doan Quang;Choi, Chang Yeol
    • International Journal of Contents
    • /
    • 제8권4호
    • /
    • pp.42-49
    • /
    • 2012
  • Recently the unprecedented progress of Android platform and Google Play has brought more opportunities for individual mobile game developers. When playing an Android 3D game, users can accidentally hit HOME Key or BACK Key or receive an incoming message. Subsequently, another screen will appear on top and make the game application lose focus, or the operating system pause that game. These interruption events may also lead to the loss of game information or the game runs out of user control if that game cannot catch interruption events itself and resume at the exact time. As same as other mobile platforms, Android platform also provides Activity Lifecycle methods to help the game application control interruption problems. However, these methods are not adequate to solve all the interruption events. By implementing ANDCube game, we examine most of the possible interruption cases and propose some solutions to help Android game developers avoid some common interruption cases. Concurrently, we show the ways how a game application can catch all unavoidable interruption events and effectively resume from interruption to obtain a high quality game.

Power Interruption Costs to Commercial Customers of Electricity in Korea

  • Kim, Dong-Sub;Kim, Kil-Sin
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1495-1500
    • /
    • 2014
  • This paper presents the result of the estimation of the power interruption costs of Korean commercial customers. Commercial customers are usually located in urban areas and considered very important because a power interruption on them can expand to additional damage to related users. Their power interruption costs were calculated through a survey with the process of data selection. Also, the power interruption cost for each customer's business type was calculated and compared with that of foreign cases.

응급실 간호사의 업무중단과 업무중단으로 인한 업무상 문제 및 소진과의 관계 (Relationship among Task Interruption and Task Performance and Burn-out in Emergency Room Nurses)

  • 유은정;이은남
    • 중환자간호학회지
    • /
    • 제6권1호
    • /
    • pp.34-43
    • /
    • 2013
  • Purpose: This study was conducted to examine the relationship among task interruption, task performance, and burn-out in nurses working at emergency room. Methods: The subjects of this study were 225 working at emergency rooms of 19 hospitals. Data was collected by using the structured questionnaire, including frequency of task interruption. problems in task performance due to interruption, and burn-out. Results: The average scores of task interruption were 2.06 due to communication, 1.49 due to treatment and record, and 1.39 due to other services (range 1-4). Frequency of task interruption was significantly correlated with task performance and burn-out. Conclusion: Emergency room nurses experienced some task interruption. The task interruption can influence upon task performance and burn-out of emergency room nurse.

  • PDF

Evaluation of the Reliability of Distribution Power Systems Considering Composite Customer Interruption Cost

  • Choi Sang-Bong;Nam Kee-Young;Kim Dae-Kyeong;Jeong Seong-Hwan;Lee Jae-Duk;Ryoo Hee-Suk
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권3호
    • /
    • pp.286-292
    • /
    • 2005
  • As the power industry moves towards open competition, there has been a call for methodology to evaluate power system reliability by using composite interruption cost. This paper presents algorithms to evaluate the interruption cost of distribution power systems by taking into consideration the failure source and the composite customer interruption cost. From the consumer's standpoint, the composite customer interruption cost is considered as the most valuable index to estimate the reliability of a power distribution system. This paper presents new algorithms that consider the load by customer type and failure probability by distribution facilities while calculating the amount of unserved energy by customer type. Finally, evaluation results of unserved energy and system interruption cost based on composite customer interruption cost are shown in detail.