Effects of Aerosol Hygroscopicity on Fine Particle Mass Concentration and Light Extinction Coefficient at Seoul and Gosan in Korea

  • Choi, Eun-Kyung;Kim, Yong-Pyo
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.1
    • /
    • pp.55-61
    • /
    • 2010
  • The sensitivity of aerosol light extinction coefficient to the aerosol chemical composition change is estimated by (1) calculating the aerosol water content and chemical concentrations by a gas/particle equilibrium model and (2) calculating the aerosol light extinction coefficient by a Mie theory based optical model. The major chemical species are total (gas and particle phase) sulfuric acid, total nitric acid, and total ammonia which are based on the measurement data at Seoul and Gosan. At Seoul, since there were enough ammonia to neutralize both total sulfuric acid and total nitric acid, the dry ionic concentration is most sensitive to the variation of the total nitric acid level, while the total mass concentration (ionic concentration plus water content) and thus, the aerosol light extinction coefficient are primarily determined by the total sulfuric acid. At Gosan, since the concentration of ambient sulfuric acid was the highest among the inorganic species, sulfate salts determined aerosol hygroscopicity. Thus, both ionic and total mass concentration, and resultant aerosol light extinction coefficient are primarily determined by the sulfuric acid level.

A Study on the Concentration and Light Extinction of Atmospheric Aerosol in Seoul (서울 대기 에어로솔의 농도와 광소산에 관한 연구)

  • 김필수;오미석;김의훈
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.3
    • /
    • pp.227-234
    • /
    • 1991
  • This study deals with concentration and light extinction of atmospheric aerosol in Seoul. From the measured aerosol size distribution for particle diameter ranging from 0.01 $\mum \sim 1.0 \mum$, extinction coefficient is calculated using the Mie theory. The results show that the diurnal variation of aerosol concentration, in general, reveals the lowest concentration in early morning and afternoon, while the highest at about 8 O'clock owing to the heavy traffic and accumulation of air pollution in the low atmosphere. However, aerosol concentration and extinction coefficient on April 7 give low values due to the advective wind. On the other hand, high aerosol concentration and extinction coefficenat are recorded on April 10 although solar radiation is weak. From the distribution of extinction coefficient we can find that aerosol particles of 0.1 $\mum \sim 1.0 \mum$ in diameter are highly effective on light extinction.

  • PDF

Comparison between a Light-Scattering and a Light-Extinction Methods for the Study on Soot Yielding Characteristics of an Electric Cable Fire (전선 매연 생성 특성 연구를 위한 광산란법-광소멸법의 비교)

  • Cho, Sang-Moon;Lee, Min-Jung;Kim, Nam-Il
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.38-43
    • /
    • 2008
  • Significant portion of the fire accident is caused by some troubles in electric circuits. To prevent the fire induced by those electric trouble, some indications of electric fire need to be suitably detected at the first stage of the fire development. With this background, the characteristics of soot yielding of electric cables have been investigated using a light extinction method. In this study, a light scattering method was compared with the light extinction method. A slot-type premixed-flame combustor was traversed to bum three types of electric cables by compulsion, then the mass decrease rate and the soot densities were measured. According to the experimental results, the light scattering method is preferred to the light extinction method when the soot yield ratio is relatively small. Thus the former method is more suitable to detect the occurrence of an electric fire in a power distributer box.

Improvement of Field Calibration of a Transmissometer for Visibility Measurement

  • Kim Kyung W.;Kim Young J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.E2
    • /
    • pp.49-56
    • /
    • 2005
  • A long-path transmissometer is one of the optical instruments widely used to measure atmospheric light extinction coefficient without enclosing a light beam and perturbing aerosols. Over the past two decades, a number of measurements have been carried out using the long-path transmissometer manufactured by OPTEC, Inc. Calibration of the transmissometer should be performed when any component of the transmissometer system is interchanged or installation condition is changed. For a better calibration of the transmissometer, application of a modified calibration method for the existing neutral density (ND)-filter method was recommended for the computation of the atmospheric transmittance using model MODTRAN 4 in this study. It was revealed that the measured light extinction coefficient from the transmissometer which was calibrated using the existing ND-filter method could be overestimated due to the assumption of the atmospheric transmittance suggested by OPTEC, Inc. The uncertainty of the measured light extinction coefficient from the transmissometer calibrated based on the modified ND-filter method was calculated to be approximately $13Mm^{-1}$.

Physico-Chemical Characteristics of Visibility Impairment by Airborne Pollen (공중화분에 의한 시정장애 현상의 물리적 및 화학적 특성 규명)

  • Kim, Kyung-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.863-875
    • /
    • 2006
  • Intensive visibility monitoring was conducted to investigate physical and chemical characteristics of visibility impairment by airborne pollen. Light attenuation coefficients were optically measured by a transmissometer, a nephelometer, and an aethalometer. Elemental, ionic, and carbonaceous species were chemically analyzed on the filters collected by $PM_{2.5}$ and $PM_{10}$ samplers. Aerosol size distribution was analyzed using a cascade impactor during airborne pollen period. Airborne pollen count was calculated using a scanning electron microscope. Airborne pollen was emitted into the atmosphere in springtime and funker degraded visibility through its scattering and absorbing the light. Average light extinction coefficient was measured to be $211{\pm}36Mm^{-1}$ when airborne pollen was not observed. But it increased to $459{\pm}267Mm^{-1}$ during the airborne pollen period due to increase of average $PM_{2.5}$ and $PM_{10}$ mass concentration and relative humidity and airborne pollen count concentration for $PM_{10}$, which were measured to be $46.5{\pm}29.1{\mu}g\;m^{-3},\;97.0{\pm}41.7{\mu}g\;m^{-3},\;54.1{\pm}11.6%$, and $68.2{\pm}89.7m^{-3}$, respectively. Average light extinction efficiencies for $PM_{2.5}$ and $PM_{10}$ were calculated to be $5.9{\pm}0.9$ and $4.5{\pm}0.8m^2 g^{-1}$ during the airborne pollen period. Light extinction efficiency for $PM_{10}$ increased further than that for $PM_{2.5}$. The average light extinction budget by airborne pollen was estimated to be about 24% out of the average measured light extinction coefficient during the airborne pollen period.

A Comparative Study on the Measurement of Smoke from Diesel Vehicle on Chassis-dynamometer using Reflection Photo and Light Extinction Method (차대 동력계에서의 디젤 차량의 매연 측정을 위한 여지 반사식 및 광투과식 측정법의 비교 연구)

  • Kim, Ju-Chul;Lee, Choong-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.6
    • /
    • pp.13-19
    • /
    • 2007
  • Diesel car's smoke measurement equipment and method were investigated based on the exhaust gas regulations. Reflection photo method and light extinction method for measuring smoke were compared under conditions of both no load mode and Lug-down 3 mode. Free acceleration mode at no load condition was used for regular inspection of diesel car, and Lug-down 3 mode was used for fine inspection of the diesel car. A correlation between no load mode and Lug-down 3 mode was investigated in this research. The smoke measured with reflection photo method was 1.5${\sim}$2 times higher than that of light extinction method The correlation coefficient between reflection photo method and light extinction method for measuring smoke was 0.83, which shows comparatively high correlation between the two methods for measuring smoke in diesel engines.

Physico-Chemical Characteristics of Visibility Impairment in a National Park Area (국립공원 지역 시정장애 현상의 물리.화학적 특성)

  • Kim, Kyung-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.4
    • /
    • pp.325-338
    • /
    • 2009
  • National parks provide recreation, health, and science to human being. The provision of beautiful landscape view of the national park improves an economic and social phase of a nation. However, visibility impairment frequently occurred in the national park area of Gyeongju. The purpose of this study is to investigate the physical and the chemical characteristics of visibility reduction observed at the national park area of Gyeongju. Optical, chemical, meteorological characteristics and scenic monitoring were performed at the visibility monitoring station of Gyeongju University located at the Seoak section of Gyeongju national park from April 28 to May 9, 2008. Light extinction, light scattering, and light absorption coefficients were continuously measured using a transmissometer, a nephelometer, and an aethalometer, respectively. In order to investigate the impact of aerosol chemistry on visibility impairment, size-resolved aerosols were collected at intervals of 2-hour (from 8 A.M. to 6 P.M.) and 14-hour (from 6 P.M. to 8 A.M.) interval each sampling day. The average light extinction coefficient and the average visual range were measured to be $270{\pm}135\;Mm^{-1}$ and $14.5{\pm}6.3\;km$ during the intensive monitoring period, respectively. It was revealed that sulfate particle was the largest contributor to the light extinction under hazy condition. Organic mass accounted for about 26% of the average light extinction. The mass extinction efficiencies for $PM_{1.0}$, $PM_{2.5}$, and $PM_{10}$ were estimated to be 9.0, 4.7, and $2.7\;m^2\;g^{-1}$ under the consideration of water growth function of hygroscopic aerosols, respectively.

A new method for mapping visible-near infrared light levels in Fruit

  • Fraser, Daniel G.;Jordan, Robert B.;Kunnemeyer, Rainer;Mcglone, V. Andrew
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1128-1128
    • /
    • 2001
  • We have developed a probe for measuring the light levels inside illuminated fruit. The probe has minimal effect on the light levels being measured and enables the sampling of the light flux at any point within the fruit. We present experimental light extinction rates within apple, nashi, kiwifruit, and mandarin fruit. Moving from the illuminated side to the far side of the fruit, the extinction level follows an initial power law decay as the light diffuses into the fruit then reduces to an exponential decay through the rest of the fruit. Significant variations in the rates of light extinction are found in the core, skin and differing flesh regions. Monte Carlo simulations of the light distribution in fruit, which use scattering and absorption coefficients for the diffusely scattering tissue, and boundary conditions for the skin effects, produce results that follow the experimental results closely.

  • PDF

The Characteristics of Soot at the Post-Flame Region in Jet Diffusion Flames Added Carbon Dioxide (이산화탄소가 첨가된 제트확산화염 후류에서의 매연 특성)

  • Ji, Jung-Hoon;Lee, Eui-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.9-13
    • /
    • 2010
  • An experimental study for characteristics of soot were conducted at the post-flame region in jet diffusion flames, where carbon dioxide was used as additives in oxidizer stream. Light-extinction method was performed using He-Ne laser with wave length at 632.8nm for the measurement of relative soot density and soot volume fraction with dimensionless extinction coefficient, $K_e$ and mass specific extinction coefficient, ${\sigma}_s$. To increase of resolution, laser light was modified for sheet-form using concave, convex lenses and slit. C/H ratio was introduced for quantitative analysis of soot growth which is expressed by carbonization and dehydrogen. Also transmission electron microscopy(TEM) was used for observation of morphological shape. The results show that the relative soot density in the post-flame region was lower when carbon dioxide was added in oxidizer stream because of reduction of flame temperature.

Uncertainty Analysis of the Optical Smoke Density Measurement through the Doorway in a Compartment Fire (구획화재의 출입구를 통한 광학적 연기밀도 측정의 불확실성 해석)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.75-79
    • /
    • 2013
  • The present study measured the light transmission to quantify the smoke density(smoke mass concentration) through the doorway in a compartment fire and performed the uncertainty analysis to evaluate the reliability of the measurement technique. The optical light extinction method based on Bourguer's law was applied to estimate the smoke density of doorway exhausting smoke flow in upper layer of a compartment for methane gas fires. The measurement uncertainty of the light extinction measurement was evaluated for the light transmittance, path length, and specific mass extinction coefficient and the expanded uncertainty was estimated about 20% with confidence level of 95%. The mean smoke density through the doorway for the methane fire was calculated for quasi-steady fire and the smoke density linearly increased as the GER increased.