• Title/Summary/Keyword: Kim-test

Search Result 52,554, Processing Time 0.083 seconds

The design of C-GIS and the analysis of its Performance test results (C-GIS의 설계 및 성능평가 결과분석)

  • Shin, Y.J.;Kim, M.H.;Ryu, H.K.;Lee, Y.H.;Kim, C.H.;Kim, J.K.;Kim, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.551-553
    • /
    • 2002
  • The cubicle type GIS rated at 25.8kV has been designed and manufactured by Jinkwang E&C eacently with their own technologies and KERI's assistances. The C-GIS has been tested to check the design capability for reference before conducting the type test. The operating characteristics test, short time withstand current and peak withstand current test, basic short circuit test duty T60 for preconditioning test, cable charging current switching test, capacitor bank current switching test, basic short circuit test duty T100s and T100a, single phase earth fault test, double earth fault test has been conducted. The test results show that the design and the manufacturing of the C-GIS has an enough capability to pass through the type test except the occurrence of 2 NSDDs in the cable charging current switching test and the instability of opening time at the minimum operating voltage. The problems shown in the tests will be improved soon and the successful pass will be expected in the following type test.

  • PDF

Lee-Kim Test of Korean Articulation Using Multimedia Computer Software (컴퓨터를 이용한 한국어 발음 검사)

  • Lee Hyun Bok;Kim Sun Hee;Chung Tae-Choong
    • Proceedings of the KSPS conference
    • /
    • 1996.10a
    • /
    • pp.421-425
    • /
    • 1996
  • A multimedia Version of ${\ulcorner}Lee-Kim test of Korean Articulation{\lrcorner}$ "Lee-Kim Test of Korean Articulation" consisting of picture test, Sentence test, user's manual and notation, analysis sheets was published in 1990 to serve as a standard tool for testing and analysing the articulation errors of normal and abnormal speakers. It has been found, however that, the picture and sentences test using the printed version of Lee-Kim test of Korean Articulation revealed several limitations, in i, e, a) inefficiency in inducing desirable response from the informants b) lack of concentration and interest on the part of informants c) no consistent way of providing the informant with a clue in case the informant is unfamiliar with the word represented by the picture or the sentence. d) no reliable means for the speech-language pathologist to analyze and evaluate the informant's speech in relation to the standard pronunciation A multimedia version of Lee-Kim Korean articulation Test which features picture and word as well as recorded voice has been developed with a view to eliminating the limitation mentioned above and facilitating the articulation test-with ease and accuracy.

  • PDF

The General Linear Test in the Ridge Regression

  • Bae, Whasoo;Kim, Minji;Kim, Choongrak
    • Communications for Statistical Applications and Methods
    • /
    • v.21 no.4
    • /
    • pp.297-307
    • /
    • 2014
  • We derive a test statistic for the general linear test in the ridge regression model. The exact distribution for the test statistic is too difficult to derive; therefore, we suggest an approximate reference distribution. We use numerical studies to verify that the suggested distribution for the test statistic is appropriate. A asymptotic result for the test statistic also is considered.

Dynamic Test Results Assessment on the Optical Bench of LEO Satellite (저궤도 지구관측위성의 광학탑재체 지지구조물 동환경시험 결과분석)

  • Kim, Kyung-Won;Kim, Jin-Hee;Rhee, Ju-Hun;Kim, Sun-Won;Jin, Ik-Min;Park, Jong-Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.242-245
    • /
    • 2006
  • This paper is an assessment on the dynamic test results of optical bench for LEO satellite. According to the design requirements, optical bench was designed and manufactured. Dynamic test was performed to verify stability of optical bench. Low level random vibration test, sine burst test and sine vibration test are carried out to identify dynamic characteristics and to verify static strength and safety under quasi-static load conditions. From the result it can be stated that the optical bench is well qualified under the launch environmental conditions.

  • PDF

Aircraft Engine Performance Test Technologies by 150K lbf Thrust Test Cell (15만 파운드급 테스트 셀을 이용한 엔진성능 시험기술)

  • Kim, Woocheol;Kim, Chul;Kim, Sangbaek
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.180-187
    • /
    • 2017
  • Major design targets such as test cell type, cell flow, cell bypass ratio, approach velocity, cell depression, front cell distortion, noise level and vibration level to construct a new 150,000 lbf thrust aircraft engine test facility were established. Based on the final aerodynamic and acoustic performance tests conducted at the newly constructed test facility, it was found that the new test facility is judged to be excellent and meets design targets.

  • PDF

Compatibility test of a non-instrumented irradiation test capsule for the HANARO test reactor (환형소결체 하나로 조사시험용 무계장 캡슐의 연구로 설치 적합성시험)

  • Lee, Kang-Hee;Kim, Dae-Ho;Chun, Tae-Hyun;Kim, Hyung-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.226-229
    • /
    • 2008
  • To investigate an in-pile behavior of the newly developed DUO fuel pellet, the irradiation test will be carried out in the domestic test reactor. Irradiation test capsule for the HANARO reactor, which is a specially designed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this study, a pressure drop, a flow-induced vibration and a short-term endurance test for the newly developed non-instrumented test capsule were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin.

  • PDF

Highly Accelerated Life Tests for Auto-Connector in Use-Environment (자동차 환경을 고려한 커넥터의 가속시험에 관한 연구)

  • Kim Jong-Gurl;Kim Jin-Hawn
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.11a
    • /
    • pp.229-235
    • /
    • 2004
  • This paper treats accelerated life tests for automotive connector. The contact resistance of connector is explained by some factors; the use time(calender time, real cycle), stresses and loads adapted in auto test. The relationships between contact resistance and some factors are compared and analyzed by regression models in various test conditions; field use-environment, manufacturer's test environment, and accelerated test condition. The consistency between of manufacturer's test and field test is examined. Finally, the future study on accelerated test for automotive connector is presented.

  • PDF

Performance evaluation facilities and evaluation methods for hydropower equipment (해외 수력발전설비 성능평가설비 및 평가 방법)

  • Kim, Youngjoon;Kim, Yongyeol;Cho, Yong;Ko, Jaemyoung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.194-194
    • /
    • 2010
  • The variable demand on the energy market, as well as the limited energy storage capabilities, requires a great flexibility in operating hydraulic turbines. But, present in Korea, the absence of testing laboratories and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic hydropower machines, A performance guarantees for hydro turbines shall be contain, as a minimum, guarantees covering power, discharge and specific hydraulic energy, efficiency, maximum momentary overspeed and maximum momentary pressure and/or maximum steady-state runaway speed, as well as guarantees related to cavitation. Performance test are conducted by the test standard. Test codes based on extensive research data are written under the leadership of an IEC. Performance evaluation is carry out several test(performance test, cavitation test and runaway test). The paper presents the international turbine test laboratory and performance test standard.

  • PDF