• Title/Summary/Keyword: Low capacitance

Search Result 661, Processing Time 0.033 seconds

Electrode of Low Impedance by Polypyrrole Addition for Supercapacitor (폴리피롤 첨가에 의한 supercapacitor용 저 임피던스 전극)

  • 김경민;장인영;강안수
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2003.11a
    • /
    • pp.343-350
    • /
    • 2003
  • The best Ppy weight ratio was 7 wt% and the optimal electrode composition ratio was 78 : 17 : 5 wt.% of (MSP-20 : BP-20 =1 : 1), (Super P : Ppy =10 : 7) and P(VdF-co-HFP). Implantation of Ppy as the conducting agents have led to superior electrochemical characteristics because of the low of internal resistance and faradaic capacitance. The result of unit cell with Ppy 7 wt% were as follows: 28.02 Fig of specific capacitance, 1.34 Ω of DC-ESR and 0.36 Ω of AC-ESR. Unit cell showed a good stability up to 200 charge-discharge cycles, retaining 82% of their original capacity at 200 cycles. From the analysis of impedance, the electrodes with Ppy 7 wt% showed low ESR, low charge transfer resistance and quick reaction rate. It was inferred that quick charge-discharge was possible. As compared with the specific capacitance (rectangular shape) of CV, it was also concluded that the specific capacitance originated from thecompound phenomena of the faradaic capacitance by oxidation and reduction of Ppy and the non-faradaic capacitance by adsorption-desorption of activated carbon.

  • PDF

A Study on Measuring Electrical Capacitance to Access the Volumetric Water Content of Simulated Soil

  • Rial, W.S.;Han, Y.J.
    • Agricultural and Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.30-37
    • /
    • 2000
  • Wet porous media representing agronomic soil that contains variable water content with variable electrolyte concentration was measured to study the shape of the curves of the electric double layer capacitance versus frequency (from 10 KHz to 10 MHz. This was done in an attempt to find the lowest practical operating frequency for developing low cost dielectric constant soil moisture probes. Cellulose sponge was used as the porous media. A high frequency electronic bridge circuit was developed for measuring the equivalent network parallel resistance and capacitance of porous media. It appears that the effects of the electric double layer component of the total parallel network capacitance essentially disappear at operating frequencies greater than approximately 25 MHz at low electrolyte concentrations but are still important at 50 MHz at higher concentrations. At these frequencies, the double layer capacitance masks the diffusion region capacitance where true water content capacitance values reside. The general shape of the curve of volumetric water content versus porous media dielectric constant is presented, with an empirical equation representing data for this type of curve. It was concluded that the lowest frequency where dielectric constant values which represent true water content information will most likely be found is between 30 and 50 MHz at low electrolyte concentrations but may be above 50 MHz when the total electrolyte concentration is near the upper level required for most mesophyte plant nutrition.

  • PDF

The Tunneling Effect at Semiconductor Interfaces by Hall Measurement (홀측정을 이용한 ZTO 반도체 박막계면에서의 터널링 효과)

  • Oh, Teresa
    • Korean Journal of Materials Research
    • /
    • v.29 no.7
    • /
    • pp.408-411
    • /
    • 2019
  • ZTO/n-Si thin film is produced to investigate tunneling phenomena by interface characteristics by the depletion layer. For diversity of the depletion layer, the thin film of ZTO is heat treated after deposition, and the gpolarization is found to change depending on the heat treatment temperature and capacitance. The higher the heat treatment temperature is, the higher the capacitance is, because more charges are formed, the highest at $150^{\circ}C$. The capacitance decreases at $200^{\circ}C$ ZTO heat treated at $150^{\circ}C$ shows tunneling phenomena, with low non-resistance and reduced charge concentration. When the carrier concentration is low and the resistance is low, the depletion layer has an increased potential barrier, which results in a tunneling phenomenon, which results in an increase in current. However, the ZTO thin film with high charge or high resistance shows a Schottky junction feature. The reason for the great capacitance increase is the increased current due to tunneling in the depletion layer.

Advance Angle Control For Industrial Low Voltage SR Motor (산업용 저전압 SR모터의 진상각 제어)

  • 박대섭;신두진;허욱열
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.232-232
    • /
    • 2000
  • switched reluctance motors and drives are increasingly used in industrial applications due to their robust mechanical structure, low inertia and reduction in the rotor losses. As the motor speed increase turn on angle must be advanced to build up phase current. When C-dump converter is applied to switched reluctance motor, the capacitance of dump C has to have proper value. In this paper advance angle for a switched reluctance motor and capacitance of dump C are investigated. Then proper advance angle and the capacitance of dump-C are propose for the industrial low voltage SR motor.

  • PDF

Multi-layer Structure Method for Manufacturing SiOB with Low Capacitance (낮은 정전용량을 가진 실리콘 광학벤치를 제작하기 위한 적층구조 방법)

  • 김유식;이중희;박문규;장동훈;김태일
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.300-301
    • /
    • 2003
  • As the demand for high frequency(bandwidth) optical module is increased, there is a need for fabricating silicon optical bench(SiOB) with low parasitic impedance. In this paper, we discuss multi-layer structure method for manufacturing SiOB with low capacitance. This structure method decreases the capacitance between the conductive patterns for about 94∼97% compared to the conventional structure without raising the resistivity of silicon, or increasing the thickness of the dielectric film.

  • PDF

Electrochemical Characteristics of Pseudocapacitor Using Aqueous Polymeric Gel Electrolyte (수용성 폴리머 겔 전헤액을 사용한 Pseudocapacitor의 전기화학적 특성)

  • Park, Soo-Gil
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.2
    • /
    • pp.158-160
    • /
    • 2003
  • We have reported to make nanostructured cobalt oxide electrode that have large capacitance over than 400 F/g (specific capacitance) and good cycleability. But, it had serious demerits of low voltage range under 0.5 V and low power density. Therefore, we need to increase voltage range of cobalt oxide electrode. We report here on the electrochemical properties of sol-gel-derived nanoparticulate cobalt xerogel in 1M KOH solution and aqueous polymeric gel electrolyte. In solution electrolyte, cobalt oxide electrode had over 250 F/g capacitance consisted of EDLC and pseudocapacitance. In gel electrolyte, cobalt oxide electrode had around 100 F/g capacitance. This capacitance was only electric double layer capacitance of active surface area. In solution electrolyte, potassium ion as working ion reacted with both of layers easily. However, In gel electrolyte, reacted with only surface-active layer. Itis very hard to reach resistive layer. So, we have studied on pretreatment of electrode to contain working ions easily. We'll report more details.

Design Guidelines for a Capacitive Wireless Power Transfer System with Input/Output Matching Transformers

  • Choi, Sung-Jin
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1656-1663
    • /
    • 2016
  • A capacitive wireless power transfer (C-WPT) system uses an electric field to transmit power through a physical isolation barrier which forms a pair of ac link capacitors between the metal plates. However, the physical dimension and low dielectric constant of the interface medium severely limit the effective link capacitance to a level comparable to the main switch output capacitance of the transmitting circuit, which thus narrows the soft-switching range in the light load condition. Moreover, by fundamental limit analysis, it can be proved that such a low link capacitance increases operating frequency and capacitor voltage stress in the full load condition. In order to handle these problems, this paper investigates optimal design of double matching transformer networks for C-WPT. Using mathematical analysis with fundamental harmonic approximation, a design guideline is presented to avoid unnecessarily high frequency operation, to suppress the voltage stress on the link capacitors, and to achieve wide ZVS range even with low link capacitance. Simulation and hardware implementation are performed on a 5-W prototype system equipped with a 256-pF link capacitance and a 200-pF switch output capacitance. Results show that the proposed scheme ensures zero-voltage-switching from full load to 10% load, and the switching frequency and the link capacitor voltage stress are kept below 250 kHz and 452 V, respectively, in the full load condition.

Response Characteristics for Low Voltage Liquid Crystal Display Employing a Constant Charge Model

  • Kim, Mi-Soon;Huh, Su-Jung;Suh, Duck-Jong;Ahn, Yi-Joon;Lee, Kyung-Jin;Ahn, Seon-Hong;Kim, Kyeong-Hyeon;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.228-230
    • /
    • 2008
  • The response time characteristic of low voltage liquid crystals (LCs) is investigated and a new simulator for low voltage LCs is proposed. In order to enable low voltage operation, it is important to minimize Vth of LCs and variation of pixel voltage caused by dynamic capacitance operation of LC Display. Because dynamic capacitance variation is much larger for low voltage LC operation compared to that of conventional LC material, it is necessary to make a better model for dynamic capacitance operation. A proposed minimizing Vth of LCs and variation of pixel voltage study results through a new constant charge model improve response characteristics for low voltage LCs operation.

  • PDF

Electrochemical Characteristics of Aqueous Polymeric Gel Electrolyte for Supercapaictor (수퍼커패시터용 수용성 고분자 젤 전해질의 전기화학적 특성)

  • Kim, Han-Joo;Ishikawa, Masashi;Morita, Masayuki;Park, Soo-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.93-96
    • /
    • 2001
  • We have reported to make nanostructured cobalt oxide electrode that have large capacitance over than 400F/g (specific capacitance) and good cycleability. But, It had serious demerits of low voltage range under 0.5V and low power density. Therefore, we need to increase voltage range of cobalt oxide electrode. we report here on the electrochemical properties of sol-gel-derived nanoparticulate cobalt xerogel in 1M KOH solution and aqueous polymeric gel electrolyte. In solution electrolyte, cobalt oxide electrode had over than 250F/g capacitance consisted of EDLC and pseudocapacitance. In gel electrolyte, cobalt oxide electrode had around l00F/g capacitance. This capacitance was only surface EDLC. In solution electrolyte, potassium ion as working ion reacted with both of layers easily. However, In gel electrolyte, reacted with only surface-active layer. Its very hard to reach resistive layer. So, we have studied on pretreatment of electrode to contain working ions easily. We'll report more details.

  • PDF

Electrochemical Characteristics of Aqueous Polymeric Gel Electrolyte for Supercapacitor (수퍼커패시터용 수용성 고분자 젤 전해질의 전기화학적 특성)

  • ;Masashi ISHIKAWA;Masayuki MORITA
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.93-96
    • /
    • 2001
  • We have reported to make nanostructured cobalt oxide electrode that have large capacitance over than 400F/g (specific capacitance) and good cycleability. But, It had serious demerits of low voltage range under 0.5V and low power density. Therefore, we need to increase voltage range of cobalt oxide electrode. we report here on the electrochemical properties of sol-gel-derived nanoparticulate cobalt xerogel in 1M KOH solution and aqueous polymeric gel electrolyte. In solution electrolyte, cobalt oxide electrode had over than 250F/g capacitance consisted of EDLC and pseudocapacitance. In gel electrolyte, cobalt oxide electrode had around 100F/g capacitance. This capacitance was only surface EDLC. In solution electrolyte, potassium ion as working ion reacted with both of layers easily. However, In gel electrolyte, reacted with only surface-active layer. Its very hard to reach resistive layer. So, e have studied on pretretmetn of electrode to contain working ions easily. We'll report more details.

  • PDF