• Title/Summary/Keyword: Jaw upper

Search Result 209, Processing Time 0.024 seconds

A Study of Simple Hinge Articulator Mounting Method (단순접번 교합기의 모형부착 방법에 관한 연구)

  • Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.95-102
    • /
    • 2003
  • The purpose of this study was to show occlusion on the simple hinge articulator optionally mounted. Modelling of upper-lower jaw and simple hinge articulator were developed. This modelling of upper-lower jaw inserting wax bite was mounted imaginary on the modelling of simple hinge articulator by use of the computer simulation. From changes of THA(transverse horizontal axis)-incisor distance, Balkwill angle and THA deviation, eight types were mounted respectively. After removal of wax bite, upper-lower jaw position changing were compared with centric jaw relation. The results were as follows: 1. The change of THA-incisor distance had influence on mostly a vertical shift of upper jaw. 2. The change of Balkwill angle had influence on mostly a horizontal shift of upper jaw. 3. Inferior type in the THA deviations was the least shift of upper jaw. The above results suggest that the simple hinge articulator optionally mounted effect a shift of upper jaw.

  • PDF

제1대구치교합거상으로 일어나는 상하악교두거상거리의 증가에 관한 계측

  • Lee, Myung-Chong
    • The Journal of the Korean dental association
    • /
    • v.12 no.9
    • /
    • pp.691-694
    • /
    • 1974
  • The trends of restoration on abrased teethis mostly based on gnathology or on practical experience. This study was performed on plaster models from 60 young men whose teeth and occlusion are clinically normal. A pair, upper and lower models, were mounted on HANAU articulator. Iron ball bearing 0.2mm 0.5mm 0.7mm and 1.0mm in diameter was attached on mesiobuccal cusp of upper first molar. [table I] Long ribbon shape of cold cure resin was inserted and jaw was closed gently so as not to move disturb original position of iron ball. The resin bite registration was measured minimun thickness from each lingual cusps of upper jaw and buccal cusps of lower jaw by means of Bowley gauge. The results were as follows (graph). 1) The distance from upper lingual cusps and lower buccal cusps: backward cusps showed smaller than standard cusp (upper mesio-buccal cusp) and forward cusps showed longer than standard. 2) The measurements from upper lingual cusps are not coincide with lower buccal cusps.

  • PDF

Radiographic Diagnosis of 'Rubber Jaw Syndrome' Secondary to Chronic Renal Failure Due to Ethylene Glycol Intoxication in a Dog (개에서 Ethylene glycol 중독에 의한 만성신부전증의 속발성 'Rubber jaw syndrome'의 방사선학적 진단례)

  • Choi, Ho-Jung;Lee, Young-Won;Wang, Ji-Hwan;Jung, In-Jo;Yeon, Seong-Chan;Lee, Hyo-Jong;Lee, Hee-Chun
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.260-263
    • /
    • 2007
  • A 9-month-old, intact female mixed dog was referred to Veterinary Medical Teaching Hospital of Gyeongsang National University with symmetrically enlarged and protruded upper jaw. The patient was diagnosed as acute renal failure due to ethylene glycol poisoning and was treated for 1 month in a local animal hospital. In spite of treatment, the patient proceeded to chronic renal failure. Also, the patient's upper jaw begun to enlarge continuously. To evaluate this upper jaw, radiographic examination was performed. Skull radiographs revealed thickening of maxilla, decreased bone opacity, cortical thinning, loss of lamina dura and periodontal space in the maxilla. Diagnosis of rubber jaw syndrome is based on clinicial signs, radiographic findings and laboratory evidence of chronic renal failure due to ethylene glycol poisoning.

FABRICATION OF SURGICAL SPLINT BY USING OF SURGICAL JAW RELATOR (Surgical Jaw Relator를 이용한 Surgical splint의 제작)

  • Yang, Sang-Duck
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.2
    • /
    • pp.188-195
    • /
    • 2005
  • After making the surgical treatment plan, the surgical movements are duplicated in the model surgery. During this procedure, reference points and lines are drawn on the base of the models over the dental arch, and sawcuts are made according to these marked osteotomy lines. This method requires more accuracy for better postsurgical results in that the surgical splint which enables the surgeon to position the jaws intraoperatively is made from the casts as repositioned by the model surgery, and finally it will define the postsurgical results. This technique, however, has been found to be inexact, especially when the jaws are moved in several dimensions simultaneously. To overcome this, different methods have been developed for an accurate repositioning of the jaws as planned. A new appliance, Surgical Jaw Relator, was devised by the author for the simple 3-dimensional relocation of the upper and lower models, resulting in the easy construction of the splints such as centric relation splint, intermediate and final splint. This article describes an introduction and a clinical application of this appliance.

Coordinative movement of articulators in bilabial stop /p/

  • Son, Minjung
    • Phonetics and Speech Sciences
    • /
    • v.10 no.4
    • /
    • pp.77-89
    • /
    • 2018
  • Speech articulators are coordinated for the purpose of segmental constriction in terms of a task. In particular, vertical jaw movements repeatedly contribute to consonantal as well as vocalic constriction. The current study explores vertical jaw movements in conjunction with bilabial constriction in bilabial stop /p/ in the context /a/-to-/a/. Revisiting kinematic data of /p/ collected using the electromagenetic midsagittal articulometer (EMMA) method from seven (four female and three male) speakers of Seoul Korean, we examined maximum vertical jaw position, its relative timing with respect to the upper and lower lips, and lip aperture minima. The results of those dependent variables are recapitulated in terms of linguistic (different word boundaries) and paralinguistic (different speech rates) factors as follows. Firstly, maximum jaw height was lower in the across-word boundary condition (across-word < within-word), but it did not differ as a function of different speech rates (comfortable = fast). Secondly, more reduction in the lip aperture (LA) gesture occurred in fast rate, while word-boundary effects were absent. Thirdly, jaw raising was still in progress after the lips' positional extrema were achieved in the within-word condition, while the former was completed before the latter in the across-word condition. Lastly, relative temporal lags between the jaw and the lips (UL and LL) were more synchronous in fast rate, compared to comfortable rate. When these results are considered together, it is possible to posit that speakers are not tolerant of lenition to the extent that it is potentially realized as a labial approximant in either word-boundary condition while jaw height still manifested lower jaw position in the across-word boundary condition. Early termination of vertical jaw maxima before vertical lower lip maxima across-word condition may be partly responsible for the spatial reduction of jaw raising movements. This may come about as a consequence of an excessive number of factors (e.g., upper lip height (UH), lower lip height (LH), jaw angle (JA)) for the representation of a vector with two degrees of freedom (x, y) engaged in a gesture-based task (e.g., lip aperture (LA)). In the task-dynamic application toolkit, the jaw angle parameter can be assigned numerical values for greater weight in the across-word boundary condition, which in turn gives rise to lower jaw position. Speech rate-dependent spatial reduction in lip aperture may be able to be resolved by means of manipulating activation time of an active tract variable in the gestural score level.

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

Hydramnios related to fetal deformity in a Hanwoo cow: a case report

  • Jae Kwan Jeong;Sanggu Kim;Ui Hyung Kim;Dongwoo Chang;Soochong Kim;Ill Hwa Kim
    • Korean Journal of Veterinary Research
    • /
    • v.62 no.4
    • /
    • pp.32.1-32.4
    • /
    • 2022
  • A Hanwoo cow with a delayed gestation and abdominal distension was delivered following PGF injection. There was excessive amniotic fluid, and a male calf was delivered but died immediately. The calf had no eyes and nose, and a cleft palate on the upper jaw. Gross appearance and computed tomography image showed that upper teeth were spread out on both sides due to cleft palate in the upper jaw, and lower jaw and teeth were positioned upward. There were no other brain parts except cerebellum. These findings show a rare case of hydramnios related to fetal congenital deformity in a Hanwoo cow.

A Study on Clamping Characteristics of Jaw-wedge for Automatic Jig Vise (자동 지그 바이스용 조오-웨지의 클램핑 특성 연구)

  • Jung, Si-Kyo;Maeng, Hee-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.6
    • /
    • pp.745-750
    • /
    • 2011
  • A jig vise is a device to clamp workpiece precisely, which is widely used for various machine tools and manufacturing purpose. A new elastic structured jaw-wedge of jig vise is developed, in this paper, so as to satisfy the clamping requirement and the suppression effect of upright movement of workpiece. The advanced design parameters of jaw-wedge are derived step by step considering the stress distribution and the displacement profiles of ANSYS analysis, and it could find the optimum model which shows the uniform displacement profiles and exhibits the non-concentrated stress distribution of jaw neck. As a result, it is ascertained that an jaw-wedge developed in this study is the simple elastic structure which is effective for automatic multiple clamping purpose without the danger of shear crack or bucking of jaw.

The study on dose variation due to exchange of Upper and Lower jaw in the linear accelerator (선형가속기에서 상위조리개와 하위조리개의 교환에 의한 선량 변화의 고찰)

  • Lim CK.;Kim HN.;Song KW.
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.6-10
    • /
    • 1999
  • The field size can be beam output, therefore MonitorUnit can be varied due to field size dependence The purpose of this study is to evaluate and compare the dose variation according to exchange of collimator The measurements were perfomed with Wellhofer dosimetry system(water phantom. ion chamber. electrometer. system controller. build up cap. etc)and two types of linear accerlerator (Mevatron KD, MevatronMX) Scatter can be affected to field size dependence and scatter correction is separated into collimator and phantom components, scatter components can affect by exchanging of collimator Measurements of collimator scatter factor(Sc) was done in air with build up cap. 1)Square field (5cm2 to 40cm2) was measured 2)and then keeping the upper jaw constant at loom and varing lower jaw from 5cm to 40cm, 3)keeping the lower jaw constant at 10cm and varing upper jaw from 5cm to 40cm Measurements of total scatter factor(Scp) was done in water at Dmax as the procedure of collimator scatter factor measurements in water Dmax The total scatter factors were obtained to the following equation(Sp=Scp/Sc) The measured data is normalized to the data of reference field size($10{\times}10$), rectangular field is inverted to equivalent field to compare three field size data As the collimator setting is varied, the output was changed In conclusion, the error was obtained small but it must be eliminated if we intend to reach the common stated goal of $5\%$ overall uncertainty in dose determination

  • PDF

A Statistical Study on the Tooth Mortality and Replacement of Korean (한국인(韓國人)의 치아상실(齒牙喪失)과 회복(回復)에 관(關)한 통계학적(統計學的) 고찰(考察))

  • Kim, Myong-Dong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.9-14
    • /
    • 1968
  • A total of 11,039 permanent missing teeth and their 2,696 prosthetic replaced teeth in 6,123 Korean patients were selected for this study, Analyzing the data according to age, sex, jaw and the location, following results were obtained. 1. Tooth mortality and replacement were higher in female than in male. 2. Replaced teeth were only 24 percent of missing teeth. 3. More teeth were extracted and replaced on lower jaw in young patients and on upper jaw in old patients. 4. There are no significant difference in right and left sides of both jaws in missing and replaced teeth, respectively. 5. First molar was the highest percentage in both mortality and replacement. 6. Upper tooth mortality and replacement were higher in anterior portion and lower in posterior portion.

  • PDF