• Title/Summary/Keyword: Jap Byoung

Search Result 4, Processing Time 0.019 seconds

A Study on the Meridians for treat the miscellaneous diseases in Jap ByoungPyeon(雜病篇) of the Young Chu(靈樞) (영추(靈樞).잡병편(雜病篇)의 잡병치료경락(雜病治療經絡)에 대한 연구(硏究))

  • Lee Moon-Og;Yuk Sang-Won
    • Korean Journal of Acupuncture
    • /
    • v.20 no.4
    • /
    • pp.99-119
    • /
    • 2003
  • Objectives : The Jap Byoung(雜病) of the Young Chu(靈樞), one of the classical book of oriental medicine contains symptoms and remedies for various diseases that can be seen on human body. But it is too difficult to understand the Jap Byoung(雜病), because it is written in old chinese and there are many printer's error and omissions or adds in this book. As a consequence of above reason, the writer of this article has researched to find out the exact meaning of that. Methods : So in this part we study a woodblock-printed book of successive generation and view of annotators, and add adding notes, adjustment, translation to exact comprehension of the original text. Results & conclusions : The principle ideas of the thesis can be summarized as follows: The Jap Byoung(雜病) is consist of five part. In chapter 1, we present symptoms occurred by the upstream current of Qi(氣逆) and their treatments by taking meridian flowing the body parts on which the symptoms occur. In chapter 2, we deal with symptoms such as ikgun(?乾), a pain of the knee(膝中痛), huby(喉痺), epistaxis(?血), lumbago(腰痛), anger(怒), a pain of the jaw(痛), a pain of the nape(項痛) and their remedies. In chapter 3, since abdominal inflation occurs when the Qi(氣) of the five viscera(五臟) is damaged or go upstream, I discussed that the treatment should be given by taking the meridian accordingly. In chapter 4, we deal with the remedy for heartache, and different meridians to be taken by symptom, and parts on which needle to be used, and detailed remedies. In chapter 5, we present other diseases, detailed body parts to be cured and remedies by referring symptoms for a pain of the jaw(痛), the upstream current of Qi(氣逆), hiccup, etc. Especially, we introduce a part of Doinbup(導引法) for wegurl(?厥) and remedies for hiccup such as inducing sneeze by stimulating nostrils, holding one's breath, etc.

  • PDF

Comparable efficacy of silk fibroin with the collagen membranes for guided bone regeneration in rat calvarial defects

  • Kim, Jwa-Young;Yang, Byoung-Eun;Ahn, Jin-Hee;Park, Sang O;Shim, Hye-Won
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.539-546
    • /
    • 2014
  • PURPOSE. Silk fibroin (SF) is a new degradable barrier membrane for guided bone regeneration (GBR) that can reduce the risk of pathogen transmission and the high costs associated with the use of collagen membranes. This study compared the efficacy of SF membranes on GBR with collagen membranes (Bio-$Gide^{(R)}$) using a rat calvarial defect model. MATERIALS AND METHODS. Thirty-six male Sprague Dawley rats with two 5 mm-sized circular defects in the calvarial bone were prepared (n=72). The study groups were divided into a control group (no membrane) and two experimental groups (SF membrane and Bio-$Gide^{(R)}$). Each group of 24 samples was subdivided at 2, 4, and 8 weeks after implantation. New bone formation was evaluated using microcomputerized tomography and histological examination. RESULTS. Bone regeneration was observed in the SF and Bio-$Gide^{(R)}$-treated groups to a greater extent than in the control group (mean volume of new bone was $5.49{\pm}1.48mm^3$ at 8 weeks). There were different patterns of bone regeneration between the SF membrane and the Bio-$Gide^{(R)}$ samples. However, the absolute volume of new bone in the SF membrane-treated group was not significantly different from that in the collagen membrane-treated group at 8 weeks ($8.75{\pm}0.80$ vs. $8.47{\pm}0.75mm^3$, respectively, P=.592). CONCLUSION. SF membranes successfully enhanced comparable volumes of bone regeneration in calvarial bone defects compared with collagen membranes. Considering the lower cost and lesser risk of infectious transmission from animal tissue, SF membranes are a viable alternative to collagen membranes for GBR.

Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures

  • Shim, Hye Won;Yang, Byoung-Eun
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.423-430
    • /
    • 2015
  • PURPOSE. To evaluate the cumulative survival rate (CSR) and mechanical complications of single-tooth $Ankylos^{(R)}$ implants. MATERIALS AND METHODS. This was a retrospective clinical study that analyzed 450 single $Ankylos^{(R)}$ implants installed in 275 patients between December 2005 and December 2012. The main outcomes were survival results CSR and implant failure) and mechanical complications (screw loosening, fracture, and cumulative fracture rate [CFR]). The main outcomes were analyzed according to age, sex, implant length or diameter, bone graft, arch, and position. RESULTS. The 8-year CSR was 96.9%. Thirteen (2.9%) implants failed because of early osseointegration failure in 3, marginal bone loss in 6, and abutment fracture in 4. Screw loosening occurred in 10 implants (2.2%), and 10 abutment fractures occurred. All abutment fractures were located in the neck, and concurrent screw fractures were observed. The CSR and rate of screw loosening did not differ significantly according to factors. The CFR was higher in middle-aged patients (5.3% vs 0.0% in younger and older patients); for teeth in a molar position (5.8% vs 0.0% for premolar or 1.1% for anterior position); and for larger-diameter implants (4.5% for 4.5 mm and 6.7% for 5.5 mm diameter vs 0.5% for 3.5 mm diameter) (all P<.05). CONCLUSION. The $Ankylos^{(R)}$ implant is suitable for single-tooth restoration in Koreans. However, relatively frequent abutment fractures (2.2%) were observed and some fractures resulted in implant failures. Middle-aged patients, the molar position, and a large implant diameter were associated with a high incidence of abutment fracture.

Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Su-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • PURPOSE. This study investigated the strain of implants using a chewing simulator with strain gauges in mandibular implant-supported fixed prostheses under various dynamic loads. MATERIALS AND METHODS. Three implant-supported 5-unit fixed prostheses were fabricated with three different occlusion types (Group I: Canine protected occlusion, Group II: Unilaterally balanced occlusion, Group III: Bilaterally balanced occlusion). Two strain gauges were attached to each implant abutment. The programmed dynamic loads (0 - 300 N) were applied using a chewing simulator (MTS 858 Mini Bionix II systems, MTS systems corp., Minn, USA) and the strains were monitored. The statistical analyses were performed using the paired t-test and the ANOVA. RESULTS. The mean strain values (MSV) for the working sides were 151.83 ${\mu}{\varepsilon}$, 176.23 ${\mu}{\varepsilon}$, and 131.07 ${\mu}{\varepsilon}$ for Group I, Group II, and Group III, respectively. There was a significant difference between Group II and Group III (P < .05). Also, the MSV for non-working side were 58.29 ${\mu}{\varepsilon}$, 72.64 ${\mu}{\varepsilon}$, and 98.93 ${\mu}{\varepsilon}$ for Group I, Group II, and Group III, respectively. One was significantly different from the others with a 95% confidence interval (P < .05). CONCLUSION. The MSV for the working side of Groups I and II were significantly different from that for the non-working side (Group I: t = 7.58, Group II: t = 6.25). The MSV for the working side of Group II showed significantly larger than that of Group III (P < .01). Lastly, the MSV for the non-working side of Group III showed significantly larger than those of Group I or Group II (P < .01).