• Title/Summary/Keyword: Lobe curve

Search Result 39, Processing Time 0.056 seconds

Lobe Curve Characteristic Analysis of Resistance Spot Welding for Sheet Combination of 780MPa Steel Sheet Using Simulation (시뮬레이션을 이용한 780MPa급 강재의 판재 조합에 따른 저항 점 용접의 로브곡선 특성 분석)

  • Son, Chang-Seok;Park, Young Whan
    • Journal of Welding and Joining
    • /
    • v.30 no.6
    • /
    • pp.68-73
    • /
    • 2012
  • Nowadays, car manufacturers tried to improve automotive fuel efficiency, and applied many high strength steels such as AHSS or UHSS to car bodies. Therefore, the number of steel combinations for the resistance spot welding are dramatically increased and the need for weldability evaluation of these combinations are also required. In this study, we suggest the lobe curve using FEM simulations for DP780 steel with 1.0t, 1.4t. The lobe curves which could expressed weldablity and optimal welding condition were obtained according to 6 steel combinations. There were two combinations for same steel sheet which were DP780 1.0t, DP780 1.4t. Dissimilar steel sheet combination with different thickness was 1.0t and 1.4t of DP780. Different steel combinations were DP780 1.0t and SPRC440 1.0t, and DP780 1.0t and DP590 1.0t. Finally dissimilar combinations was and DP780 1.0t and DP590 1.4t. The trend of low boundary and high boundary variation of lobe curve were analyzed with a viewpoint of the contact resistance and the heat input.

Effect of Lobe Shape Variations on the Performance of Roots-type Supercharger (Roots형 과급기 로브 형상 변화가 성능에 미치는 영향)

  • 김윤제;정찰기
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.6
    • /
    • pp.101-110
    • /
    • 2000
  • A Computer program is developed for creation of a new lobe shaper for Roots-type supercharger. Numerical analyses are preformed for the flowfields in the pocket volumes formed by various lobe shapes. The governing equations for the two-dimensional, turbulent, operational processes in the housing are discretized by the control volume approach that insures the conservative characteristics to be satisfied in the calculation domain, and they are solved by a modified SIMPLE algorithm. Numerical results show that the effects of secondary flow on the leakage flow rate with the Cassini(B) lobe shape is smaller than that of Cassini(A) rotor. But the pocket volume of Cassine(B) lobe is larger than the other lobe shapes.

  • PDF

Effects of Lobe Shapes on the Performance of Roots-Type Vacuum Pump (로브 형상 변화가 루츠형 진공 펌프 성능에 미치는 영향)

  • Kim, H.-J.;Kim, Youn J.;Hwang, Y.-K.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.2 s.7
    • /
    • pp.50-56
    • /
    • 2000
  • The effects of lobe shapes on the leak flow conductance of Roots-type vacuum pump are studied numerically and experimentally. The modelled lobe shape of Roots-type vacuum pump is two-lobe spur gear. The numerical analyses are performed on leak flows in Roots-type vacuum pump. It is numerically calculated using a 4th-order Runge-Kutta method and is compared with experimental results. Results show that for the case of involute lobe shape the total amount of the leak flow conductance is greater than that of cycloid and Cassini oval lobe shapes.

  • PDF

Diffusion-Weighted Imaging for the Left Hepatic Lobe has Higher Diagnostic Accuracy for Malignant Focal Liver Lesions

  • Han, Xue;Dong, Yin;Xiu, Jian-Jun;Zhang, Jie;Huang, Zhao-Qin;Cai, Shi-Feng;Yuan, Xian-Shun;Liu, Qing-Wei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.15
    • /
    • pp.6155-6160
    • /
    • 2014
  • Background: This study was conducted to investigate whether apparent diffusion coefficient (ADC) measurements by dividing the liver into left and right hepatic lobes may be utilized to improve the accuracy of differential diagnosis of benign and malignant focal liver lesions. Materials and Methods: A total of 269 consecutive patients with 429 focal liver lesions were examined by 3-T magnetic resonance imaging that included diffusion-weighted imaging. For 58 patients with focal liver lesions of the same etiology in left and right hepatic lobes, ADCs of normal liver parenchyma and focal liver lesions were calculated and compared using the paired t-test. For all 269 patients, ADC cutoffs for focal liver lesions and diagnostic accuracy in the left hepatic lobe, right hepatic lobe and whole liver were evaluated by receiver operating characteristic curve analysis. Results: For the group of 58 patients, mean ADCs of normal liver parenchyma and focal liver lesions in the left hepatic lobe were significantly higher than those in the right hepatic lobe. For differentiating malignant lesions from benign lesions in all patients, the sensitivity and specificity were 92.6% and 92.0% in the left hepatic lobe, 94.4% and 94.4% in the right hepatic lobe, and 90.4% and 94.7% in the whole liver, respectively. The area under the curve of the right hepatic lobe, but not the left hepatic lobe, was higher than that of the whole liver. Conclusions: ADCs of normal liver parenchyma and focal liver lesions in the left hepatic lobe were significantly higher than those in the right hepatic lobe. Optimal ADC cutoff for focal liver lesions in the right hepatic lobe, but not in the left hepatic lobe, had higher diagnostic accuracy compared with that in the whole liver.

Characterization of Primary Dynamic Resistance in Resistance Spot Welding (저항 점 용접의 1차 동저항 특성에 관한 연구)

  • 조용준;이세헌;신현일;배경민
    • Journal of Welding and Joining
    • /
    • v.17 no.2
    • /
    • pp.97-103
    • /
    • 1999
  • The dynamic resistance monitoring in primary circuit is one of the important issues. Because in-process and real time quality assurance of resistance spot weld is needed to increase the product reliability. In this study, new dynamic resistance detecting method is proposed as a practical manner of weld quality assurance using instantaneous current and voltage measured at the primary circuit. and also, various patterns of primary dynamic resistance curve are characterized with the macro photograph and the weldability lobe curve. It is found that the primary dynamic resistance patterns are basically similar to those of the secondary, but there is evident advantage such as no extra devices are needed to obtain the quality information and eventually real time feedback control will be possible.

  • PDF

Strength Estimation Model of Resistance Spot Welding in 780MPa Steel Sheet Using Simulation for High Efficiency Car Bodies (시뮬레이션을 이용한 고효율 차체용 780MPa급 강판의 저항 점 용접 강도 예측 모델 개발)

  • Son, Chang-Seok;Park, Young-Whan
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.70-77
    • /
    • 2015
  • Nowadays, car manufacturers applied many high strength steels such AHSS or UHSS to car bodies for weight lightening. Therefore, a variety of applied steel sheet to car bodies increased and the needs of simulation to evaluate weldability also increased in order to reduce the cost and time. In this study, resistance spot welding simulations for DP 780 Steel with 1.0 and 1.4 mm thickness were conducted with respect to lobe curve. 2 regression models to estimate tensile shear strength were suggested and they were second order polynomial regression model and optimized second order regression model. The performance of these models was evaluated in terms of the coefficient of determinant and average error rate.

Design of Elliptical Lobe Type Gear with Involute Profile (타원계 엽형기어의 설계 및 동특성에 관한 연구)

  • 유명섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.4
    • /
    • pp.7-14
    • /
    • 1998
  • Noncircular gears have been used for obtaining the modified anglualr velocity ratio between parallel axes. The elliptical gear, which is a kind of noncircular gears, makes use of ellipse as a pitch curve, and is applied for the measurement of the discharge of liquid. The applications of an elliptical gear are more advantageous than any other mechanism as like a crank-slider linkage or a cam mechanism in view of the accuracy and the reliability to transmit the prescribed motion. In this paper, acceding to the theoretical involute tooth profile, two pairs of the elliptical gears were manufactured by using CNC wire electronic discharge machine. The proper ranges of the operating pressure angle and of module not to generate under cutting are studied on the change of the eccentricity, because it is the eccentricity of the pitch curve that determines most of the characteristics of the elliptical gear and then the vibration analysis is executed for the verification of harmonious rotating.

  • PDF

A Study on Servo DC Resistance Spot Welding of Mg Alloy Sheet(1) (Mg합금판재의 서보가압식 DC점용접에 관한 연구(1))

  • Jung, Sun-Nyeo;Chang, Hee-Seok;Lee, Mok-Young
    • Journal of Welding and Joining
    • /
    • v.27 no.1
    • /
    • pp.102-107
    • /
    • 2009
  • Weldability of Mg alloy was investigated using servo-actuated DC resistance spot welder. Due to its uncommon electrical and mechanical properties, lots of voids and cracks were observed inside nugget with conventional weld schedule. Lobe curve was proposed to clarify proper electrode force and weld current, which guarantee reasonable weld strength and fatigue life. Macro structure of sectioned specimen was examined to count total number of void and crack. Post weld schedule is also proposed to reduce micro victors hardness value of weld zone.

A Study on Sidelobe Reduction Using Kaiser Window in Ultrasonic Imaging System (초음파 영상시스템에서 카이저 윈도우를 이용한 사이드 로브 감축에 관한 연구)

  • Na, Byeong-Yoon;Ahn, Young-Bok;Jeong, Mok-Kun
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.189-200
    • /
    • 1996
  • In this paper, we compared the performance of the Kaiser window with those of others as a weight function of well known anodization technique for regression of side lobe in a field pattern resulted from focusing of transducer array. The Kaiser window is an window providing many types of curve with several variables. In order to compare performance of the Kaiser window as the weight function, anodization results of the previously used Hamming window function and the Matched Gaussian function are compared Result of computer simulation, the pertormance of Kaiser window with $\delta$=0.0025 in side lobe regression was better than that of Hamming window or Matched Gausian function.

  • PDF