• Title/Summary/Keyword: LAN cable

Search Result 35, Processing Time 0.021 seconds

Design of UTP LAN Cable With Enhanced Alien Crosstalk Characteristic (이질 누화 특성이 개선된 UTP LAN 케이블의 설계)

  • Kim, June-Hyong;Lee, Seong-Jun;Oh, Sung-Ki
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37A no.12
    • /
    • pp.1115-1121
    • /
    • 2012
  • In this paper, the design of UTP LAN cable with enhanced alien crosstalk characteristic is proposed. Proposed LAN cable is made with jacket of the irregularly corrugation type. If necessary, it is possible to use the special cross-filler. The alien crosstalk characteristic is enhanced by using proposed cable with inner jacket of the irregularly corrugation type in wide frequency band. The design of the cable was based on parameters of the standard EIA/TIA 568-B.2-10.

Condition Monitoring System: High Performance Wireless Measurement System (기계 상태 감시: 임베디드형의 고성능 무선 측정시스템)

  • Shim, M.C.;Yang, B.S.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.28-32
    • /
    • 2007
  • This research proposed that development of wireless condition monitoring system using WLAN network. It offers the prospect of improved performance that removed a current a coaxial cable and reduced overall cost of condition monitoring. Recently, there is an interesting concern for wireless system as an infrastructure technology construct ubiquitous computing environment in the future. High performance computing board makes minimization with integrate of a various functions which support wireless LAN network. Instead of wired coaxial cable using measurement system in industry, wireless LAN network assists industry automation and engineer's convenience. Developed system adapted wireless LAN network on shipboard with engine room and deck house, it also executes wireless measurement test on 8500TEU containership.

  • PDF

The USB Multi-signal Transmission System (USB 다중 신호 전송 시스템)

  • Chae, Jung-Sik;Kim, A-Yong;Jung, Hoe-Kyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.6
    • /
    • pp.1330-1335
    • /
    • 2013
  • In recent years, the need to simultaneously transmit a variety of signals, such as DVI(Digital Visual Interface), audio, video, USB(Universal Serial Bus), LAN from the computer is required. So the cable complexity and scalability issues have been raised. In this paper, this signal can be distributed using a single USB cable, computer, video, audio, USB, LAN, one USB multi-signal transmission system was designed and implemented. USB multi-signal transmission was implemented in order to convert a single DVI, audio, and multiple USB, LAN, USB signal converter modules. This USB DVI port supports up to 1920 * 1080 resolution. USB multi-signal transmission system by sending multiple signals into a single cable installation costs of the various cable and using the replication feature of the screen, will provide schools and institutes, etc., providing the convenience of the river, and the scalability of computer peripheral ports.

Elimination of environmental temperature effect from the variation of stay cable force based on simple temperature measurements

  • Chen, Chien-Chou;Wu, Wen-Hwa;Liu, Chun-Yan;Lai, Gwolong
    • Smart Structures and Systems
    • /
    • v.19 no.2
    • /
    • pp.137-149
    • /
    • 2017
  • Under the interference of the temperature effect, the alternation of cable force due to damages of a cable-stayed bridge could be difficult to distinguish. Considering the convenience and applicability in engineering practice, simple air or cable temperature measurements are adopted in the current study for the exclusion of temperature effect from the variation of cable force. Using the data collected from Ai-Lan Bridge located in central Taiwan, this work applies the ensemble empirical mode decomposition to process the time histories of cable force, air temperature, and cable temperature. It is evidently observed that the cable force and both types of temperature can all be categorized as the daily variation, long-term variation, and high-frequency noise in the order of decreasing weight. Moreover, the correlation analysis conducted for the decomposed variations of all these three quantities undoubtedly indicates that the daily and long-term variations with different time shifts have to be distinguished for accurately evaluating the temperature effect on the variation of cable force. Finally, consistent results in reducing the range of cable force variation after the elimination of temperature effect confirm the validity and stability of the developed method.

A Study on the Modified PRMA-TDD Method for Media Access in Wireless LANs (무선 LAN에서 매체처리를 위한 변형된 PRMA-TDD 방식에 관한 연구)

  • 서정곤;홍성식;류황빈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.7
    • /
    • pp.1244-1255
    • /
    • 1994
  • The wireless-LAN(Local Area Network), which is emerged as a solution to cable problem and increasing requirement for communication network, has a several problem when it transmit information MAN protocol by used wired-LAN`s MAC protocol. Media Access protocol in Wireless-LAN has great effect on system performance and much studies are processing now. The PRMA(Packet Reservation Multiple Aeecss) of reservation method has a disadvantage that the system performance was degraded become of delay time in the reservation step as a resulting of collision. In this paper, using the TDD(Time Division Duplex) method amd modified PRMA method wireless-LAN modelled to overcome disadvantage, that id delay time due to collision in reservation step. The performance evaluation fo the model was done using M/M/1//M process model and this was simulation using SLAM.

  • PDF

Design and Implementation the USB Multi-signal Transmission System (USB 다중 신호 전송 시스템 설계 및 구현)

  • Chae, Jung-Sik;Kim, Jong-Moon;Kim, Chang-Su;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.623-625
    • /
    • 2013
  • This signal can be distributed using a single USB cable, computer, video, audio, USB, LAN, one USB multi-signal transmission system was designed and implemented. USB multi-signal transmission was implemented in order to convert a single DVI, audio, and multiple USB, LAN, USB signal converter modules. This USB DVI port supports up to 1920 * 1090 resolution. USB multi-signal transmission system by sending multiple signals into a single cable installation costs of the various cable and using the replication feature of the screen, will provide schools and institutes, etc., providing the convenience of the river, and the scalability of computer peripheral ports.

  • PDF

A Study on the Development of K-LAN Hardware (K-LAN 하드웨어 개발에 관한 연구)

  • Park, H.D.;Chung, K.S.;Choi, Y.H.;Chung, S.J.
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.3
    • /
    • pp.289-294
    • /
    • 1986
  • In this paper, we describe the development of an NIU (network interface unit) hardware for sharing computer resources and exchanging haigh-speed information between information systems distributed in a local area. The NIU designed and implemented in accordance with Ethernet specifications is operating normally with the upper layer software. Modular design makes it simple to change or expand the functions of the NIU. The NIU's are connected to 10Mbps coaxial cable through transceivers. In addition, a system and a design specifications for the NIU of a broadband LAN based on the K-LAN NIU are porposed.

  • PDF

Prototype design of fiber optics based 765kV substation control system (광 LAN을 적용한 765kV변전소 감시제어 시범시스템 설계)

  • 송인호;박종화;최종협
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.996-999
    • /
    • 1996
  • This paper introduces prototype design of 765kV Substation control system based on fiber optics LAN and distributed network protocol. Two major important facts, immunity of any surge which frequently occurs in Ultra High Voltage Substation and the most suitable communication protocol for substation control system, are considered on the system design conception. To meet the first fact, use of fiber optics cable and isolation transformer are considered, and to satisfy the second fact, DNP3.0(Distributed Network Protocol) which is IEC870-5 compatible is adopted.

  • PDF

Damage detection of a cable-stayed bridge based on the variation of stay cable forces eliminating environmental temperature effects

  • Chen, Chien-Chou;Wu, Wen-Hwa;Liu, Chun-Yan;Lai, Gwolong
    • Smart Structures and Systems
    • /
    • v.17 no.6
    • /
    • pp.859-880
    • /
    • 2016
  • This study aims to establish an effective methodology for the detection of instant damages occurred in cable-stayed bridges with the measurements of cable vibration and structural temperatures. A transfer coefficient for the daily temperature variation and another for the long-term temperature variation are firstly determined to eliminate the environmental temperature effects from the cable force variation. Several thresholds corresponding to different levels of exceedance probability are then obtained to decide four upper criteria and four lower criteria for damage detection. With these criteria, the monitoring data for three stay cables of Ai-Lan Bridge are analyzed and compared to verify the proposed damage detection methodology. The simulated results to consider various damage scenarios unambiguously indicate that the damages with cable force changes larger than ${\pm}1%$ can be confidently detected. As for the required time to detect damage, it is found that the cases with ${\pm}2%$ of cable force change can be discovered in no more than 6 hours and those with ${\pm}1.5%$ of cable force change can be identified in at most 9 hours. This methodology is also investigated for more lightly monitored cases where only the air temperature measurement is available. Under such circumstances, the damages with cable force changes larger than ${\pm}1.5%$ can be detected within 12 hours. Even though not exhaustively reflecting the environmental temperature effects on the cable force variation, both the effective temperature and the air temperature can be considered as valid indices to eliminate these effects at high and low monitoring costs.

Field Application of a Cable NDT System for Cable-Stayed Bridge Using MFL Sensors Integrated Climbing Robot (누설자속센서를 탑재시킨 이동로봇을 이용한 사장교 케이블 비파괴검사 시스템의 현장 적용)

  • Kim, Ju-Won;Choi, Jun-Sung;Lee, Eun-Chan;Park, Seung-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.1
    • /
    • pp.60-67
    • /
    • 2014
  • In this study, an automated cable non-destructive testing(NDT) system was developed to monitor the steel cables that are a core component of cable-stayed bridges. The magnetic flux leakage(MFL) method, which is suitable for ferromagnetic continuum structures and has been verified in previous studies, was applied to the cable inspection. A multi-channel MFL sensor head was fabricated using hall sensors and permanent magnets. A wheel-based cable climbing robot was fabricated to improve the accessibility to the cables, and operating software was developed to monitor the MFL-based NDT research and control the climbing robot. Remote data transmission and robot control were realized by applying wireless LAN communication. Finally, the developed element techniques were integrated into an MFL-based cable NDT system, and the field applicability of this system was verified through a field test at Seohae Bridge, which is a typical cable-stayed bridge currently in operation.