• Title/Summary/Keyword: Lenses

Search Result 933, Processing Time 0.028 seconds

Analysis add Comparison of the Performance of Optical Collimator by Lenses (렌즈에 따른 광콜리메이터 성능 비교 분석)

  • 선화영;최두선;제태진;최기봉;김동식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.132-136
    • /
    • 2002
  • Optical collimating lenses are play a role as maintenance parallel light and as a kind of optical collimating lens, there is Ball lenses, GRIN-rod lenses, spherical lenses and aspherical lenses etc. but recently GRIN lens has monopolized a market. The performance of optical collimator depended on the coupling efficiency. In this paper, we were compared and analyzed to be measured values of coupling efficiency with respect to optical working distance using GRIN rod lenses and spherical lenses. In the case of GRIN lenses with a beam size of 420 ${\mu}{\textrm}{m}$, the minimum coupling efficiency was obtained to a measured value of 0.15 ㏈ and in the case of spherical lenses was obtained to a measured value of 0.12 ㏈ on the same condition. In results, we found that a performance of spherical lenses be better as compared with a that of GRIN lens.

  • PDF

The study on the understanding and contentment of training of using soft contact lenses (연성 콘택트렌즈 관리교육의 이해도·만족도 조사)

  • Shin, Jang Cheol
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.13-18
    • /
    • 2002
  • This study conducts the soft contact lenses user's understanding and contentment of training while at the place of purchase. It is based on a questionnaire to the residents in and outside the Masan area, aged between ten to thirty, who have worn soft contact lenses. It examines the training of using contact lenses and lens-care products, the period of wearing lenses, exchanging lenses, sterilizing lenses, side effects of using lenses or the periodic examination, and the understanding and contentment of the users during the training. The results of the research are as below : First, the understanding of training of using lenses, using lens-care products, the period of wearing lenses, exchanging lenses was high, but it was low for the training of sterilizing lenses, side effects of wearing lenses or the periodic examination. Second, the contentment of training of using lenses, lens-care products, the period of wearing lenses, exchanging lenses was high, but low for the training of sterilizing lenses, side effects of wearing lenses or the periodic examination. Therefore, the trainer of the contact lenses must easily and sincerely explain sterilizing lenses, the side effects of using lenses and the periodic examination, cheek with the users, and provide guidelines so as to improve the understanding and the contentment of training of using contact lenses.

  • PDF

Analysis of Absorbance for Tinted Dye Absorbed into Tinted Lenses by Spectrophotometric Method (분광광도법에 의한 칼라 렌즈 내 염색제에 대한 흡광도 분석)

  • Choi, Eun-Jung;Jung, Ju-Hyun
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.704-708
    • /
    • 2009
  • We studied absorbance of tinted dye absorbed into tinted lenses by Spectrophotometric method. Used lenses and tinted dye were CR-39 plastic optical lenses and Ons & $Lavas^{(R)}$ Blue, respectively. Absorbance values of tinted dye absorbed into tinted lenses were obtained from the differences of absorbance values between tinted lenses and CR-30 lenses. Average concentrations of tinted dye absorbed into tinted lenses were obtained from the mass differences between tinted lenses and CR-30 lenses. The relationship between absorbance and average concentration for tinted dye absorbed into tinted lenses was also confirmed to follow Beer’s law. The absorption coefficient calculated from the tangent of the calibration curve was determined to be a=0.983 $Lg^{-1}cm^{-1}$.

A Review: All Solid-state Electroactive Polymer-based Tunable Lens (고체 전기활성 고분자 기반 가변 렌즈의 연구동향)

  • Shin, Eun-Jae;Ko, Hyun-U;Kim, Sang-Youn
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.1
    • /
    • pp.41-48
    • /
    • 2021
  • In this paper, we review papers which report to the all solid-state electroactive polymer-based tunable lens. Since electroactive polymer-based tunable lenses change their focal length by responding to electric stimuli, it can be minimized the size and weight of optical modules. Thus, it has been received attention in the robot, mobile device and display industry. The all solid-state electroactive polymer-based tunable lenses can be classified into two categories depending on the classification of materials: ionic electroactive polymer-based lenses and non-ionic electroactive polymer-based lenses. Most of the ionic electroactive polymer-based tunable lenses are fabricated with ionic polymer-metal composite. So, the ionic electroactive polymer-based tunable lenses can be operated under low electric voltage. But small force, slow recovery time and environmental limitation for operation has been pointed to the disadvantage of the lenses. The non-ionic electroactive polymer-based tunable lenses are classified again into two categories: dielectric polymer-based tunable lenses and polyvinylchloride gel-based tunable lenses. The advantage of the dielectric polymer-based tunable lenses is fast response to electric stimuli. But the essential flexible electrodes degrade performance of the lens. Polyvinylchloride gel-based tunable lens has reported impressive performance without flexible electrodes.

Clinical fitting of soft contact lenses

  • Cho-BOptom, Pauline
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.81-91
    • /
    • 2004
  • The use of soft contact lenses for myopia correction is increasing in many countries. It is therefore important for contact lens practitioners to be properly educated in fitting these lenses. Before fitting lenses, it is important to consider the factors and procedures related to soft contact lens fitting, indications and contraindications of fitting soft contact lenses. In this article, the functions and activities involved in preliminary, fitting and delivery consultations will be presented.

  • PDF

The Evaluation of Property of Colored Contact Lenses (칼라콘택트렌즈의 물성적 특성 평가)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.119-126
    • /
    • 2005
  • The purpose of this study was analyzed to compare on the physical characters of two companies of color contact lenses. Artificial tear solution was used for measuring the rate of protein deposits and wettability. The surface roughness of lenses was measured by SEM(scanning electron microscope, Japan) and AFM(atomic force microscope, MultimodeTM, USA). As a results, The color contact lenses was not different from general soft contact lenses in a respect of other properties. However, the colored contact lenses showed a severe crack on the surface under SEM observation. There was no irregularity on the surface of the colored contact lenses in AFM photograph. The dyes were deposited in inside of lenses by microscope observation.

  • PDF

Contrast Sensitivity and Glare with Spherical and Toric Soft Contact Lenses in Low-astigmatic Eyes (구면과 토릭 소프트 렌즈로 교정한 약도 난시안의 대비감도와 눈부심)

  • Lee, Min-Ah;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Purpose: The purpose of this study is to compare the visual performance by contrast sensitivity (CS) and disability glare (DG) in low astigmatic eyes corrected with toric soft lenses and other optical corrections. Methods: Twenty university students with myopia (-1.00 to -6.50D Sph. with astigmatism up to 1.50 cyl) were enrolled and corrected by five different methods: 1) soft toric lenses; 2) spherical soft contact lenses; 3) RGP lenses; 4) best spectacle corrected visual acuity; 5) spherical equivalent spectacles. All subjects had corrected vision acuity of 20/20 or better. Contrast sensitivity and disability glare were measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView Functional Vision Analysis software at photopic or mesopic conditions with glare. Results: At photopic condition, best corrected spectacle wearers had the highest monocular contrast sensitivity at all spatial frequency followed by soft toric lenses, RGP lenses, spherical equivalent spectacles, and spherical soft contact lenses. However, all of them were in normal contrast sensitivity value at photopic condition. At mesopic condition with glare, toric soft lenses were the highest and followed by RGP lenses, spherical equivalent spectacles, best spectacle corrected visual acuity and spherical soft contact lenses. It was observed that spherical soft contact lens wearers demonstrated lower range than normal contrast sensitivity value at mesopic condition with glare. Conclusion: Toric soft lenses gave better visual performance than spherical soft lenses in low astigmatic eyes. Subjects requiring the use of contact lenses under mesophic conditions could benefit from toric soft lenses.

  • PDF

Comparison of In Vitro Lipid Deposition and Change of Optical Characteristics on Daily Disposable Lenses (1-day) and 3-days Lenses Over 3 days (3-days lenses와 daily disposable lenses(1-day)의 착용 시간 별 지방 침착량 및 광학적 특성 변화의 비교)

  • Song, Sun Jung;Lee, Su Yeon;Kim, Ki Hong;Chu, Byoung Sun
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.2
    • /
    • pp.67-73
    • /
    • 2020
  • The study aimed to investigate in vitro lipid deposition of oleic acid, oleic acid methyl ester and cholesterol on a daily disposable (1-day lenses) and 3-days lenses over 3 days and changes of optical characteristics is also investigated. Artificial tear solutions were prepared to simulate actual tear compositions. Two types of contact lenses (1-day lenses (Senofilcon A) and 3-days lenses (silicone tripolymer)) were soaked in the artificial tear solutions within an incubator at 37 ℃ with 150 rpm for 8, 16, 24 hours. Lipid deposition (oleic acid, oleic acid methyl ester and cholesterol) were measured using high performance liquid chromatography (HPLC) instrument. In addition, measurements of oxygen transmissibility, light transmittance and observation of lens surface were conducted. The amount of lipid deposition on the 1-day lenses were 127.55 ㎍/lens for Day 1, 302.96 ㎍/lens, for Day 2, and 353.30 ㎍/lens for Day 3. The 3-days lenses were 46.22 ㎍/lens for Day 1, 66.07 ㎍/lens for Day 2, and 67.45 ㎍/lens for Day 3. Oxygen transmissibility were 81×10-9(cm/sec)(ml O2/ml×mmHg)(Baseline) and 48×10-9(cm/sec)(ml O2/ml×mmHg) (Day 3) for the 1-day lenses, it were 13.23×10-9(cm/sec)(ml O2/ml×mmHg)(Baseline) and 9.6×10-9(cm/sec)(ml O2/ml×mmHg) (Day 3) for the 3-days lenses. Transmittance of each lenses were 97.21% (Baseline) and 94.25% (Day 3) for the 1-day lenses, 97.65% (Baseline) and 95.15% (Day 3) for the 3-days lenses. Observation of surface deposition indicated greatest deposition for the 3-days lenses type on Day 3. Lipid deposition for both lens types increased by day and was greater for the 1-day lenses type. Surface deposition appeared to differ as it was greatest for the 3 days lens type, which may suggest other deposits such as protein may be present.

Microbe Pollution Condition on Soft Contact Lenses (소프트 콘택트렌즈에서의 미생물 오염양상)

  • Han, Sun-Hee;Park, Sung-Min;Yu, Tae-Shick
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.313-321
    • /
    • 2005
  • To know the pollution level concerning the microbes contamination condition in soft contact lenses, 2 experiments were operated with different methods. Firs experiment, we observed lenses surfaces through a scanning electronic microscope after pollution sort contact lenses with the suspensions of Staphylococcus aureus, Pseudomonas aeruginosa and Entrobacter aerogenes which can be major bacteria causing keratitis as wearing on soft contact lenses. As 1 hour after pollution with the soft contact lenses, we observed that many bacteria adhered to the lenses, and the pollution condition got worse with passing time increase(2, 4, 6, 12, and 24 hours, respectively). At 12 hours lapse of polluting soft contact lenses with P. aeruginosa, some bacteria adhered to the lenses. And as 24 hours lapsed after pollution soft lenses with E. aerogenes, bacteria adhered to them, and atypical substance was observed some of the surface of lenses. Second experiment, we observed the microbe pollution condition in soft contact lenses by let 21 people in twenties(men & women), who doesn't eye disorders, wear soft contact lenses during 4 hours. As the result, many kinds of bacterium and fungus were observed, and especially, the bacteria could be identified with their colors and the shapes of colony, so we found that single type, two types, and three types of bacteria adhered to their lenses.

  • PDF

The Design of Telecentric Lenses and Fly-eye Lenses by Utilizing fθ Formula (fθ 공식을 활용한 텔레센트릭 렌즈 및 플라이아이 렌즈의 설계)

  • Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.1
    • /
    • pp.9-16
    • /
    • 2013
  • We try to find the generalized structural equation that gives a perspective understanding for telecentric lenses through paraxial optical algebraic equations and preconditions from a highly experienced design sense. The equation is named the $f{\theta}$ formula and this formula is applied to single lenses, double Gauss lenses, Cooke triplet lenses and the compound lens composed of a Cooke triplet lens and a double Gauss lens step by step. And this formula is also applied to single fly-eye lenses plus a telecentric lens and double fly-eye lenses plus a telecentric lens in sequence. As a result, we can confirm that this $f{\theta}$ formula leads to intuitive optical design with a structural understanding for telecentric lens systems.