• Title/Summary/Keyword: Islanding

Search Result 189, Processing Time 0.024 seconds

A Study on the Islanding Detection for Grid Connected Photovoltaic System (계통연계형 태양광발전시스템을 위한 단독운전 검출에 관한 연구)

  • Lee Gi-Je;Kim Min;Lee Jin-Seop;Yu Gwon-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.555-558
    • /
    • 2002
  • The general ways of the anti-islanding can be classified into the active method and passive method. The passive method which use only the voltage information when power failure occurs has much possibility of the wrong detection. And the active method detects the change of the voltage frequency as instantaneously changing the frequency of the inverter output current. Therefore, in this paper, the method to inject arbitrary order harmonics into controlled current is proposed. In this method islanding can be detected by measuring the amount of load voltage of injected harmonics order. And as a current control method predictive control method is used, which make actual current accurately to track reference current by Instantaneously computing converter output voltage and has fast response in transient state. This parer proposed method was verified by simulation.

  • PDF

A Control and Protection Model for the Distributed Generation and Energy Storage Systems in Microgrids

  • Ballal, Makarand Sudhakar;Bhadane, Kishor V.;Moharil, Ravindra M.;Suryawanshi, Hiralal M.
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.748-759
    • /
    • 2016
  • The microgrid concept is a promising approach for injecting clean, renewable, and reliable electricity into power systems. It can operate in both the grid-connected and the islanding mode. This paper addresses the two main challenges associated with the operation of a microgrid i.e. control and protection. A control strategy for inverter based distributed generation (DG) and an energy storage system (ESS) are proposed to control both the voltage and frequency during islanding operation. The protection scheme is proposed to protect the lines, DG and ESS. Further, the control scheme and the protection scheme are coordinated to avoid nuisance tripping of the DG, ESS and loads. The feasibility of the proposed method is verified by simulation and experimental results.

Novel Anti-islanding method using phase shift with a periodic function (주기적 위상 변동 기법을 이용한 새로운 단독운전 검출 기법)

  • Jung, Young-Seok;Choi, Jae-Ho;So, Jung-Hoon;Yu, Byung-Guy;Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1153-1154
    • /
    • 2006
  • This paper proposes the optimal design method based on NDZ analysis to secure the islanding defection ability and to maintain the stability and power quality when the grid is connected. A PSiM-based model and analysis of the system is presented, specialty aimed at improving the effectiveness of phase shift anti-islanding method with frequency feedback, which causes the inverter current to be generated slightly lower or higher in frequency than the frequency of the terminal voltage. The proposed method can cause frequency jump with leading and lagging phase of output current in two line cycles. As a result, the proposed algorithm is more sensitive and reliable than the conventional phase shift method. Experimental results, on a 3 kW inverter connected to 220 V, 60 Hz utility, are discussed.

  • PDF

Islanding Detection Technique using Wavelet Energy in Grid-Connected PV System (웨이블렛 에너지를 이용한 태양광 발전시스템의 단독운전 검출 기법)

  • Park, Hae-Chan;Kim, Il-Song
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.5
    • /
    • pp.471-478
    • /
    • 2015
  • The new islanding detection method using wavelet energy is proposed in this paper. The proposed method is based on the autocorrelation of the wavelet energies, which is obtained from the high-frequency components of the grid voltage. It has the enhanced detection capabilities in the UV/OV/UF/OF region, which the conventional passive methods cannot obtain. The mathematical theories on the wavelet are presented, and the performance effectiveness is proved by the experimental results.

Micro-Grids Reliability Enhancement Under Different Penetration Levels of Hybrid DG Units

  • Essam, M.;Atwa, Y.M.;El-Saadany, Ehab F.;Conti, Stefania;Rizzo, Santi Agatino
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1407-1418
    • /
    • 2018
  • Novel mechanism of customized adequacy formulation is proposed in order to enhance micro grids system reliability. The mechanism accounts for 2-levles of load curtailment, and is mainly based on probabilistic load profile and hybrid Distributed Generation (DG) units modeling. The two load curtailments are needed in order to ensure adequate technical constraints at steady state condition during islanding mode of operation. The effectiveness of the proposed formulation has been verified using system independent analytical expressions for the evaluation of both reliability and Expected Energy Not Served (EENS) indices. The evaluation has examined the impact of different penetration levels of Hybrid DG Units in case study islands. Results show the enhancement of the overall distribution system reliability and the recommended conditions for successful islanding mode of operation.

The Operating characteristics of Community Energy System(CES) with Grid connection and isolation (지역 에너지 시스템의 계통 연계 및 독립 운전 특성에 관한 연구)

  • Park, Y.U.;Kim, K.H.;Jang, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.258-260
    • /
    • 2004
  • This paper analyse a operating characteristics when the Community Energy System (CES) is operated islanding mode. In the near future, CES might be one of major energy supply structures. The basic concept of CES is that it supplies electrical and thermal energy to the local customer loads through the islanded power network separated from the grid. The CES must be supplying local load with stable energy on the islanding mode, analysing necessary to thoroughly the operation feature. In order to show them, in this paper, we model the CES with 2.34 MVA DG and simulate the operating feature on the islanding mode of CES. The simulation results show that, in order to stability operate, the CES need the efficient load management and generation control schemes during the transition periods.

  • PDF

Indirect Current Control of Utility Interactive Inverter for Seamless Transfer (연속적인 운전모드의 전환을 위한 계통연계형 인버터의 간접 전류 제어기법)

  • Yu, Tae-Sik;Bae, Young-Sang;Kim, Hyo-Sung;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.72-78
    • /
    • 2006
  • Distributed generation (DG) systems go to intentional islanding operation to back up private emergency loads when the main grid is out of electric power. Conventional utility interactive inverters normally operated in current control mode in DG system must change their operation mode into voltage control mode to ensure stable voltage source to the emergency loads when intentional islanding operation occurs. During the transfer between current control mode and voltage control mode, serious transient problem may occur on the output terminal voltage of the utility interactive inverter. This paper proposes reasonal inverter topology and its control algorithm for seamless transfer of DG systems in intentional islanding operation. Filter design guide line and data for a LCL filter that is appropriate for the proposed control algorithm are also presented by the authors.

Wireless Sensor Network based Remote Power Monitoring System for Anti Islanding application in Smart-Grid (스마트 그리드 내 독립전원의 단독운전 방지를 위한 무선 센서 네트워크 기반의 원격 전력 감시 시스템)

  • Kim, Kee-Min;Lee, Kyung-Jung;Moon, Chan-Woo;Ahn, Hyun-Sik;Jeong, Gu-Min
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.57-62
    • /
    • 2010
  • Renewable energy and smart grid become the focus of attention of industry. The smart grid is an intelligent system which maximizes the efficiency of energy and it needs to monitor the amount of power generation and power consumption continuously. Remote Monitoring System(RMS) is very useful for monitoring the power generation and consumption, but mostly they are implemented on the wire communication. In this paper, we propose a wireless sensor network based remote power monitoring system. And as an application, a new anti-islanding method with the proposed RMS is presented. An experimental micro grid system is implemented to verify the proposed RMS and anti-islanding method.

Characteristics Analysis of RPV and AFD for Anti-Islanding in Active Method (단독운전방지를 위한 능동 방식 중 AFD 및 RPV에 대한 특성해석)

  • Choe, Gyu-Ha;D, Bayasgalan;Lee, Young-Jin;Han, Dong-Ha;Jeong, Byong-Hwan;Kim, Hong-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.160-167
    • /
    • 2009
  • To detect islanding mode when the grid is being tripped is a major safety issue in the Utility Interactive Photo Voltaic (UIPV) system. In this paper, analytical design method is suggested for AFD & RPV method under IEEE 929-2000 recommended islanding test condition. We have discussed that there is a same point. we injected reactive component of the current by AFD & RPV methods, but the current reference generated is other waveform. Possible if amount of reactive components in this methods are same each method, there is happened same rates frequency variation. To verify the validity of the analytical comparison, this paper presents simulation and experimental results from single phase, 3[kW] inverter for the transformerless UIPV system.

Development of a Smart Grid Monitoring System with Anti-Islanding Function for Electric Vehicle Charging (안티아일랜딩 기능을 적용한 전기자동차 충전계통 연계 스마트그리드 모니터링 시스템 개발)

  • Ro, Sunny;Shin, Bum-Sik;Lee, Kyung-Jung;Ki, Young-Hun;Ahn, Hyun-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.31-37
    • /
    • 2012
  • In this paper, we present a smart grid monitoring system connected with electric vehicle charging system using anti-islanding method. Electric vehicles can be charged through remote control of smart grid monitoring system and the charging process may be more stable and more efficient by wireless communication between the Local Area Module and End Modules. It is illustrated by some experiments that electric vehicle charging process may not be interrupted without any serious fault even though the islanding phenomena occurred in the grid if the presented monitoring system was applied to the smart grid system.