• 제목/요약/키워드: Locking plate osteosynthesis

검색결과 12건 처리시간 0.026초

원위 경골 골절에서 전외측 잠김 금속판을 사용한 전외측 최소 침습적 금속판 고정술 (Anterolateral Minimally Invasive Plate Osteosynthesis of Distal Tibial Fractures Using an Anterolateral Locking Plate)

  • 서동환;이환희;한영훈;정재중
    • 대한족부족관절학회지
    • /
    • 제24권1호
    • /
    • pp.19-24
    • /
    • 2020
  • Purpose: Anterolateral minimally invasive plate osteosynthesis (MIPO) was performed to treat patients with distal tibial fractures associated with open fractures or extensive soft tissue injuries, which is limited medial MIPO. The treatment results of the anterolateral MIPO technique were evaluated and analyzed. Materials and Methods: Seventeen patients with distal tibial fractures associated with an open fracture or large bullae formation on the distal tibia medial side were treated with anterolateral MIPO using anterolateral locking plates. Within 24 hours of visiting the emergency room, external fixation was applied, and the medial side wound was managed. After damage control, the anterolateral locking plate was applied using an anterolateral MIPO technique. The union time, nonunion, or malunion were evaluated with regular postoperative radiographs. The ankle range of motion, operative time, blood loss, Iowa score, and wound complications were investigated. Results: Radiological evidence of bony union was obtained in all cases. The mean time to union was 16.7 weeks (12~25 weeks). The mean operation time was 44.0 minutes. Regarding the ankle range of motion, the mean dorsiflexion was 15°, and the mean plantarflexion was 35°. Satisfactory results were obtained in 15 out of 17 cases; five results were classified as excellent, four were good, and six were fair. The mean blood loss was 125.2 mL. Two complications were recorded. Conclusion: In distal tibial fractures with severe medial soft tissue damage caused by high-energy trauma, the staged anterolateral MIPO technique using anterolateral locking plates is a useful alternative treatment to achieving optimal wound care, rapid union with biological fixation, and intra-articular reduction.

원위 대퇴골 골절에 대한 고령 환자군의 치료 결과 비교 -임상적, 방사선학적 비교- (Clinical and Radiological Outcome of Distal Femoral Fracture in Elderly Patient Group)

  • 박희곤;김연준;장호성
    • Journal of Trauma and Injury
    • /
    • 제26권4호
    • /
    • pp.286-290
    • /
    • 2013
  • Purpose: To report the postoperative Clinical and Radiological outcomes following distal femoral fractures in elderly patients compared with young patients. Methods: From March, 1996 to March, 2012, 83 patients who received surgical treatment for fractures of the distal femur were enrolled in this retrospective study. Ages more than 65 was named group A. Group A was 49 cases and mean age is 72.5 year(65~91year). Group B was 49 cases and mean age is 45.7 year(16~61 year). Surgical methods are retrograde IM nail, locking compression plate, cannulated screw and postoperative rehabilitation is no difference between two groups. Clinical results were evaluated using Neer scores, radiographic results and the presence of clinical complications. Results: The mean union period was 18.4(12-40) weeks in group A and 17(10-24) weeks in group B. Neer functional scores are no significant statistical difference between two groups. There are 5 cases metal breakage in group A and 1case in group B. There are 3 cases nonunion in group A and 1 case in group B. Conclusion: In the case of fractures of the distal femur in elderly patients, locking plate using minimally invasive percutaneous periosteal osteosynthesis (MIPPO) technique may be one of the most effective methods and preoperative bone stock evaluation in important.

경골 골간 골절에서의 최소 침습적 금속판 고정술의 이용 3례 (Use of Minimally Invasive Plate Osteosynthesis for Tibial Diaphyseal Fracture in Three Dogs)

  • 허수영;이기창;이해범
    • 한국임상수의학회지
    • /
    • 제29권4호
    • /
    • pp.339-343
    • /
    • 2012
  • 교통사고를 원인으로 3마리의 개가 경골 골간 골절로 내원하였다. 신체검사와 정형외과 검사상 이들 골절은 경골주위에 연조직 손상을 동반한 폐쇄성 골절을 보여 주었다. 방사선검사상 단순 경사골절 (증례1), 복잡 나선형골절 (증례 2), 단순 나선형골절 (증례 3)로 진단되었다. 이들 골절은 수의 절단성 금속판이나 잠김 금속판을 이용하여 최소 침습적 금속판 고정술을 적용하였다. 수술은 성공적으로 이루어지고 7주 (증례 1), 10주 (증례 2) 그리고 8주 (증례3) 후 부작용 없이 골절 치유를 확인할 수 있었다. 수술 후 모든 환자들은 빠른 골치유와 체중 지지를 관찰할 수 있었다. 최소 침습적 금속판 고정술은 수의정형외과영역에서 경골 골간 골절의 유용한 수술법으로 생각된다.

경골 원위부 골절에서 최소 침습적 잠김 압박 금속판 고정술과 함께 최소 절개를 통한 골절편간 지연 나사 고정술을 시행한 경우의 치료 결과 (Clinical Outcomes of Combinations of Locking Compression Plate Fixation through Minimally Invasive Precutaneous Plate Osteosynthesis and Interfragmentary Screw Fixation in Distal Tibia Fracture)

  • 정형진;추지웅
    • 대한족부족관절학회지
    • /
    • 제17권2호
    • /
    • pp.136-142
    • /
    • 2013
  • Purpose: To analyze the outcome of distal tibia fracture treated with the Distal Tibia LCP with combination of interfragmentary screw. Materials and Methods: Between January 2008 and March 2012, data of 34 patients with fracture of distal tibia treated with the Distal Tibia LCP with or without combination of interfragmentary screws were reviewed. There were 17 males and 17 females with an average age of 51.8 years (range, 18~77 years). Radiographic union time and time from surgery until ability to full weight bearing were measured and compared. Callus index was measured as quotient of callus thickness and diameter of corticalis both in AP and sagittal direction. Results: 12 fractures were treated with interfragmentary screws and 22 fractures were treated with bridging plate alone. In interfragmentary fixation group, time to full weight bearing was 14 weeks versus 15.75 weeks without screw. Callus index at bearing was not significantly lesser in patients with screw compated with those without, but callus index difference at posterative 4weeks was sigficant. Radiologic union time was 11.3 weeks in interfragmentary fixation group and 12.58 weeks without screw. Conclusion: The osteosynthesis with the Distal tibia LCP with combination of interfragmentary screw seems to be more stable in postoperative 4weeks than Distal tibia LCP alone, expecting to earlier ROM exercise and rehabilitation.

잠김-압박 금속판을 사용하여 MIPPO 수기를 적용한 원위부 경골 골절의 치료: 관절내 골절과 관절외 골절의 비교 (Treatment of Distal Tibia Fracture using MIPPO Technique with Locking Compression Plate: Comparative Study of the Intraarticular Fracture and Extraarticular Fracture)

  • 정수태;김형수;차승도;유정현;박재형;김주학;정진하
    • 대한족부족관절학회지
    • /
    • 제13권2호
    • /
    • pp.162-168
    • /
    • 2009
  • Purpose: To evaluate the efficiency of the minimally invasive percutaneous plate osteosynthesis (MIPPO) with locking compression plate (LCP) for distal tibial metaphyseal intra-articular fracture compared with extra-articular fracture. Materials and Methods: From February 2006 to June 2008, 21 patients with distal tibia metaphyseal intra-articular fracture and 20 patients with extra-articular fracture were treated operatively by MIPPO technique with LCP and followed for at least one year. In the group with intra-articular fracture, mean age was 48.85 years old and a mean follow-up was 15 months. In the other group with extra-articular fracture, mean age was 52.35 years old and a mean follow-up was 14.5 months. The type of fracture was evaluated using the AO/OTA classification and open-fractures were according to the Gustilo-And gron classification. Radiologic evaluation with fracture healing and tibial alignment, clinical evaluation with Olerud and Molander ankle score and restriction of motion were done for treatment. Results: According to AO/OTA classification, There were 21 type A, 15 type B, 5 type C. Average union time of the intra-articular fracture (type B, C) was 18.7 weeks. Average union time of the extra-articular fracture (type A) was 17.1 weeks. All fractures were healed without malunion. There were no difference of mean restriction angle between intra-articular fracture (ankle dorsiflexion was 3.57 degree, plantar-flexion was 5.95 degree) and extra-articular fracture (ankle dorsiflexion was 3 degree, plantar-flexion was 3.75 degree). There were no difference of Olerud and Molander ankle score between them as a mean score of intra-articular and extra-articular was 89.25, 91.25 each other. As a complication, there were 3 case of skin necrosis, 8 case of discomfortable skin tenting by plate and 1 superficial infection, but could be healed by conservative care. Conclusion: MIPPO technique, combined articular reduction, with LCP of distal tibial metaphyseal fracture was a good method with high functional recovery.

  • PDF

Minimally Invasive Percutaneous Plate Osteosynthesis via a Deltoid-splitting Approach with Strut Allograft for the Treatment of Displaced 3- or 4-part Proximal Humeral Fractures

  • Noh, Young-Min;Kim, Dong Ryul;Kim, Chul-Hong;Lee, Seung Yup
    • Clinics in Shoulder and Elbow
    • /
    • 제21권4호
    • /
    • pp.220-226
    • /
    • 2018
  • Background: This study introduces a surgical technique with good clinical outcome useful in the treatment of osteoporotic displaced 3- or 4-part proximal humeral fractures. Methods: From May 2014 to February 2016, 16 patients with displaced 3- or 4-part proximal humeral fractures were treated by application of a locking plate with an endosteal strut allograft via a deltoid splitting approach with a minimum follow-up of 12 months. The allograft was inserted through a fractured gap of the greater tuberosity to support the humeral head and then fixed by a locking plate with meticulous soft tissue dissection to protect the axillary nerve. Surgical outcomes were evaluated by the American Shoulder and Elbow Surgeons (ASES) and visual analogue scale (VAS) scores, radiological imaging, and clinical examination. Fixation failure on radiographs was defined as a >$5^{\circ}$ loss of neck shaft angle (NSA) compared to that on an immediate postoperative radiograph. Avascular necrosis (AVN) of the humeral head was also evaluated. Results: In all cases, complete union was achieved. The ASES and VAS scores were improved to $85.4{\pm}2.1$ and $3.2{\pm}1.3$, respectively. Twelve patients (75.0%) had greater than a $5^{\circ}$ change in NSA; the average NSA change was $3.8^{\circ}$. Five patients (31.3%) had unsatisfactory ranges of motion exhibiting a <$100^{\circ}$ active forward flexion. No axillary nerve injuries or AVN were observed at the last follow-up. One patient was converted to reverse total arthroplasty due to severe pain and functional deficit. Conclusions: Minimally invasive fixation via a locking compression plate and an endosteal fibula strut allograft in Neer classification 3-or 4-part fractures with severe osteoporosis in elderly patients can achieve good clinical results.

Mechanical evaluation of the use of conventional and locking miniplate/screw systems used in sagittal split ramus osteotomy

  • Santos, Zarina Tatia Barbosa Vieira;Goulart, Douglas Rangel;Sigua-Rodriguez, Eder Alberto;Pozzer, Leandro;Olate, Sergio;Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권2호
    • /
    • pp.77-82
    • /
    • 2017
  • Objectives: The aim of this study was to compare the mechanical resistance of four different osteosyntheses modeled in two different sagittal split ramus osteotomy (SSRO) designs and to determine the linear loading in a universal testing machine. Materials and Methods: An in vitro experiment was conducted with 40 polyurethane hemimandibles. The samples were divided into two groups based on osteotomy design; Group I, right angles between osteotomies and Group II, no right angles between osteotomies. In each group, the hemimandibles were distributed into four subgroups according to the osteosynthesis method, using one 4-hole 2.0 mm conventional or locking plate, with or without one bicortical screw with a length of 12.0 mm (hybrid technique). Each subgroup contained five samples and was subjected to a linear loading test in a universal testing machine. Results: The peak load and peak displacement were compared for statistical significance using PASW Statistics 18.0 (IBM Co., USA). In general, there was no difference between the peak load and peak displacement related to osteotomy design. However, when the subgroups were compared, the osteotomy without right angles offered higher mechanical resistance when one conventional or locking 2.0 mm plate was used. One locking plate with one bicortical screw showed higher mechanical resistance ($162.72{\pm}42.55N$), and these results were statistically significantly compared to one conventional plate with monocortical screws (P=0.016) and one locking plate with monocortical screws (P=0.012). The difference in peak displacement was not statistically significant based on osteotomy design or internal fixation system configuration. Conclusion: The placement of one bicortical screw in the distal region promoted better stabilization of SSRO. The osteotomy design did not influence the mechanical behavior of SSRO when the hybrid technique was applied.

Femoral Periprosthetic Fractures after Total Knee Arthroplasty: New Surgically Oriented Classification with a Review of Current Treatments

  • Rhee, Seung Joon;Cho, Jae Young;Choi, Yoon Young;Sawaguchi, Takeshi;Suh, Jeung Tak
    • Knee surgery & related research
    • /
    • 제30권4호
    • /
    • pp.284-292
    • /
    • 2018
  • Purpose: As the number of total knee arthroplasties (TKAs) increases, the incidence of femoral periprosthetic fractures after TKA is also increasing. This review aimed to suggest a new surgically oriented classification system for femoral periprosthetic fractures. Methods: We investigated the classifications, and current treatment trends for femoral periprosthetic fractures after TKA by means of a thorough review of the relevant literature. Results: Numerous studies reported good results of surgical treatment with modern fixatives including locking compression plates and retrograde intramedullary nails. However, few classifications of femoral periprosthetic fractures reflect the recent developments in surgical treatment. Conclusions: We recommend that surgical management be considered the first-line treatment for femoral periprosthetic fractures after TKA. Our new classification will help in deciding the surgical treatment option for femoral periprosthetic fractures after TKA.

Efficacy of Additive Trans-cuff Augmentation Sutures for Proximal Humeral Fractures Stabilized by Locking Plates in Elderly Patients

  • Cho, Nam Su;Shim, Hee Seok;Lee, Sang Hyeon;Jeon, Jong Wook;Rhee, Yong Girl
    • Clinics in Shoulder and Elbow
    • /
    • 제18권2호
    • /
    • pp.68-74
    • /
    • 2015
  • Background: The purpose of our study was to evaluate the functional and radiologic outcomes of additive augmentation sutures through rotator cuff for proximal humeral fractures stabilized locking plate in elderly patients. Methods: We enrolled 74 patients over the age of 60 years who received internal fixation using locking plates for proximal humeral fractures. Of these, 50 patients had additive augmentation sutures through rotator cuff. The mean age at the time of surgery was 72.1 years (range, 60-89 years), and the mean follow-up period was 17.5 months (range, 12-62 months). The humeral neck-shaft angle and humeral head height were used as radiological markers to assess the effect of additive augmentation sutures through rotator cuff. We allocated the patients who received additive augmentation sutures into group A and those who did not into group B. Results: At the final follow-up, the mean Korean Showlder Society score and Constant scores were $88.96{\pm}12.1$ and $86.6{\pm}11.9$, respectively, in group A and $86.21{\pm}11.8$ and $85.3{\pm}11.7$, respectively, in group B (p=0.368, 0.271). At the final follow-up, the mean loss in humeral neck-shaft angle from the time of immediate postoperative measurement was $1.6^{\circ}$ in group A and $4.8^{\circ}$ in group B, whereas the mean loss in humeral head height was 0.82 mm in group A and 0.52 mm in group B (p=0.029, 0.178). Conclusions: The surgical outcomes of internal fixation using locking plates for proximal humeral fractures were clinically and radiologically good in elderly patients over the age of 60 years without any observable complications. Further, the loss of humeral head shaft angle at the final follow-up from its initial postoperative measurement was significantly smaller in patients who received an additive augmentation suture than in those who did not. Thus, we conclude that augmentation sutures are a beneficial option for elderly patients that clinicians can consider at the time of surgical decision making.

상완골 간부 단순 골절에서 최소 침습적 금속판 골유합술을 이용한 치료 (The Treatment of Humerus Shaft Simple Fracture by MIPO Technique)

  • 고상훈;이선호;조범근
    • Clinics in Shoulder and Elbow
    • /
    • 제16권1호
    • /
    • pp.27-32
    • /
    • 2013
  • 목적: 상완골 간부 단순 골절의 수술적 치료에서 잠김 압박 금속판을 이용한 최소 침습적 금속판 골유합술의 임상적 및 방사선학적 결과를 분석하였다. 대상 및 방법: 2010년 8월부터 2011년 5월까지 상완골 간부 단순 골절 골절에 대해 최소 침습적 금속판 골 유합술을 통해 수술을 시행하고 전향적으로 12개월 이상 추시한 6례의 환자를 대상으로 하였으며, 임상적 및 방사선학적 골유합 기간 및 술 후 관절 운동 범위와 기능을 확인하였다. 결과: 임상적 및 방사선학적 평균 골유합 기간은 각각 7.2주, 8주였다. 술 후 골 정렬에서 전후상 평균 2.8도, 측면상 내반 2도의 변형을 보였다. 술 후 12개월째 견관절 운동 범위는 전방거상 167도, 외회전 50도, 내회전 수위는 흉추 11번이었고, 평균 VAS는 1.2점, KSS는 91.3점, ASES는 26.5점, UCLA 점수는 31.5점이었다. 결론: 상완골 간부 단순 골절의 수술적 치료에서 최소 침습적 금속판 골유합술은 방사선학적 및 기능적으로 우수한 결과를 보였으며 상완골 간부 단순 골절에서 고려해 볼 수 있는 유용한 치료 방법 중 하나라고 생각된다.