• Title/Summary/Keyword: Iomeprol

Search Result 4, Processing Time 0.02 seconds

Comparative Analysis of Death-Related Iodide Contrast Media due to Adverse Reactions of Contrast Media in Computed Tomography (컴퓨터단층촬영의 요오드화 조영제 부작용으로 인한 사망 관련 조영제 비교 분석)

  • Yu, Seong-Min;Han, Dong-Kyoon;Hong, Joo-Wan
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.47-52
    • /
    • 2021
  • The incidence of adverse reactions to iodide contrast media was found to have increased owing to their increased use in computed tomography, but the exact reasons were unknown. Based on reported iodide contrast media adverse reactions data, it is recommended to the components of iodide contrast media before use to minimize adverse reactions. It was found that the use of iopromide and iomeprol in iodide contrast media resulted in a higher incidences of death and threat of life resulting from adverse reactions than other ingredients. Patients who are administered iodide contrast media containing iopromide and iomeprol during the computed tomography test should be carefully examined by the relevant medical professional, as the significance of gender and age varies from component to component. As multiple iodide contrast agents are available, the use of an appropriate iodide contrast media will reduce the incidence of iodide contrast media adverse reactions.

Chemical Structure Analysis of Non-ionic Monomer Contrast Agents Using 1H-NMR Spectroscopy (1H-NMR Spectroscopy를 이용한 Non-ionic Monomer 조영제의 화학적 구조 분석)

  • Han, Beom-Hee
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.335-342
    • /
    • 2021
  • Studies on the side effects of contrast agents are being discussed based on various cases, but studies analyzing the chemical structure of the underlying contrast agents are difficult to understand as the manufacturers have not disclosed them. Therefore, in this study, the chemical structure of the contrast medium was analyzed using 1H-NMR spectrometer for Omnipaque contrast medium prepared from Iohexol, which is a nonionic iodide contrast medium, Xenetix contrast medium from Iobitridol, and Iomeron contrast medium from Iomeprol. As a result, it was found that the Omnipaque contrast medium of Iohexol had 6 carboxyl groups, 3 carbonyl groups, 4 amine groups, 1 methyl group, and 2 cyano groups. It was found that the Xenetix contrast medium of the iobitridol formulation had 6 carboxyl groups, 3 carbonyl groups, 2 amine groups, and 4 cyano groups. It was found that the Iomeron contrast agent of the Iomeprol formulation had 5 carboxyl groups, 3 carbonyl groups, 4 amine groups, 1 methyl group, and 2 cyano groups. As shown in this study, the chemical structure of the non-ionic monomer contrast agent increases its affinity with water by binding a number of hydroxyl groups (OH) to the carboxyl group. It is necessary to accurately identify each of these factors and analyze the physical and chemical changes of the contrast medium according to various environmental factors.

Effects of CT Contrast Medium on the Relaxation Rate of MR Contrast Medium (CT 조영제가 MR 조영제의 이완율에 미치는 영향)

  • Kwon, Soon-Yong;Kang, Chung-Hwan;Jeong, Hyeon Keum;Park, Jin Seo;Kim, Seong-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.103-107
    • /
    • 2018
  • In MR, the iodine CT contrast medium reduces the T1 and T2 relaxation times of the substance, resulting in a change in signal intensity. This study aimed to measure the relaxation rate of MR contrast medium with or without diluting CT contrast medium and analyzed the effect of CT contrast medium. Undiluted Gadoteridol solution was diluted with saline to prepare MR contrast medium phantoms with various levels of Gadoteridol concentrations. Moreover, undiluted Iomeprol was mixed with the prepared MR contrast medium phantoms at 1:1 ratio to make MR contrast medium phantoms with containing CT contrast medium for the experiment. T1 and T2 mappings were conducted to quantitatively evaluate the relaxation time and relaxation rate of these phantoms. The results showed that the T1 and T2 relaxation time and relaxation rate of MR contrast medium diluted with CT contrast medium were significantly (p<0.05) shorter than those of MR contrast medium not diluted with CT contrast medium. The results of this study imply that, when MR contrast medium shall be used after injecting CT contrast medium, CT contrast medium should be discharged enough. Moreover, it would be desirable to conduct CT test after taking MRI test in order to reduce the effects of CT contrast medium on MR contrast medium.

Signal Change of Iodinated Contrast Agents in MR Imaging (요오드화 조영제가 MR영상에 미치는 신호 변화)

  • Jeong, HK;Kim, Seongho;Kang, Chunghwan;Lee, Suho;Yi, Yun;Kim, Mingi;Kim, Hochul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.131-138
    • /
    • 2016
  • In this study, we tried to analyze the influence of ICM(Iodinated Contrast Media) in MR imaging compare to GBCA(Gadolinium Based Contrast Agent), and as this result we discussed whether resonable or not the protocol which is MRI scan after enhanced CT scan without proper time interval in clinical field. For this research, we assembled two phantoms. which one was iodine and another one was gadolinium. We did test two phantoms in conventional MRI scan which is T1, T2, T2 FLAIR and 3D angio. After that, quantitative analysis was progressed. The results of study were as follow : SSI(Saline's Signal Intensity) was shown as each sequences 175, 1231, 333, 37 [a.u] at iodine. and 1297, 123, 757, 232 [a.u] was recorded at gadolinium. BDEPS(the Biggest Difference of EPS) was shown as each sequences 1297, 123, 757, 232 [a.u] at iodine and 793, 6, 1495, 365 [a.u] was recorded at gadolinium. At this time, EPS(Enhancement Percentage to Saline) was shown 641.1, -90.0, 127.3, 527% at iodine and 685.1, 99.4, 365.7, 1077.4% was recorded at gadolinium. BP(BDEPS's point) was shown 900, 900, 477, 900 mmol at iodine and 4, 0.2, 0.2, 40 mmol was recorded at gadolinium. CPSS(Change Point of SI to SSI) was shown 63, 423, 63, 29 mmol at iodine and each [50, 30], [4, 0.2], [4, 1], 0.2 mmol was recorded at gadolinium. According to this research, we could not only discover the fact that was iodine could effect on MR signal, but also the pattern is different as various sequences compare to gadolinium. Therefore, we expect useful diagnostic MR image in clinical field with this quantitative data for deciding protocol regarding MRI and CT scan order.