• Title/Summary/Keyword: Linear Motion Unit

Search Result 60, Processing Time 0.03 seconds

Development of Monitoring and Diagnosis System for Linear Motion Unit (직선 운동 유닛의 감시 및 진단 시스템 개발)

  • Huang, Jian;Kim, Hwa-Young;Ahn, Jung-Hwan
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.635-636
    • /
    • 2012
  • In the present work, investigations by high frequency resonance technique for diagnosis of defect frequencies of linear motion unit are reported. Raw vibration signature of the moving parts at different speeds of operation has been demodulated. Envelope detected spectrum is analyzed to evaluate various defect frequencies and their energy levels. Experimentally evaluated frequencies are compared with theoretically determined defect frequencies. These frequency values and their energy levels are used to monitor intrinsic condition of linear motion unit as well as to establish severity of existing/developed defects on the LM guide and inside the LM block. Relative comparisons of linear motion units of the same type are made at various operating speeds under identical conditions of operation on the basis of identified defect frequencies and severity of defects.

  • PDF

Development of plane Motion Accuracy Measurement Unit of NC Lathe (NC 선반의 정면 운동정도 측정장치의 개발)

  • 김영석;한지희;정정표;윤원주;송인석
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.7
    • /
    • pp.101-106
    • /
    • 2004
  • Measurements of linear motion accuracy for one axis of NC lathe have achieved with laser interferometer system, but measurement of plane motion accuracy for two axes on zx-plane of NC lathe have not achieved with the above system. Therefore in this study, measuring unit system is organized using two optical linear scales in order to acquire error. data during of plane motion of ATC(Automatic Tool Change.) of NC lathe by reading zx-plane coordinates. Two optical linear scales of measuring unit are fixed on zx-plane of NC lathe, and moving part of the scales are fixed to the ATC and then error motion data of z, x-coordinates of the ATC are received from the scales through the PC counter card inserted in computer at constant time intervals using tick pulses coming out from computer. And then, error motion data files acquired from measuring are saved in computer memory and the aspect of plane motion are modeled to plots, and range of the error data, means. average deviations, and standard deviations etc. are calculated by means of statistical treatments using computer programs.

Floated Wafer Motion Modeling of Clean Tube system

  • Shin, Dong-Hun;Yun, Chung-Yong;Jeong, Kyoo-Sik;Choi, Chul-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1264-1268
    • /
    • 2004
  • This paper presents a wafer motion modeling of the transfer unit and the control unit in the clean tube system, which was developed as a means for transferring the air-floated wafers inside the closed tube filled with the super clean airs. The motion in the transfer unit is modeled as a mass-spring-damper system where the recovering force by air jets issued from the perforated plate is modeled as a linear spring. The motion in the control unit is also modeled as another mass-spring-damper system, but in two dimensional systems. Experiments with a clean tube system built for 12-inch wafers show the validity of the presented force and motion models.

  • PDF

Development of Rehabilitation Medicine Device for Compound Joint Motion (복합관절 운동용 재활의료기기)

  • 정성훈;유범상;김남균;박상민;송문상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.704-708
    • /
    • 2004
  • The RMD(Rehabilitation Medicine Device) with CJM(Compound Joint Motion) is the lower limb unit muscular strengthening promotion rehabilitation medicine device for patients of joint orthopedic operation or the deficient elder of ability to walk, the handicapped. Since the products for the rehabilitation medicine device have limited to the simplicity linear motion, those do not give efficient the lower unit muscular strengthening effects. This device which was under the development gives to exercise of hip joint and knee joint with user's selection at once, get out of the simplicity linear motion. Also it will be contributed to a field of rehabilitation medicine and a mobility aid technology of the deficient elders of ability to walk, the handicapped.

  • PDF

A Development of Single Action Press Robot (프레스 단동로봇의 개발)

  • 허성창;황병복
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.261-264
    • /
    • 1997
  • A single action press robot, which consists of a driving unit, rotator, up-down feed base and feed bar, is developed and applied for the press automation. The driving unit is made up with a face cam and blade cam, which have a phase angle. The feeding system consists of a double speed-up apparatus and linear motion guides, and has a fast motion characteristics. A horizontal feeding speed of the feed bar is increased twice by the double speed-up apparatus. The driving mechanism could be simplified due to the speed-up of the feeding unit.

  • PDF

Improvement of Motion Accuracy Using Transfer Function in Linear Motion Bearing Guide (전달함수를 이용한 직선베어링 안내면의 운동정밀도 향상)

  • Kim, Kyung-Ho;Park, Chun-Hong;Lee, Hu-Sang;Kim, Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.6
    • /
    • pp.77-85
    • /
    • 2002
  • An analysis method which calculates corrective machining information for improving the motion accuracy of linear motion guide Is proposed in this paper. The method is composed of two algorithms. One is the algorithm fur prediction of the motion errors from rail form error. The other is the algorithm for prediction of rail form error from the motion errors of table. Transfer function is utilized in each algorithm, which represents the ratio of bearing reaction force variation to unit magnitude of spatial frequencies of raid from error. As the corrective machining information is acquired from the measured motion errors of table, the method has a merit not to measure rail form error directly. Validity of the method is verified both theoretically and experimentally. By applying the method, linear motion error of test equipment is reduced from 5.97$\mu$m to 0.58$\mu$m, and reduced from 32.78arcsec to 6.21 arcsec in case of angular motion error. From the results, it is confirmed that the method is very effective to improve the motion accuracy of linear motion guide.

Wafer Motion Modeling of Transfer Unit in Clean Tube System (클린 튜브 시스템 이송 유닛의 웨이퍼 운동 역학 모델링)

  • 신동헌;정규식;윤정용
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.3
    • /
    • pp.66-73
    • /
    • 2004
  • This paper presents wafer motion modeling of transfer unit in clean tube system, which was developed as a means for transferring the air-floated wafers inside the closed tube filled with the super clean airs. When the wafer is transferred in x direction with an initial velocity the motion along x direction can be modeled as a simple decaying motion due to viscous friction of the fluid. But, the motion in y direction is modeled as a mass-spring-damper system where the recovering force by air jets issued from the perforated is modeled as a linear spring. Experiments with a clean tube system built fur 12 wafer show the validity of the presented force and motion models.

Organization of Circular Motion Accuracy Measuring System of NC Lathe using Linear Scales (리니어 스케일을 이용한 NC 선반의 원 운동정도 측정 시스템의 구성)

  • Kim Young Seuk;Kim Jae Yeol;Kim Jong Kwan;Han Ji Hee;Jung Jung Pyo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.5
    • /
    • pp.1-6
    • /
    • 2004
  • Measurements of circular motion accuracy of NC lathe have achieved with ball bar systems proposed by Bryan, but the ball bar systems have ifluenced on the measuring data by way of the accuracy of the balls and the contacts of balls and bar seats. Therefore in this study, error data during of circular motion of ATC(Automatic Tool Changer) of NC lathe will be acquired by reading zx plane coordinates using two optical linear scales. Two optical linear scales of measuring unit are fixed on z-x plane of NC lathe, and the moving part is fixed to ATC and then is made to receive data of coordinates of the ATC at constant time intervals using tick pulses comming out from computer. And then, error data files of radial direction of circular motion are calculated with the data read, and the aspect of circular motion are modeled to plots, and are analysed by means of statistical treatments of circularity, means, standard deviations etc.

Wafer Motion Control of Clean Tube System (클린튜브 시스템의 웨이퍼 운동 제어)

  • 신동헌;최철환;정규식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.475-481
    • /
    • 2004
  • This paper presents a force model of the clean tube system, which was developed as a means of transferring air-floated wafers inside a closed tube filled with super clean air. The recovering force from the holes for floating wafers is modeled as a linear spring and thus the wafers motion is modeled as a mass-spring-damper system. The propelling forces are modeled as linear along with the wafer location. The paper also proposes a control method to emit and stop a wafer at the center of a control unit. It reveals the minimum value of the propelling force to leave from the control unit. In order to stop the wafer, it utilizes the exact time when the wafer arrives at the position to activate the propelling force. Experiments with the clean tube system built for the 12 inch wafer shows the validity of the proposed model and the algorithm.

The Correlation of the Pressure of Biofeedback Unit and Lumbopelvic Motion During Straight Leg Raising in Healthy Subjects (정상인에서 수동적인 뻗은다리올림 시 생체되먹임 장치의 압력과 허리골반 움직임의 상관관계)

  • Jung, Do-young
    • Physical Therapy Korea
    • /
    • v.25 no.3
    • /
    • pp.12-18
    • /
    • 2018
  • Background: Passive straight leg raising (PSLR) is the common clinical test to measure of hamstring muscle length. Hip flexion angle contributes to change the lumbopelvic rotation during PSLR. Pressure biofeedback unit (PBU) is commonly used to detect lumbopelvic movement during lower limb movements. Thus, there may be the relationship between pressure of PBU and lumbopelvic motion during PSLR. Objects: The objective of this study was to determine the relationship between pressure of PBU and lumbopelvic motion during PSLR. Methods: Thirty two subjects participated in this study. A three-dimensional motion analysis system were used to measure the lumbopelvic angle during PSLR, while recording the pressure of PBU according to angle of PSLR by 10 degree increments. Pearson product moment correlations and linear regression analysis were used to describe the relationship between variables. Results: The results showed that there was a significant relationship between the lumbopelvic and angle of PSLR (Pearson's r=.83, p<.05), between the pressure of PBU and angle of PSLR (Pearson's r=.75, p<.05), and between lumbopelvic motion and pressure of PUB (Pearson's r=.83, p<.05). Linear regression equation using lumbopevic angle as an independent factor was as follows: Pressure of PBU = 47.35 + (2.55 ${\times}$ angle of lumbopelvic motion) ($R^2=.69$, p<.05). Conclusion: Results of the present study indicate that pressure of PBU can be used to indirectly detect the amounts of lumbobevic motion during muscle length test or stretching of hamstring.