• Title/Summary/Keyword: LC resonance

Search Result 157, Processing Time 0.034 seconds

Simple Synthetic Testing Facility Using LC Resonance Circuit (LC 공진회로를 이용한 간이 합성시험설비)

  • Park, J.H.;Shin, Y.J.;Park, K.Y.;Ryu, H.G.;Kim, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.631-635
    • /
    • 1993
  • This paper shows the procedure to determine the physical variables of the simple synthetic testing facility using LC resonance circuit and presents the calculated results of those variables for the LC resonance circuit which can be used to test circuit breakers up to 36kV 40kA class. Attention has also been paid to the advantages of the LC resonance circuit compared with the method adopting short-circuit generator for the development of circuit breakers.

  • PDF

Fault Current Waveform Analysis of a Flux-Lock Type SFCL According to LC Resonance Condition of Third Winding

  • Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.213-217
    • /
    • 2008
  • The flux-lock type superconducting fault current limiter(SFCL) can apply the magnetic field into the high-$T_C$ superconducting(HTSC) element by adopting the magnetic field coil in its third winding. To apply the magnetic field into the HTSC element effectively, the capacitor for LC resonance is connected in series with the magnetic field coil. However, the current waveform of third winding for the application of the magnetic field is affected by the LC resonance condition for the frequency of the source voltage and can affect the waveform of the limited fault current. In this paper, the current waveform of the third winding in the flux-lock type SFCL according to LC resonance condition during a fault period was analyzed. From the differential equation for its electrical circuit, the current equation of the third winding was derived and described with the natural frequency and the damping ratio as design parameters. Through the analysis according to the design parameters of the third winding, the waveform of the limited fault current was confirmed to be influenced by the current waveform of the third winding and the design condition for the stable fault current limiting operation of this SFCL was obtained.

A Telemetry Silicon Pressure Sensor of LC Resonance Type (LC공진을 이용한 원격측정용 압력센서의 제작 및 실험)

  • Kim, Hak-Jin;Kim, Soon-Young;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1872-1874
    • /
    • 2001
  • This paper presents an implantable telemetry LC resonance-type pressure sensor to measure the cerebral ventricle pressure. The sensor consists of an inductor and a capacitor. The LC resonant circuit consists of the sensor and an external antenna coil that are coupled magnetically. The resonance frequency of the circuit decreases as the applied pressure increases the capacitance of the sensor. The sensor is designed in consideration of the biocompatibility and long lifetime for continuous monitoring of the ventricle pressure. The sensor is simple to fabricate and small in comparison with others reported previously. The inductor is fabricated by electroplating and the variable capacitor is constructed with a flexible p+ diaphragm. Also, the deflection of the diaphragm, the variation of the capacitance and the resonance frequency are analyzed and calculated.

  • PDF

Design of the Protection circuit for Electric ballast with $LC_SC_P$ resonance type Half-bridge Inverter ($LC_SC_P$ 공진 타입의 하프 브리지 인버터 구조를 가지는 전자식 안정기 보호회로 설계)

  • Choe, Hyeon-Hui;Park, Chong-Yun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1538-1543
    • /
    • 2009
  • The electric ballast for ceramic metal halide lamp needs a protection circuit to prevent from over voltage and over current in the case that the lamp or the electric ballast are in faults. In this paper, cost-effective and high performance protection circuit is proposed for the electric ballast. The proposed protection circuit is adapted to the electric ballast with $LC_SC_P$ resonance type half bridge inverter. The experimental results demonstrate that the proposed circuit can protect effectively under open and short fault conditions.

Displacement Sensor Fabricated with LC Resonators (LC공진소자를 이용한 변위센서)

  • Shin, Kwang-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.1
    • /
    • pp.27-30
    • /
    • 2015
  • In this study, the LC resonators were fabricated with ferrite cores and external capacitors, and then their characteristics were investigated for the purpose of developing new displacement sensor. The frequency dependence of impedance of single resonator was estimated. There were two resonance peaks on the impedance spectrum; one by self inductance and the other by mutual inductance. The resonance frequency was shifted linearly in direct proportion to displacement of the resonator showing the proposed device, a pair of LC resonators, could be used a precision displacement sensor.

Telemetry Silicon Pressure Sensor Using LC Resonance (LC 공진을 이용한 원격측정용 실리콘 압력센서)

  • Kim, Soon-Young;Pak, Jean-Sung;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2254-2256
    • /
    • 2000
  • This paper presents an implantable telemetry LC resonance-type pressure sensor for the measurement of the ventricle pressure. This sensor consists of a capacitor and an inductor. This resonant circuit is magnetically coupled with an external antenna coil. The resonance frequency of the circuit decreases as the sensor capacitance is increased by the applied pressure. The inductance and the capacitance are 428nH and 0.98${\mu}F$, respectively. The resonance frequency is 245.7MHz when the differential pressure is zero. The sensitivity of the sensor is 9.477kHz/Pa.

  • PDF

NMR Characterization of Oxidized Form of Human 8-kDa Dynein Light Chain

  • Shin, Jae-Sun;Jeong, Woo-Jin;Chi, Seung-Wook
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.14 no.2
    • /
    • pp.127-133
    • /
    • 2010
  • Redox-dependent conformational change of human 8-kDa Dynein light chain (LC8) plays important role in regulating NF-${\kappa}B$ signaling pathway. In this study we characterized the structural states of the oxidized and reduced forms of LC8 by using NMR spectroscopy. The $^1H-^{15}N$ 2D HSQC spectra of oxidized LC8 indicated that no significant change in tertiary structure of LC8 occurred upon oxidation. The chemical shift perturbations of LC8 upon oxidation suggest a redox-dependent quaternary structural change.

Construction of Simple Synthetic Testing Facility Using LC Resonance Circuit (L-C 공진회로를 이용한 대용량 간이 합성시험 설비 구축)

  • Kwon, G.J.;Kim, D.S.;Song, W.P.;Kwon, G.Y.;Chung, J.M.;Park, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.409-411
    • /
    • 1999
  • This paper proposes the circuit of the simple synthetic testing facility using LC resonance circuit. EMTP has been used to analyze the circuit. The obtained results indicate that the simple synthetic testing facility using LC resonance circuit can be easily designed and used very usefully for the research and development for the switchgears.

  • PDF

A LC Series Resonant Boost Converter Using a Single Switch (단일 스위치를 사용한 LC직렬 공진형 부스트 컨버터)

  • Park, Kun-Wook;Jung, Doo-Yong;Ji, Young-Hyok;Jung, Yong-Chae;Han, Hee-Min;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.432-440
    • /
    • 2010
  • In this paper, a LC series resonant boost converter using a single switch is proposed. The proposed topology contains additional passive elements in the conventional boost converter and performs Zero Voltage Switching(ZVS) without an additional auxiliary switch when a main switch turned on and off. The switch off time of the proposed system determined by LC series resonance, thus a on-time variable Pulse Frequency Modulation(PFM) method is adapted to control output voltage in the proposed converter. Operational modes of the proposed topology are divided with respected to the current conduction paths and then through the theoretical analysis and experimental results, operational modes and characteristics of the proposed converter are verified.