• Title/Summary/Keyword: KOSEP

Search Result 8, Processing Time 0.017 seconds

Energy Theme Park Design in Yeong-Heung Island (영흥 에너지 테마파크 조경설계)

  • Lee Shi-Young;Cho Kwang-Young;Kim Shin-Won
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.2 s.109
    • /
    • pp.100-110
    • /
    • 2005
  • The Korea South-East Power Co., Ltd.(KOSEP) held a design competition for Energy Theme Park at Yeong-Heung power plant in October, 2004. The site is located in 980-1 Oe-ri, Yeong-Heung myun, OngJin gun, Incheon City and has an area of $54,450m^2$. Design objectives of KOSEP were to make environmentally sustainable space, to build a symbolic and gathering place for community members and visitors, to make a tourist spot of Yeong-Heung Island linked with adjacent sight spots in OngJin gun, and to elevate an identity and status of the KOSEP by creating a landscape correspondent to the concept of the building design. The spatial concept of this project was developed by expressing a circular course of energy, named 'energy circle' and accounting for principles of energy generation. By interpreting 'energy circle' and principles of energy generation, and applying it to the site, the design met the various desires of the KOSEP. This design consists of seven theme spaces; the future energy plaza, the wind plaza, the light plaza, the thermal power plaza, a water strider dam, a ecological pond and the stratum plaza. These theme spaces are consecutively placed along the circular path which surrounds the public information building and to represent how power plants generate energy in each space and diverse design techniques and special effects are used.

A Study on Contents for Safety education of The Power Plant applied to the Story-viewing (스토리뷰잉을 적용한 발전소 안전교육 콘텐츠)

  • Min, soel-hui;Choi, sung-wook;Song, in-heon;Hong, sam-dong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.439-440
    • /
    • 2015
  • There has been a big need of Safety Education for the power plants with a high risk due to the Fukushima Daiichi nuclear disaster and the tragic accident of Sewol Ferry. The object of this research is for studying ways of developing contents for customized Power Plants Safety Education applied with 'Story Viewing' technology in order to improve the present format of Power Plant Safety Education based on hard copied documents so as to prevent human mistakes because of lack of system and ability of initial response which come from safety frigidity shown in the case of Sewol Accident. 'Story-viewing' applied to Power Plant Safety Education is the methodology to enhance information communicability utilizing IT/Visualization technology combined with Story Telling that is an effective propagation way.

  • PDF

Combustion Characteristics of Coal-Fired Boiler Depending on the Variations in Combustion Air Supply Method (미분탄 보일러의 연소용 공기공급 변화에 따른 노내 연소상태 해석)

  • Seo, San-Il;Park, Ho-Young;Kang, Dong-Soo;Jeong, Dong-Hae
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.156-162
    • /
    • 2010
  • 3-D CFD(Computational Fluid Dynamics) work were carried out to investigate the combustion characteristics in a boiler depending on the variations in air supply condition. For the gas temperature, $O_2$, NO, SOx at the outlet of economizer, the predicted values were been compared with the measured data. With the verified CFD model, the effects of air flow rates through SOFA(Separated Over Fire Air) and CCOFA(Closed Coupled Over Fire Air) on the combustion behavior in a boiler were simulated, and the distributions of NOx and gas temperature were mainly compared each other. The change in SOFA air flow rate gave the more sensitive effect on NOx than that in CCOFA. The distributions of gas temperature at convection path are differed with the changes in SOFA and CCOFA flow rate, so the combustion modification such as yaw anlge adjustment are required to get an enhanced gas temperature distribution.

Reliability Improvement Method of Weld Zone in Water Wall Tube for an Ultra Supercritical Coal Fired Boiler (초초임계압 석탄화력 보일러 수냉벽 수관의 용접신뢰성 향상방안)

  • Ahn, Jong-Seok;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.6 no.3
    • /
    • pp.53-61
    • /
    • 2010
  • This paper presents failure analysis on weld-joint of the waterwall tubes in USC boilers. Visual inspections were performed to find out the characteristics of the fracture. Additionally both microscopic characteristics and hardness test were carried out on failed tube samples. Failures seem to happen mainly because the welding process such as preheating and PWHT(post-weld heat treatment) was not conducted strictly. Thus, this paper has the purpose to describe the main cause of the poor welding process and to explain how to prevent similar failures in those weld-joints.

  • PDF

Selection of the Protective Coating Material for Blades of a Booster Fan in Desulfurization Plant (탈황설비용 부스터팬 블레이드의 코팅재질 선정에 관한 연구)

  • Jeong, Byeong-Yong;Yoo, Hoseon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.6 no.3
    • /
    • pp.46-52
    • /
    • 2010
  • This study investigated the coating failure of the blades of booster fans for the 200 MW flue gas desulfurization plant. Although the arc sprayed SM8222 have been tried as blade coating materials aimed to apply as alternatives of Metcoloy(R)2 due to better corrosion-erosion resistance but it is failed. Bond strength tests and practical field experiences have demonstrated high velocity oxy-fuel(HVOF) coating method with Diamalloy 3004 as an alternative to Metcoloy(R) 2 arc spray.

  • PDF

Characteristics of the Post-Weld Heat Treatment of Chrome Low Alloy Material for a Power Plant Boiler (발전 보일러용 크롬 저합금강의 용접후열처리 특성)

  • Whe, Jae-Hoon;Moon, Seung-Jae;Yoo, Hoseon
    • Plant Journal
    • /
    • v.6 no.4
    • /
    • pp.56-62
    • /
    • 2010
  • This study investigated characteristics of the post-weld heat treatment of SA213-T23, which was developed for water wall of the ultra super critical power boiler. The temperature of post weld heat treatment should be $730^{\circ}C$ or higher to reduce hardness of the deposit metal and heat affected zone. Coincidently, the temperature should remain $760^{\circ}C$ or lower to prevent hardness of the base metal from dropping. Hardness decline of deposit metal was trivial according to time when the holding time of heat treatment at $740^{\circ}C$ of post-weld heat treatment gradually increased from initial 15 minutes.

  • PDF

The study of plant application at flame management system with flame monitoring for pulverized coal firing boiler of thermal power plant (발전용 미분탄 연소 보일러 화염감시장치의 현장적용에 관한 연구)

  • Baeg, Seung-Yeob;Kim, Seung-Min
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.535-537
    • /
    • 2004
  • The flame image processing and it's analysis system has been developed for optimal coal firing of thermal power plant, especially for reducing NOx and safe operations. We aimed at gaining the relationship between burner flame image, emissions of NOx and LOI(Loss on ignition) in furnace by utilizing the flame image processing methods. And the relationship determines quantitatively the conditions of combustion on the individual burners. The test was conducted on Samchonpo thermal power plant #4 unit(560MW) of KOSEP which has 24 burners. The system simplified the burner adjustment works in accordance with the real time trending of flame behavior like NOx profiles and unburned carbon profiles for individual burners. But, This kind of conventional method increases the cost as the number of burner are increased. Also there is a difficulty to measure exhausted gas of each burner because of measurement errors. This paper intends to propose the useful "Flame Monitoring System" that can find Low NOX and LOI at the upper furnace and to compare with the conventional System.

  • PDF

A Survey of Deterioration Causes of High Voltage Motors in Power Plants (발전소 고압전동기 열화 요인 분석)

  • Kim, Kyeong-Yeol;Kim, Hee-Dong;Kim, Byeong-Rae;Kong, Tae-Sik;Kim, Byong-Han;Lee, Sang-Kil;Lee, Jong-Hweon;Choi, Hong-Suck
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.10
    • /
    • pp.807-811
    • /
    • 2011
  • When the high voltage motor fails in power plants, there will be an occurrence where the generator's output would be reduced or the generators would trip. Despite of these effects, the causes of deterioration of the high voltage motor is very seldom investigated. In this paper, the collected data which tested in the field over 10 years have been treated statistically, and analyzed to correlate the insulation deterioration of high voltage motor and installation environment, number of start/stop, and service life. Moreover, the proper period of insulation test is developed to map out maintenance strategy and reduce maintenance costs.