• Title/Summary/Keyword: Long discharge gap

Search Result 42, Processing Time 0.025 seconds

A Study of Discharge Characteristics in Xe-Ne Gas Mixture for ac PDP with Long Gap Hump Electrode (Long Gap Hump 전극구조를 가진 ac PDP에서의 Xe-Ne 가스의 방전 특성 연구)

  • Heo, Jong-Cheol;Ok, Jung-Woo;Lee, Don-Kyu;Lee, Hae-June;Lee, Ho-Jun;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.155-159
    • /
    • 2009
  • To increase the luminance and luminous efficacy in the discharge for alternating current plasma display panel (ac PDP), the increment of Xe contents and long discharge gap are necessary. However, the driving voltage and the cost of driving circuit increases in the high Xe contents and long discharge path condition. In this paper, a long gap ITO hump electrode (LGH) model for discharge cells of ac PDP is evaluated in the various Xe contents($5{\sim}20%$). The discharge voltage of LGH structure is lower about 30V than that of ITa reference structure with same main discharge gap. The LGH structure has lower power consumption and higher luminance than those of reference structure, respectively. Also, the luminous efficacy of LGH structure is higher about 20% than that of ITO reference structure in the 20% Xe contents.

The New Structure in AC PDP with Long Discharge Gap for High Luminance and Luminous Efficacy (AC PDP의 휘도 및 효율 향상을 위한 Long Discharge Gap 전극구조 연구)

  • Dong, Eun-Joo;Ok, Jung-Woo;Lee, Don-Kyu;Lee, Hae-June;Lee, Ho-Joon;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.827-832
    • /
    • 2008
  • One of the most important issues in AC PDP is luminance and luminous efficacy. To improve the luminance and luminous efficacy, new sustain electrode structure which contains long discharge gap is necessary. However, it causes a rise of firing voltage. In this experiment, a new structure is proposed in order to solve this problem. To drop the firing voltage, the hump shaped electrode is inserted into the forward area of the main discharge gap. The experimental results show that proposed structures with 160um discharge gap have high firing voltage by 38V, high luminance by 30% and high luminous efficacy by 15% compared with conventional type having 60um discharge gap. In addition, the proposed structure with hump electrode shows lower firing voltage by 24V compared with the test panel with 160um discharge gap which doesn't have hump electrode though they have similar luminous efficacy.

Effect of Protrusion Electrode of the Electro-Optical Characteristics of AC PDP with Long Electrode Gap (Long 전극갭을 가지는 AC PDP의 전기광학적 특성에 미치는 돌기전극의 영향)

  • Heo, Jeong-Eun;Ok, Jung-Woo;Lee, Don-Kyu;Lee, Hae-June;Lee, Ho-Jun;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1422-1428
    • /
    • 2008
  • In the current PDP technology, one of the most important issues in AC PDP is improvement of luminance and luminous efficacy. To improve luminance and luminous efficacy, new cell structure of PDP containing long discharge path is necessary. However, it causes an increment of firing voltage. In order to decrease firing voltage of AC PDP having long discharge gap, the protrusion electrode is proposed. To drop the firing voltage, the protrusion electrode is inserted into the forward area of the main discharge gap. This paper presents measurements of detailed optical and electrical characteristics of AC PDP with protrusion electrodes. The experimental results show that the proposed structure with gap 80um has lower firing voltage to 27V than that of the conventional long gap structure. Moreover, the ICCD(Intensified Charge Coupled Device) images of the proposed structure show quick discharge generation by 0.07usec and longer continuation by 0.05usec than that of the conventional long gap structure. Therefore, the proposed protrusion electrodes have higher luminance by 12.5% than that of the conventional structure, as having no decrement of Luminous efficacy.

Study on Improving the luminous Efficiency of AC PDPs using the Dual Mode Discharge Electrode Structure Having Short-Gap and Long-Gap Discharge (Short-gap과 Long-gap의 이중 방전 전극 구조를 갖는 AC형 플라즈마 표시기의 효율 향상에 대한 연구)

  • 신범재;김태준;이주광;황기웅
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.11
    • /
    • pp.529-535
    • /
    • 2003
  • In this paper, we presents the characteristics of the new electrode structure in an AC Plasma Display Panel(PDP) that can generate dual mode discharges with a combination of short-gap and long-gap discharges. The experiment results show that the discharge voltage of the new electrode structure is mainly determined by short-gap discharge and the luminous efficiency is improved by 20% compared with the conventional electrode structure. The improvement of luminous efficiency is mainly caused by higher VUV generation and broader distribution from Ole ICCD camera measurements.

High Efficacy Plasma Display Utilizing Macro Discharge Cell Structure with Long Electrodes Gap (Long Electrode Gap을 가진 Macro Cell에서의 고효율 PDP 특성 연구)

  • Kim, Min-Tae;Heo, Jun;Kim, Yun-Gi;Kim, Dong-Hyun;Lee, Hea-June;Lee, Ho-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1314-1318
    • /
    • 2012
  • Recently, applications of plasma display to the large public display and transparent display gain much attention. With this background, we report characteristics of opposite electrodes discharge cell with long electrode gap in comparison with conventional co-planar surface discharge. The cell size of test panel is $2950{\mu}m{\times}840{\mu}m$, which corresponds to that of the display having diagonal size of 130" with XGA resolution. Electrode gap of co-planar and opposite electrode structure are $240{\mu}m$ and $500{\mu}m$ respectively. These gap dimensions provide similar driving voltage windows. Experimental results show that opposite discharge provides approximately four fold higher luminous efficacy compared with that of the surface discharge. Resulting efficacy is found to be higher than 19 lm/W in green phosphor with 10 KHz continuous pulse operation.

Effect of Self-Erase Discharge on the Luminous Efficacy of Long Gap AC PDPs

  • Kim, Tae-Jun;Jung, Jae-Chul;Jung, Hae-Yoon;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.585-588
    • /
    • 2007
  • We studied the effect of self-erase discharge on the luminous efficacy of ac PDPs. We observed through discharge current analysis to confirm that the selferase discharge occurred mainly between sustain cathode and address electrode, which have an influence on the luminous efficacy. The amount and timing of the self-erase discharge was varied to observe its effect on the luminous efficacy. It has been found that the luminous efficacy could be improved by the self-erase discharge when it is adjusted to occur right before the main discharge in the small gap structure. In the long gap structure, on the contrary, the luminous efficacy could be increased when the self-erase discharge is suppressed. Also, various waveforms to control self-erase discharge are suggested and tested in the panel experiments.

  • PDF

The Characteristics of the Discharge According to ITO Gap by the CLHS Driving Method in AC PDP (AC PDP에서 CLHS 구동 방법에 의한 ITO Gap에 따른 방전 특성)

  • Shin, Jae-Hwa;Choi, Myung-Gyu;Kim, Gun-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.83-89
    • /
    • 2013
  • In order to reduce the power consumption in international standard IEC62087, the luminance efficiency should be improved at the low discharge load rather than at the high discharge load. Thus, this paper analysed the characteristics of the discharge at the panels with ITO Gap of $65{\mu}m$, $80{\mu}m$, and $100{\mu}m$ in 50-inch PDP with FHD resolution. It was well known that the long gap panel improves the luminance and the luminous efficiency. However, it is very difficult to drive the panel due to high driving voltage. When the normal driving method was applied at the panel with ITO gap of $100{\mu}m$, the phenomenon of the double peak was generated in the sustain period. We confirmed that main factor of the double peak is the self-erasing discharge. When the CLHS driving method was applied at the panel with ITO gap of $100{\mu}m$, the self-erasing discharge was improved in the sustain period. Also, the $V_S$ and $V_A$ minimum voltage of the CLHS driving method decreased about 9V and 12V compared with those of the normal driving method. Moreover, when the CLHS driving method was applied to the panel with ITO gap of $100{\mu}m$, the luminance and the luminous efficiency increased compared with those of the normal driving method. The luminance and the luminous efficiency greatly increased at the low discharge load. The less discharge load, the higher increase rate of the luminance and the luminous efficiency. Especially, the luminous efficiency at ITO gap of $100{\mu}m$ increased about 26.3% at the discharge load of 4% compared with that at ITO gap of $65{\mu}m$.

High Luminous Efficacy AC-PDP with Long Discharge Gap and Grooved Dielectric Structure

  • Lee, Dong-Woo;Choi, Kwang-Yeol;Choi, Sung-Chun;Baek, Dong-Gi;Lim, Jong-Rae;Ahn, Byung-Nam;Park, Won-Bae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.123-126
    • /
    • 2007
  • In this study, a high luminous efficacy AC-PDP panel with long discharge gap and grooved dielectric layer has been studied. By applying this high efficacy concept and optimized driving waveform featuring negative biased sustain, ${\sim}2.6lm/W$ of luminous efficacy was achieved in 42- inch HD panel. Modified fabricating process and new discharge cell structure were investigated to obtain improved uniformity and operating characteristics.

  • PDF

Design of Erase Waveform for Stabilizing Reset Discharge in Mid-gap AC Plasma Display Panels (중간간격을 갖는 교류형 플라즈마 디스플레이 표시기의 소거파형 연구)

  • Yoon, Su-Han;Seo, Jeong-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.993-998
    • /
    • 2011
  • In this paper we suggest new criteria for the classification of the electrode gap between common and scan electrodes. The electrode gap is categorized as a short, middle, and long gap according to the criteria. Among these structures, we focus on the erase waveform of a mid-gap structure. we report an unstable discharge arising from the erase ramp period in a mid-gap structure. Based on the Vt close curve, we analyze the unstable discharge at various conditions. Our analysis reveals that the unstable discharge is ignited between surface electrodes and caused by un-erased wall charges accumulated on the outer edges of electrodes. By reducing the voltage level of the last sustain pulse, the problem is solved.

Embodiment of Low Operating Voltage in Positive Column AC-PDPs

  • Kim, Hyun;Tae, Heung-Sik;Chien, Sung-Il
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.95-98
    • /
    • 2003
  • The positive column discharge characteristics in the long gap (440 ${\mu}m$) are investigated based on the voltage distribution among three electrodes. In particular, the effects of the amplitude and width of the short pulse applied to the address electrode on the positive column discharge characteristics are examined intensively. By proper controlling of the amplitude and width of the address short pulse, it is found that the positive column discharge in the long gap is well constructed. As a result, under the stable static voltage margin condition, the firing and sustaining voltages are as low as those of conventional short gap(60 ${\mu}m$) discharge($V _f=220V$, $V_s=150V$) and the color purity is improved. Moreover, the luminous efficiency increases up to 60% in comparison with the conventional case.

  • PDF