• Title/Summary/Keyword: Lat. X-ray

Search Result 19, Processing Time 0.029 seconds

Diagnosis of Location and Size of Lesions using Chest X-ray Image (X-선 영상을 이용한 암의 위치 및 크기 진단)

  • Jung-Min, Son;Byung-Ju, Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.167-173
    • /
    • 2023
  • X-ray general radiography is the simplest and most important one to get a lot of information. Nevertheless, current x-ray general radiography does not observation in-depth observation. Information about the anatomy of the human body and changes in disease in x-ray general radiography can be obtained but it is difficult to determine the size and shape of the actual lesion due to the disadvantage of expanding the image. In this study, PA and LAT images were acquired and cancer magnification was calculated in the images by measuring the distance of cancer samples. By adjusting the magnification the actual cancer length and thickness were measured and compared with the CT image and the actual cancer sample size. After the PA and LAT images of the inserted 6.0 mm cancer sample were obtained and the magnification was corrected, the length was 5.9 mm and the thickness was 6.1 mm. This value was measured similarly to the actual. The problem of obtaining the magnification that needs to know the actual length from the detector to the cancer sample was secured by obtaining the magnification through PA and LAT images and it is possible to accurately measure the cancer sample size. X-ray general radiography may provide useful information in situations where CT imaging is difficult.

The Study of Effectiveness of Wooden Pillow and Comparison Evaluation of diagnosis method on Straightening of Cervical Curvature Patient (교통사고 후 한방병원에 입원한 일자목증후군 환자를 대상으로 한 진단방법의 비교 평가 및 경침사용의 유효성 연구)

  • Lee, Chiho;Jeon, Donghwi;Lee, Eunjung;Oh, Minseok
    • Journal of Haehwa Medicine
    • /
    • v.24 no.2
    • /
    • pp.1-16
    • /
    • 2016
  • Objectives : This study was designed to evaluate various tools including C-spine X-ray for estimating cervical curvature and identify the effect of wooden pillow on patients diagnosed with straightening of cervical curvature. Methods : This study was carried out on 51 subjects who were encountered traffic accident suffering cervical pain and diagnosed with straightening of cervical curvature by X-ray. 51 subjects were divided into wooden pillow(experimental) group and conservative therapy(control) group. Visual analogue scale, neck disability index and lateral pictures were used and compared after treatment. C-spine AP., Lat. X-ray were used on admission day to calculate cervical curvature and scoliosis by various ways. Results : 4 different measurements of cervical curvature didn't show common results. Both wooden pillow(experimental) group and conservative therapy(control) group showed significant improvement in the visual analogue scale(VAS) and neck disability index(NDI) after hospital treatment. Comparison between center line pictured by lateral view and C-spine Lat. pictured by X-ray showed significant difference in cervical curvature. Lateral deviation of cervical vertebra showed lengthened distance between mastoid process and spinous process of C7. Conclusion : As a result of this research, I found out that various tools for calculating cervical lordosis could derive different results and C-spine AP., Lat X-ray could cause artificial cervical lordosis. According to visual analogue scale(VAS) and neck disability index(NDI) wooden pillow was not effective to reduce pain & disability caused by straightening of cervical curvature. Futhermore, correction effect of straightening of cervical curvature and scoliosis by wooden pillow was weak.

Comparison of Machine Learning Classification Models for the Development of Simulators for General X-ray Examination Education (일반엑스선검사 교육용 시뮬레이터 개발을 위한 기계학습 분류모델 비교)

  • Lee, In-Ja;Park, Chae-Yeon;Lee, Jun-Ho
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.111-116
    • /
    • 2022
  • In this study, the applicability of machine learning for the development of a simulator for general X-ray examination education is evaluated. To this end, k-nearest neighbor(kNN), support vector machine(SVM) and neural network(NN) classification models are analyzed to present the most suitable model by analyzing the results. Image data was obtained by taking 100 photos each corresponding to Posterior anterior(PA), Posterior anterior oblique(Obl), Lateral(Lat), Fan lateral(Fan lat). 70% of the acquired 400 image data were used as training sets for learning machine learning models and 30% were used as test sets for evaluation. and prediction model was constructed for right-handed PA, Obl, Lat, Fan lat image classification. Based on the data set, after constructing the classification model using the kNN, SVM, and NN models, each model was compared through an error matrix. As a result of the evaluation, the accuracy of kNN was 0.967 area under curve(AUC) was 0.993, and the accuracy of SVM was 0.992 AUC was 1.000. The accuracy of NN was 0.992 and AUC was 0.999, which was slightly lower in kNN, but all three models recorded high accuracy and AUC. In this study, right-handed PA, Obl, Lat, Fan lat images were classified and predicted using the machine learning classification models, kNN, SVM, and NN models. The prediction showed that SVM and NN were the same at 0.992, and AUC was similar at 1.000 and 0.999, indicating that both models showed high predictive power and were applicable to educational simulators.

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

High Energy Observational Investigations of Supernova Remnants and their Interactions with Surroundings

  • Hui, Chung-Yue
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.3
    • /
    • pp.127-132
    • /
    • 2013
  • Here we review the effort of Fermi Asian Network (FAN) in exploring the supernova remnants (SNRs) with state-of-art high energy observatories, including Fermi Gamma-ray Space Telescope and Chandra X-ray Observatory, in the period of 2011- 2012. Utilizing the data from Fermi LAT, we have discovered the GeV emission at the position of the Galactic SNR Kes 17 which provides evidence for the hadronic acceleration. Our study also sheds light on the propagation of cosmic rays from their acceleration site to the intersteller medium. We have also launched an identification campaign of SNR candidates in the Milky Way, in which a new SNR G308.3-1.4 have been uncovered with our Chandra observation. Apart from the remnant, we have also discovered an associated compact object at its center. The multiwavelength properties of this X-ray source suggest it can possibly be the compact binary that survived a supernova explosion.

Exploring the Extra Component in the Gamma-ray Emission of the New Redback Candidate 3FGL J2039.6-5618

  • Ng, Cho-Wing;Cheng, Kwong-Sang;Takata, Jumpei
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.2
    • /
    • pp.93-99
    • /
    • 2016
  • A redback system is a binary system composed of a pulsar and a main sequence star. The inverse Compton (IC) scattering between the stellar soft photons and the relativistic pulsar wind will generate orbital-modulating GeV photons. We look for these IC emissions from redback systems. A multi-wavelength observation of an unassociated gamma-ray source, 3FGL J2039.6-5618, by Salvetti et al. (2015) detected an orbital modulation with a period of 0.2 days in both X-ray and optical cases. They suggested 3FGL J2039.6-5618 to be a new redback candidate. We analyzed the gamma-ray emission of 3FGL J2039.6-5618 using the data from the Fermi large area telescope (Fermi-LAT) and obtained the spectrum in different orbital phases. We propose that the spectrum has orbital dependency and estimate the characteristic energy of the IC emission from the stellar-pulsar wind interaction.

Pulsed γ-ray emission from magnetar 1E 2259+586

  • Wu, Jason Hung Kit;Hui, Chung Yue;Huang, Regina Hsiu Hui;Kong, Albert Kwok Hing;Cheng, Kwong Sang;Takata, Jumpei;Tam, Pak Hin Thomas;Wu, Eric Man Ho;Liu, Joe
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.2
    • /
    • pp.83-85
    • /
    • 2013
  • Anomalous X-ray pulsars (AXPs) are thought to be magnetars which are young isolated neutron stars with extremely strong magnetic fields of > $10^{14}$ Gauss. Their tremendous magnetic fields inferred from the spin parameters provide a huge energy reservoir to power the observed X-ray emission. High-energy emission above 0.3 MeV has never been detected despite intensive search. Here, we present the possible Fermi Large Area Telescope (LAT) detection of ${\gamma}$-ray pulsations above 200 MeV from the AXP, 1E 2259+586, which puts the current theoretical models of ${\gamma}$-ray emission mechanisms of magnetars into challenge. We speculate that the high-energy ${\gamma}$-rays originate from the outer magnetosphere of the magnetar.

Testing the Consistency of Unified Scheme of Seyfert Galaxies

  • Iyida, Evaristus U.;Eya, Innocent O.;Eze, Christian I.
    • Journal of Astronomy and Space Sciences
    • /
    • v.39 no.2
    • /
    • pp.43-50
    • /
    • 2022
  • The unified scheme of Seyfert galaxies hypothesizes that the observed differences between the two categories of Seyfert galaxies, type 1 (Sy1) and type 2 (Sy2) are merely due to the difference in the orientation of the toroidal shape of the obscuring material in the active galactic nuclei. We used in this paper, a sample consisting of 120 Seyfert galaxies at 1.40 × 109 Hz in radio, 2.52 × 1017 Hz in X-ray and 2.52 × 1023 Hz in γ-ray luminosities observed by the Fermi Large Area Telescope (Fermi-LAT) in order to test the unified scheme of radio-quiet Seyfert galaxies. Our main results are as follows: (i) We found that the distributions of multiwave luminosities (Lradio, LX-ray, and Lγ-ray) of Sy1 and Sy2 are completely overlapped with up to a factor of 4. The principal component analysis result reveals that Sy1 and Sy2 also occupy the same parameter spaces, which agrees with the notion that Sy1 and Sy2 are the same class objects. A Kolmogorov-Smirnov test performed on the sub-samples indicates that the null hypothesis (both are from the same population) cannot be rejected with chance probability p ~ 0 and separation distance K = 0.013. This result supports the fact that there is no statistical difference between the properties of Sy1 and Sy2 (ii) We found that the coefficient of the best-fit linear regression equation between the common properties of Sy1 and Sy2 is significant (r > 0.50) which plausibly implies that Sy1 and Sy2 are the same type of objects observed at different viewing angle.

Phases and phase Equilibria of the Pt-Sb System (백금-안티모니 계의 식평구 및 화합흉에 대한 연구)

  • 김원사
    • Korean Journal of Crystallography
    • /
    • v.4 no.1
    • /
    • pp.18-24
    • /
    • 1993
  • The phase diagram of the Pt-Sb system was reinvestigated, using the conventional sealedcapsule technique. The identification of phases present in the reaction products was made by reflected light microscopy, X-ray diffraction and electron microprobe analysis. The existence of compounds, Pt5Sb, Pt3Sb, Pt3Sb2, PtSb and PtSb5 was confirmed. A new phase, Pt5Sb with a composition of 83at% Pt and tetragonal structure of the lattice parameters a=3.948(3), c=16.85(1)A, was found. The X-ray powder data of Ptsb may be indexable on a tetragonal cell with a=3.9455(7), c=16.959(5)A. PtSb is stoichiometric up to 800t and becomes Pt-deficient as much as lat% at 1000t. Solid solubility limits of Sb in Pt were determined to be 7.5,10.0 and 6.1at% at 1000˚,800˚ and 600˚ , respectively. The earlier reported Pts Sbf was not found in this study. The liquidus curve between the Ptsb2 and Sb phases was revised.

  • PDF

The consideration about exact set-up with stereotactic radiosurgery for lung cancer. (폐암 환자의 전신 정위적 방사선 수술시 정확한 SET UP에 대한 고찰)

  • Seo, Dong-Rin;Hong, Dong-Gi;Kwon, Kyung-Tea;Park, Kwang-Ho;Kim, Jung-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.1-8
    • /
    • 2004
  • Purpose : What confirm a patient's set-up precisely is an important factor in stereotactic radiosurgery Especially, the tumor is moved by respiration in case of lung cancer. So it is difficult to confirm a exact location by L-gram or EPID. I will verify a exact patient's set-up about this sort of problem by verification system(exactrac 3.0) Materials and Methods : The patient that had lung cancer operated on stereotactic radiosurgery is composed of 6 people. The 5 patients use an ABC tool and 1 patient doesn't use it. I got such a patient's L-gram and EPID image by Body frame(elekta, sweden), compared Ant. image with Lat. one, and then confirmed a set-up. I fused DRR image of CT and X-ray image of Verification system(exactrac 3.0) 3 dimensional, analyzed the coordinate value(vertical, longitudinal, lateral), and then confirmed a difference of existing method. Results : In case of L-gram and EPID, we judge an exact of the patient's set-up subjectively, and on we could treat the patient with radiation. As a result of using Verification system(exactrac 3.0), coordinate value(vertical, longitudinal, lateral) of patient's set-up was comprised within 5mm. We could estimate a difference of the coordinate value visually and objectively. Consequently, Verification system(exactrac 3.0) was useful in judging an exact patient's set-up. Conclusion : In case of Verification system(exactrac 3.0), we can confirm an exact patient's set-up at any time whenever, However, there are several kinds of the demerit. First, it is a complex process of confirmation than the existing process. Second, thickness of CT scan slice is within 3mm. The last, X-ray image has to have shown itself clearly. If we solve this problem. stereotactic radiosurgery will be useful in treating patients why we can confirm an exact patient's positioning easily.

  • PDF