• Title/Summary/Keyword: Islanding

Search Result 189, Processing Time 0.03 seconds

Flap necrosis after palatoplasty in irradiated patient and its reconstruction with tunnelized-facial artery myomucosal island flap

  • Jeong, Hye-In;Cho, Hye-Min;Park, Jongyeol;Cha, Yong Hoon;Kim, Hyung Jun;Nam, Woong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.24.1-24.6
    • /
    • 2017
  • Background: Tunneled transposition of the facial artery myomucosal (FAMM) island flap on the lingual side of the mandible has been reported for intraoral as well as oropharyngeal reconstruction. This modified technique overcomes the limitations of short range and dentition and further confirms the flexibility of the flap. This paper presents a case of reconstructing secondary soft palatal defect due to flap necrosis following two-flap palatoplasty in irradiated patient with lingually transposed facial artery myomucosal island flap. Case presentation: The authors successfully reconstructed secondary soft palatal defect due to flap necrosis following two-flap palatoplasty in an irradiated 59-year-old female patient with tunnelized-facial artery myomucosal island flap (t-FAMMIF). Conclusions: Islanding and tunneling modification extends the versatility of the FAMM flap in the reconstruction of soft palatal defects post tumor excision and even after radiation, giving a great range of rotation and eliminating the need for revision in a second stage procedure. The authors thus highly recommend this versatile flap for the reconstruction of small and medium-sized oral defects.

Characteristic Analysis and Implementation of 30kW Portable Test Equipment for Performance Evaluation in Energy Storage System (30kW급 ESS용 이동형 성능평가 시험장치의 구현 및 특성분석)

  • Park, Jea-Bum;Kim, Mi-Sung;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.715-723
    • /
    • 2018
  • The energy storage system consists of batteries, power conditioning system and energy management system. If ESS is installed and operated in the field, SAT(Site Acceptance Test) of ESS is being essentially required for the safety and performance of ESS. Furthermore, in order to more accurately and reliably validate the performance of the ESS in advanced countries, it has been required to perform not only performance testing by H/W equipments but also performance verification by S/W tool. Therefore, this paper proposes the modeling of portable test equipment in order to evaluate the performance and reliability of ESS by using the PSCAD/EMTDC S/W. And also, the prototype of 30[kW] scaled portable test equipments is implemented based on the S/W modeling. From the results of various simulations and testings such as power quality, LVRT and anti-islanding tests, it is confirmed that 30[kW] scaled portable test equipment is useful for SAT of ESS, because the simulation results of PSCAD/EMTDC are identical to them of 30[kW] test equipment at the same test conditions.

Design and Control Method for Critical Load Supply Equipment using MCFC Electricity Generation Systems (대용량 MCFC 발전시스템을 이용한 비상부하 전력 공급 장치 설계 및 제어방법)

  • Kim, Dong-Hee;Kim, Jong-Soo;Choe, Gyu-Yeong;Lee, Byoung-Kuk;Kawk, Cheol-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.20-29
    • /
    • 2011
  • This paper proposes critical load following back-up system using MCFC stack. This system enables MCFC generation system to supply power to critical load without UPS and to generate rated power under grid fault state. This back-up system includes 'Load Leveler' that is connected with 3-phase inverter and is controlled by additional algorithm that includes critical load following. The proposed system and algorithm are verified by computer simulation based on 5kW system.

Hybrid Control and Protection Scheme for Inverter Dominated Microgrids

  • Xu, Xiaotong;Wen, Huiqing;Jiang, Lin;Hu, Yihua
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.744-755
    • /
    • 2017
  • With the high penetration of various sustainable energy sources, the control and protection of Microgrids has become a challenging problem considering the inherent current limitation feature of inverter-based Distributed Generators (DGs) and the bidirectional power flow in Microgrids. In this paper, a hybrid control and protection scheme is proposed, which combines the traditional inverse-time overcurrent protection with the biased differential protection for different feeders with different kinds of loads. It naturally accommodates various control strategies such as P-Q control and V-f control. The parameter settings of the protection scheme are analyzed and calculated through a fast Fourier transform algorithm, and the stability of the control strategy is discussed by building a small signal model in MATLAB. Different operation modes such as the grid-connected mode, the islanding mode, and the transitions between these two modes are ensured. A Microgrid model is established in PSCAD and the analysis results show that a Microgrid system can be effectively protected against different faults such as the single phase to ground and the three phase faults in both the grid-connected and islanded operation modes.

Strategy for the Seamless Mode Transfer of an Inverter in a Master-Slave Control Independent Microgrid

  • Wang, Yi;Jiang, Hanhong;Xing, Pengxiang
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.251-265
    • /
    • 2018
  • To enable a master-slave control independent microgrid system (MSCIMGS) to supply electricity continuously, the microgrid inverter should perform mode transfer between grid-connected and islanding operations. Transient oscillations should be reduced during transfer to effectively conduct a seamless mode transfer. This study uses a typical MSCIMGS as an example and improves the mode transfer strategy in three aspects: (1) adopts a status-tracking algorithm to improve the switching strategy of the outer loop, (2) uses the voltage magnitude and phase pre-synchronization algorithm to reduce transient shock at the time of grid connection, and (3) applies the hybrid-sensitivity $H_{\infty}$ robust controller instead of the current inner loop to improve the robustness of the controller. Simulations and experiments show that the proposed strategy is more practical than the traditional proportional-derivative control mode transfer and effective in reducing voltage and current oscillations during the transfer period.

Simulation of Anti-Islanding Algorithms regarding IEEE Std. 1547.1 for Grid-Connected Photovoltaic Inverters (계통연계형 태양광 인버터의 IEEE Std. 1547.1 에 따른 단독운전 검출 알고리즘의 시뮬레이션)

  • Ko, Moon-Ju;Choy, Ick;Choi, Ju-Yeop;Lee, Ki-Ok;Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.323-325
    • /
    • 2005
  • 본 논문에서는 계통연계형 태양광 발전 시스템에서의 단독운전 검출 시뮬레이션 과정을 설명한다. 전기적 시스템의 단독운전은 계통이 끊어진 상태에서 분산 전원이 계속 동작하여 지역 부하로 전력이 공급될 때 나타나는 현상이다. 이러한 현상은 계통 보수 작업자의 안전을 위협하며, 다른 전기적 장비에 악영향을 미칠 수 있다. 단독운전 검출 기능은 계통과 연계된 분산전원과 같은 기능을 가진 태양광 발전 시스템에 사용되는 인버터에서는 주요한 요구사항이다. IEEE Std. 1547.1 "IEEE Standard Conformance Test Procedures for Equipment Interconnecting Distribuyed Resources with Electric Power Systems" 는 단독운전 검출을 필요로 하는 시스템의 테스트 요구사항을 정하고 있다. 본 논문은 단독운전 검출 알고리즘과 IEEE Std. 1547.1의 내용에 준한 인버터 시뮬레이션 테스트의 예를 보여준다. PSIM을 이용한 시뮬레이션 과정과 결과 파형의 분석을 토대로 계통연계형 인버터의 시뮬레이션 절차와 방법에 대해 알아본다.

  • PDF

Application of Conservation Voltage Reduction using Automatic Voltage Regulator of Linear Voltage Control in Campus Microgrid with Power Consumption Reduction (에너지 절감을 고려한 캠퍼스 마이크로그리드에서 선형 전압제어 방식의 AVR을 이용한 CVR의 적용)

  • Lim, Il-Hyung;Lee, Myung-Hwan;Shin, Yong-Hark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1039-1046
    • /
    • 2017
  • Campus microgrid is designed and built by considering not only power generation but also power consumption management as connected microgrid type because the main goal of the campus microgrid is to save power consumption costs. There are many functions to achieve the goal and they are mainly to use generation-based functions such as islanding operation for peak management and for emergency events. In power distribution operation, Conservation Voltage Reduction (CVR) is applied in order to reduce power consumption. The CVR is defined as a function for load consumption reduction by voltage reduction in order to reduce peak demands and energy consumption. However, application of CVR to microgrid is difficult because the microgrid cannot control a tap of transformer in a substation and the microgrid normally is not designed with phase modifying equipment like a step-voltage-regulator which can control voltage in power distribution system operation. In addition, an impact of the CVR is depended on load characteristics such as a normal load, a rated power, and synchronous motors. Therefore, this paper proposes an application of CVR using linear voltage control based AVR in campus microgrid with power consumption reduction considering characteristics of load and component in the microgrid. The proposed system can be applied to each buildings by a configuration of power distribution cables; and the application results and CVR factor are presented in this paper.

Review for Applying Spent Fuel Pool Island (SFPI) during Decommissioning in Korea (원전해체시 독립된 사용후핵연료저장조 국내 적용 검토)

  • Baik, Jun-ki;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.2
    • /
    • pp.163-169
    • /
    • 2015
  • In many nuclear power plant sites in Korea, high density storage racks were installed in the spent fuel pool to expand the spent fuel storage capacity. Nevertheless, the capability of the Hanbit nuclear site will be saturated by 2024. Also, 10 NPPs will reach their design life expiration date by 2029. In the case of the US, SFPI (Spent Fuel Pool Island) operated temporarily as a spent fuel storage option before spent nuclear fuels were transported to an interim storage facility or a final disposal facility. As a spent fuel storage option after shutdown during decommissioning, the SFPI concept can be expected to have the following effects: reduced occupational exposure, lower cost of operation, strengthened safety, and so on. This paper presents a case study associated with the regulations, operating experiences, and systems of SFPI in the US. In conclusion, the following steps are recommended for applying SFPI during decommissioning in Korea: confirmation of design change scope of SFPI and expected final cost, the submission of a decommissioning plan which is reflected in SFPI improvement plans, safety assessment using PSR, application of an operating license change for design change, regulatory body review and approval, design change, inspection by the regulatory body, education and commissioning for SFPI, SFPI operation and periodic inspection, and dismantling of SFPI.

Phase Transition and Formatio of $TiSi_2$ Codeposited on Atomicaily Clean Si(111) (초청정 Si기판에 동시 증착된 $TiSi_2$ 의 상전이 및 형성)

  • Gang, Eung-Yeol;Jo, Yun-Seong;Park, Jong-Wan;Jeon, Hyeong-Tak;Nemaniah, R.J.
    • Korean Journal of Materials Research
    • /
    • v.4 no.1
    • /
    • pp.107-112
    • /
    • 1994
  • The phase transition and the surface and interface morphologies of $TiSi_2$ formed on atomically clean Si substrates are investigated. 200$\AA$ Ti and 400$\AA$ Si films on Si(ll1) have been codeposited at elevated temperatures (400~$800^{\circ}C$) in ultrahigh vacuum. The phase transition of TiSiL is characterized with using XRD. The results distinguish the formation of the C49 and C54 crystalline titanium silicides. The surface and interface morphologies of titanium silicides have been examined with SEM and TEM. A relatively smootb surface is observed for the C49 phase while a rough surface and interface are observed for C54 phase. The islanding of the C54 phase becomes severe at high temperature ($800^{\circ}C$). Islands of TiSiL have been observed at temperatures above $700^{\circ}C$ but no islands are observed at temperatures below $600^{\circ}C$. For films deposited at $400^{\circ}C$ and 500%. weak XRD peaks corresponding to TiSi were observed and TEM micrographs exhibited small crystalline regions of titanium silicide at the interface.

  • PDF