• Title/Summary/Keyword: LPG filling station

Search Result 13, Processing Time 0.029 seconds

Validity of solar energy generation at the underused Space of LPG filling station (LPG충전소 유휴공간의 태양광발전설비 설치 유효성)

  • Lee, Minkyung;Kim, Jeonghwan;Lee, Jinhan;Joe, Youngdo;Lee, Yeonjae
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.4
    • /
    • pp.25-32
    • /
    • 2016
  • The purpose of this study is safety evaluation of solar energy generation which is installed on the canopy at the LPG filling station. in case of a gas station, the solar energy generation was become legalization through a related law reform in 2008. Also, in case of a LPG filling station, the solar energy generation was become legalization through a related law reform in 2015. So, the related law that KGS CODE and Safety control of dangerous substances law and the case of installed solar energy generation in gas, LPG filling station was investigated. two scenarios are supposed for the CFD. Release of safety valve pipeline and ruptured dispenser leakage are the scenarios. The FLACS which developed GexCon in Norway was used for simulation. LPG dispersion to the upper side of canopy was very small with safety distance.

A Study on the Estimation of Human Damage Caused by Vapor Cloud Explosion(VCE) in LPG Filling Station (LPG자동차충전소에서 증기운폭발로 인한 인명피해예측에 관한 연구)

  • Leem, Sa-Hwan;Huh, Yong-Jeong
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.15-21
    • /
    • 2010
  • The demand of gas as an eco-friendly energy source has being increased. With increasing the LPG demand, the number of LPG filling station. In this work, the influence on over-pressure caused by Vapor Cloud Explosion in gas station was calculated by using the Hopkinson's scaling law and injury effect by the accident to a human body was estimated by applying the probit model. As a result of the injury estimation conducted by using the probit model for leakage 10% of 20ton storage tank. The distances from LPG station for death and tympanum rupture are 36.5 and 290 meters, respectively.

A Study on the Quantitative Analysis and Estimation for Surround Building caused by Vapor Cloud Explosion(VCE) in LPG Filling Station (LPG충전소에서 증기운폭발이 주변건물에 미치는 영향의 정량적 해석 및 평가에 관한 연구)

  • Leem, Sa-Hwan;Huh, Yong-Jeong
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.1
    • /
    • pp.44-49
    • /
    • 2010
  • This paper is estimation of structure damage caused by Explosion in LPG(Liquefied Petroleum Gas) filling station. As we estimate the influence of damage which occur at gas storage tank in filling station. We can utilize the elementary data of safety distance. In this study, the influence of over-pressure caused by VCE(Vapor Cloud Explosion) in filling station was calculated by using the Hopkinson's scaling law and the accident damage was estimated by applying the influence on the adjacent structure into the probit model. As a result of the damage estimation conducted by using the probit model, both the damage possibility of explosion overpressure to structures of max 265 meters away and to glass bursting of 1150 meters away was nearly zero in open space explosion.

A Study on the Economic Analysis for Installation Method of Storage Tank in LPG Filling Station (LPG 충전소 저장탱크의 설치방법에 따른 경제성 분석에 관한 연구)

  • Huh, Yong-Jeong;Lim, Ju-Yeon;Youm, Moo-Youl;Leem, Sa-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.1
    • /
    • pp.23-28
    • /
    • 2016
  • "Eco-friendly" automobile has been a symbol of the Low Carbon, Green Growth strategy that Korea government decided to pursue. In line with the recent policy trend, a number of new LPG stations are being constructed. However, communities where mass storage are installed have been suffered from risk of serious accidents. In this work, economic analyses for different installation methods has been performed to prevent accidents in LPG filling station. The review shows that the underground storage is beneficial for the maintenance and the effective land use.

An Availability Assessment of Protection Wall Installed in LPG Filling Station (LPG 충전소 내 설치된 방호벽의 효용성 평가)

  • Lee, Jin-Han;Jo, Young-Do;Moon, Jong-Sam;Kim, Lae Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.38-45
    • /
    • 2018
  • Jet fire, pool fire, and vapor cloud explosion are major accident scenarios in LPG filling station. The protection wall would mitigate radiation effect in a jet fire. In case of a pool fire, the protection wall would restrict expanding the pool area. The protection wall might both obstruct the dispersion of released vapor and protect blast overpressure in a vapor cloud explosion scenario. In this paper, An availability assessment method of the protection wall how much reduce damage to receptors is proposed. Additionally application cases are presented for the effectiveness of protection wall in the LPG filling station. The study shows that the protection wall can effectively reduce the death probabilities of receptors located behind the wall in cases of the jet fires and the vapor cloud explosions.

A Study on the Damage of Flame caused by the Vapor Cloud Explosion in LPG Filling Station (LPG충전소에서 증기운폭발에 의한 화염의 피해에 관한 연구)

  • Leem, Sa-Hwan;Huh, Yong-Jeong
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.53-60
    • /
    • 2010
  • LPG(Liquefied Petroleum Gas) vehicles in metropolitan area are being applied to improve air quality and have been proven effective for the reduction of air pollutant. In addition, LPG demand is growing rapidly as an environmentally friendly energy source and its gas station is also increasing every year. Consequently, this study tries to find out the influence of flame caused by the VCE(Vapor Cloud Explosion) in filling station on the adjacent combustibles and people by simulating relevant quantity of TNT. In addition, the damage estimation was conducted by using API regulations. If the scale of the radiation heat is known by calculating the distance of flame influence from the explosion site, the damage from the site can be easily estimated. And the accident damage was estimated by applying the influence on the adjacent structures and people into the PROBIT model. According to the probit analyze, the spot which is 30m away from the flame has 100% of the damage probability by the first-degree burn, 99.2% of the damage probability by the second-degree burn and 93.4% of the death probability by the fire.

A Study on the Quantitative Analysis for Explosion of LPG Storage Tank (LPG 저장탱크의 폭발에 대한 정량적 영향평가에 관한 연구)

  • Leem, Sa Hwan;Huh, Yong Jeong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2013
  • The influence of the over-pressure caused by Explosion in gas station was calculated by using the Hopkinson's scaling law and injury effect by accident to buildings and human bodies was estimated by applying the probit model. As a result, the injury estimation was conducted by using the probit model for leakage 10% of 20ton storage tank. The separate distances from LPG station for building(damage) and human(lung hemorrhage to death) are 260 and 30 meters, respectively.

A Study on the Minimum Safe Separation Distance from LPG Filling Station (액화석유가스 충전소의 안전거리에 관한 연구)

  • Jo Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.2 s.7
    • /
    • pp.24-33
    • /
    • 1999
  • The minimum safe separation distances from LPG filling station was discussed in this work based on the accident data from 1987 to 1998 in south korea, the initial damage of accident, and standards of countries. The safety distances are adequate to reduce ignition probability by released gas and provide space for implementation of emergency response after ignition. Therefore, the distances are related to the distance to LFL(Lower Flammable Limit) and the length of jet fire to prevent accident escalation. The range of the distance was suggested in this work to make standard with considering economic, culture, and safe guards.

  • PDF

A Study on Site to Build Hydrogen Multi Energy Filling Station in Domestic LPG Station (국내 LPG 충전소 내 수소 융·복합충전소 구축 가능 부지 연구)

  • PARK, JIWON;HUH, YUNSIL;KANG, SEUNGKYU
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.6
    • /
    • pp.642-648
    • /
    • 2017
  • The use of fossil is causing enviromental all over the world. So hydrogen energy is attracting attention as one of the alternative. The government announced that 30% of the air pollution is because of the Internal Combustion Engine Vehicle. In addition, they plans to reduce Internal Combustion Engine Vehicles by 2030 and increase (electric vehicles, EV) or (fuel cell vehicle, FCV). The FCV is evaluated as a next-generation green car because it has a long driving distance and short charging time. However, the hydrogen industry is not able to expand due to the lack of refueling infrastrucutre. This paper predicts the site of hydrogen refueling stations for the expansion of the hydrogen industry and proposes a method to supply hydrogen multi energy filling stations.

Analysis of Operation Data Monitoring for LPG-Hydrogen Multi-Fueling Station (LPG-수소복합충전소 운영데이터 모니터링 분석)

  • Park, Songhyun;Kim, Donghwan;Ku, Yeonjin;Kim, Piljong;Huh, Yunsil
    • Journal of Energy Engineering
    • /
    • v.28 no.4
    • /
    • pp.1-7
    • /
    • 2019
  • In response to the recent increase in demand for hydrogen stations, the Ministry of Trade and Industry has enacted and promulgated special notifications to enable the installation of hydrogen stations in the form of the combined complex in existing automotive fuel supply facilities such as LPG, CNG, and gas stations. Hydrogen multi energy filling stations haven't been operated yet in Korea till the establishment of special standards, so it is necessary create special standards by considering all Korean environmental characteristics such as four seasons and daily crossings. In this study, we collected and analyzed the charging data of Ulsan LPG-Hydrogen Multi Fueling Station installed for the first time in Korea. The data are hourly temperature and pressure data from compressors, storage vessels and dispensers. We used the data collected for a year, including the highest temperature and the lowest temperature in Ulsan to compare seasonal characteristics. As a result, it was found that the change of the outside temperature affects the initial temperature of the vehicle's container of the hydrogen car, which finally affects the charging time and the charging speed of the vehicle. There was no effect on vehicle containers because the limit temperature suggested by the Korean Hydrogen Station Standard(KGS FP217) and the US Filling Protocol(SAE J2601) was not exceeded.