• Title/Summary/Keyword: Lifting Device

Search Result 67, Processing Time 0.031 seconds

The test methods of Lifting performance and Environmental resistance tests using power assist device for a fireman to rescue humans (인명구조용 소방대원 근력지원장치의 양중성능 및 내환경 시험 방법)

  • Lee, Minsu;Park, Chan;Lee, Seonmin;Lee, Dongeun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.358-365
    • /
    • 2017
  • As the damage caused by disasters increases rapidly around the world, it is necessary to develop the technology for equipment to reduce human injury. Therefore in the support of fire safety and 119 rescue and rescue technology research and development project, in the "Development of a power assist device for a fireman to rescue humans(2015 ~ 2018)" for life saving restoration, we are developing equipment that satisfies the lifting performance considering the disaster environment and the disaster response scenario(Amount of load over 100 kg, height of over 1 m, height over middle 60 cm, speed over 0.2 m/s). In this study, we propose a lifting performance and environmental test method to evaluate the usefulness of the power-assisted device and analyze and verify detailed specifications of the device through dynamics analysis of the lifting performance test. This study suggests that the proposed test method can be applied practically to evaluate whether a stable performance of a power-assisted device is achieved.

Structural Safety Analysis of Lifting Device for Spent Fuel Dual-purpose Metal Cask (사용후핵연료 금속겸용용기 인양장비의 구조 안전성 해석)

  • Moon, Tae-Chul;Baeg, Chang-Yeal;Yun, Si-Tae;Choi, Byung-Il;Jung, In-Su
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.4
    • /
    • pp.299-314
    • /
    • 2014
  • A lifting device is used to deal with transport cask for the transportation of spent fuels from nuclear power plants. This study performed theoretical analysis and numerical simulation to evaluate the structural integrity of the lifting device based on Nuclear Safety and Security Commission(NSSC) Notice No.2013-27 and US 10CFR Part 71 ${\S}71.45$. The results of theoretical analysis showed that the maximum stresses of all components were below the allowable values. This result confirmed that the lifting device was structurally safe during operation. The results of finite element analysis also showed that it was evaluated to satisfy the design criteria bothyielding and ultimate condition. All components have been shown to ensure the structural safety due to sufficient safety margins. In other words, the safety factor was 3 or more for the yielding condition and was 5 or more for the ultimate condition.

Implementation of ICT-based Underwater Communication Monitoring Device for Underwater Lifting (수중구조를 위한 ICT 기반 수중통신 모니터링 장치 구현)

  • Yoon, Jong-Hwa;Kang, Sang-iL;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.396-400
    • /
    • 2022
  • In this study, an ICT-based underwater communication monitoring device for underwater structures is implemented based on lifting fixture that transport human bodies found on the seabed to sea level. The lifting fixture is packaged with a retback, sideback, and cartridge that injects air. Monitoring systems are developed in a mobile manner in a portable structure. The underwater ultrasonic sensor signal is supplied using a USB port, and the O/S consists of Linux. For the underwater communication dong test, a measurement test was conducted in real time from 6m to 40m in depth on the east coast. The ultrasonic sound sensor is converted to 2,400 bps to verify the transmission error according to the duality. The communication speed of sensor to monitoring is 115,200 bps, and the speed of communication from controller to receiver is 2,400 bps. In the commercialization stage of the lifting device, it is easy to develop a low-end type and the compatibility is wide.

The Study on Designing and Making Power Lifting Wheelchair using Mecanum Wheels (메카넘 바퀴를 적용한 리프팅 휠체어의 설계 및 제작에 관한 연구)

  • Jo, Jang-Hyen;Hwang, Byung-Jun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.2
    • /
    • pp.211-218
    • /
    • 2011
  • We reported the design, prototype, test drive, and mechanical & electrical engineering analyses of a power-lifting wheelchair using mecanum wheels. Mecanum wheels enable translational and rotational movement of the device in any direction on the ground. The power-lifting capability enables the seated individual to reach the standing height of a non-disabled individual. This mecanum wheelchair is fully controlled by the joystick attached to the armrest. The motion of the wheelchair and lifting action of the seat were studied using statics and dynamics. We believe this mecanum wheelchair is a prime candidate for commercial production.

Implementation of Human Positioning Monitoring Device for Underwater Safety (수중안전을 위한 인체 위치추적 모니터링 장치 구현)

  • Jong-Hwa Yoon;Dal-Hwan Yoon
    • Journal of IKEEE
    • /
    • v.27 no.3
    • /
    • pp.225-233
    • /
    • 2023
  • This paper implements a system that monitors human body lifting information in the event of a marine accident. The monitoring system performs ultrasonic communication through a lifting device controller that transmits underwater environment information, and LoRa communication is performed on the water to provide GPS information within 10 km to the control center or mother ship. The underwater lifting controller transmits pneumatic sensor, gyro sensor, and temperature sensor information. In an environment where the underwater conditions increase by one atmosphere of water pressure every 10m in depth, and the amount of air in the instrument decreases by half compared to land, a model of a 60kg underwater mannequin is used. Using one 38g CO2 cartridge in the lifting appliance SMB(Surface Maker Buoy), carry out a lifting appliance discharge test based on the water level rise conditions within 10 sec. Underwater communication constitutes a data transmission environment using a 2,400-bps ultrasonic sensor from a depth of 40m to 100m. The monitoring signal aims to ensure the safety and safe human structure of the salvage worker by providing water depth, water temperature, and directional angle to rescue workers on the surface of the water.

Z-Clutching: Interaction Technique for Navigating 3D Virtual Environment Using a Generic Haptic Device

  • Song, Deok-Jae;Kim, Seokyeol;Park, Jinah
    • Journal of Computing Science and Engineering
    • /
    • v.10 no.1
    • /
    • pp.32-38
    • /
    • 2016
  • Navigating a large 3D virtual environment using a generic haptic device can be challenging since the haptic device is usually bounded by its own physical workspace. On the other hand, mouse interaction easily handles the situation with a clutching mechanism-simply lifting the mouse and repositioning its location in the physical space. Since the haptic device is used for both input and output at the same time, in many cases, its freedom needs to be limited in order to accommodate such a situation. In this paper, we propose a new mechanism called Z-Clutching for 3D navigation of a virtual environment by using only the haptic device without any interruption or sacrifice in the given degrees of freedom of the device's handle. We define the clutching state which is set by pulling the haptic handle back into space. It acts similarly to lifting the mouse off the desk. In this way, the user naturally feels the haptic feedback based on the depth (z-direction), while manipulating the haptic device and moving the view as desired. We conducted a user study to evaluate the proposed interaction technique, and the results are promising in terms of the usefulness of the proposed mechanism.

Design and Prototyping of Lifting Devices for Manhole Cover using Structural Analysis and 3D Printing (3D 프린팅과 구조해석을 이용한 맨홀의 부양장치 설계 및 제작)

  • Lee, Hyoungwook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.648-654
    • /
    • 2018
  • In order to maintain manholes installed on the road, the manhole should be easy to open and close. Manhole covers under harsh conditions require that they can be lifted when attempting to open the manhole because the frame and cover are stuck and difficult to open and close. In this study, the design of a lifting mechanism was carried out to improve and integrate the locking type manhole. The mechanism of the locking manhole is that when the bolt located at the center is turned, the hub connected with the bolt descends, and the hook connected to the hub is rotated. The end of the hook is hooked to the manhole frame. The auxiliary device was installed on the hook so that the manhole cover can be lifted. The structure was designed to endure about 300kg of lifting force based on 70% of the yield stress of the hook to perform lifting function. The shape design was performed through the structural analysis using the finite element method. First, the basic design was performed with the simplified 2-dimensional model and the attachment position and shape were designed through the 3-dimensional model. In order to find out the structural problems of the designed shape, the scale downed model was fabricated through 3D printing and confirmed that the lifting function worked. Finally, it was confirmed that both the locking and the average lifting of about 6.1 mm can be done by applying the lifting mechanism through the machining and applying it to the existing locking manhole.

A Study on the Measurement of Contact Force of Pantograph on High Speed Train

  • Seo Sung-Il;Cho Yong-Hyun;Mok Jin-Yong;Park Choon-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.10
    • /
    • pp.1548-1556
    • /
    • 2006
  • Appropriate contact force is required for the pantograph on the high speed train to collect current from the catenery system without separation. However, at high speed, large aerodynamic lifting force is generated by the contact plate and the body of pantograph, which may cause wear of the contact wire. In this study, to confirm the interface performance of the pantograph on Korea High Speed Train, a method to measure the contact force of the pantograph was proposed and the related measuring system was developed. The forces acting on the pantograph were clarified and a practical procedure to estimate the forces was proposed. A special device was invented and applied to measure the aerodynamic lifting force. Measured contact forces were displayed by the developed system and evaluated based on the criteria.

Quantitative study of acupuncture manipulation of lifting-thrusting using an needle insertion-measurement system in phantom tissue

  • Lee, Soo-Yoon;Son, Young-Nam;Choi, In-Hwa;Shin, Kyung-Min;Kim, Kap-Sung;Lee, Seung-Deok
    • The Journal of Korean Medicine
    • /
    • v.35 no.4
    • /
    • pp.74-82
    • /
    • 2014
  • Objectives: Quantification, objectification, and standardization of lifting-thrusting manipulation are important issues in traditional Chinese medicine (TCM). The purpose of this study was to quantitatively investigate the difference in the amount of stimulation according to range and frequency among parameters of lifting-thrusting manipulation with the use of a needle insertion-measurement system. Methods: For quantification of lifting-thrusting manipulation, an acupuncture needle insertion-measurement system was used in phantom tissue. The motor and force sensors of the needle insertion device were connected to the control software. This enabled operation of the lifting-thrusting manipulation and measurement of the acupuncture needle force. The measurement of the acupuncture needle force according to various frequencies (0.25, 0.50, 0.75, and 1 Hz) and ranges of movement (2, 4, 6, 8, and 10 mm) was repeated 10 times. Results: At a constant frequency of movement, acupuncture needle force according to range of movement (2, 4, 6, 8, and 10 mm) increased with increasing range of movement (p < 0.05). At a constant range of movement, acupuncture needle force according to frequency of movement (0.25, 0.50, 0.75, and 1.0 Hz) increased with increasing frequency of movement (p < 0.05). Conclusion: In this study, we conducted a quantitative comparison of the amount of stimulation according to range and frequency, the main parameters of lifting-thrusting manipulation, by using an acupuncture needle insertion-measurement system. Future studies on various manipulations and parameters are warranted to quantify and objectify the amounts of stimulation by acupuncture manipulation.

Operator Modeling and Design of Fuzzy Controller for a Wire-Driven Heavy Material Lifting System (와이어 구동식 중량물 권양 시스템을 위한 퍼지제어기 설계 및 작업자 모델링)

  • Song, Bo-Wei;Seo, Hyun-Duk;Lee, Yun-Jung
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.5
    • /
    • pp.436-443
    • /
    • 2013
  • This paper presents design methods of a fuzzy controller and an operator model for a wire-driven heavy material lifting system helping human workers. The wire-driven heavy material lifting system is a kind of human-assistive systems in which a human is involved in the control loop. Thus, human's control characteristics and requirement of reducing worker's force to lift a heavy material are considered in the design process of the proposed fuzzy controller. An automatic weight measurement algorithm during the early stage of lifting is also introduced. Finally, the effectiveness and performance of the proposed system are proved by experiments.