• 제목/요약/키워드: Low mode volume

검색결과 87건 처리시간 0.029초

Ultrahuge Light Intensity in the Gap Region of a Bowtie Nanoantenna Coupled to a Low-mode-volume Photonic-crystal Nanocavity

  • Ebadi, Nassibeh;Yadipour, Reza;Baghban, Hamed
    • Current Optics and Photonics
    • /
    • 제2권1호
    • /
    • pp.85-89
    • /
    • 2018
  • This paper presents a new, efficient hybrid photonic-plasmonic structure. The proposed structure efficiently and with very high accuracy combines the resonant mode of a low-mode-volume photonic-crystal nanocavity with a bowtie nanoantenna's plasmonic resonance. The resulting enormous enhancement of light intensity of about $1.1{\times}10^7$ in the gap region of the bowtie nanoantenna, due to the effective optical-resonance combination, is realized by subtle optimization of the nanocavity's optical characteristics. This coupled structure holds great promise for many applications relying on strong confinement and enhancement of optical field in nanoscale volumes, including antennas (communication and information), optical trapping and manipulation, sensors, data storage, nonlinear optics, and lasers.

소아 심장 CT검사 시 Wide Coverage Volume Axial Mode의 유용성 평가 (Evaluation of the Availability of the Wide Coverage Volume Axial Mode in Pediatric Cardiac CT)

  • 박기석;김동현
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.683-689
    • /
    • 2019
  • 소아의 선천적 심장질환 진단을 위해 High Pitch Mode를 사용하여 획득한 소아 심장 CT 영상과 Wide Coverage Volume Axial Mode를 사용하여 획득한 소아 심장 CT 영상으로부터 환자의 피폭선량과 각 영상의 화질을 비교 및 분석하여 Wide Coverage Volume Axial Mode의 유용성을 평가해보고자 한다. 소아 심장 CT 검사 시 High Pitch Mode와 Wide Coverage Volume Axial Mode를 각각 50명 총 100명의 환자를 대상으로 시행하였으며, 각 프로토콜로부터 얻은 영상을 이용하여 환자의 피폭선량을 비교하였다. 각 영상에 ROI를 설정해 SNR과 CNR을 산출하여 영상의 화질을 비교하였다. High Pitch Mode에 비해 Wide Coverage Volume Axial Mode를 사용하여 검사하였을 때 환자의 피폭선량이 13.07% 감소하였고, SNR과 CNR이 향상되었다. Wide Coverage Volume Axial Mode는 고속 회전 스캐너를 이용하여 조사시간을 줄이고, 저선량 기술인 ASi R-V를 통해 High Pitch Mode를 사용했을 때보다 환자의 피폭선량이 감소하고 영상의 화질 또한 향상되는 유용한 검사라 할 수 있다.

CT Scan Mode와 관전압 변경에 따른 소아 두부 영상의 선량 및 영상평가 (Dose and Image Evaluation of Pediatric Head Image according to CT Scan Mode and kVp Changes)

  • 김병제;김동현
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.801-808
    • /
    • 2023
  • 소아 두부 CT 검사 시 방사선 피폭 최소화와 진단적 가치가 높은 영상을 확보하기 위하여 Volume Axial Mode, High Pitch Mode, Helical Mode 간 피폭 선량과 영상의 비교 분석을 통하여 Volume Axial Mode의 유용성을 평가하였다. 1세 미만의 소아 두부 CT Helical Mode, High Pitch Mode, Volume Axial Mode에서 70, 80, 100 kVp의 관전압에 따라 영상평가와 선량평가를 시행하였다. 영상평가는 각 영상에 ROI를 설정해 SNR과 CNR을 산출하여 영상평가를 진행하였으며 일원배치 분산분석(ONE-WAY ANOVA)을 사용하여 통계적 유의성을 평가하였고, 선량평가는 검사 후 장비에서 직접 제공하는 Dose Report에 표시되는 DLP값을 이용하여 비교 분석하였다. Volume Axial Mode를 사용하여 검사하였을 때, DLP 값은 전체적으로 낮게 나왔고, SNR과 CNR은 각각 ROI와 kVp별 차이를 가졌다. Volume Axial Mode가 다른 Scan Mode와 비교하여 영상의 질을 평가하였을 때, 그 차이 값이 균일하지 않아 특정 Mode가 우수하다고 볼 수 없었으나 선량 측면에서는 가장 피폭선량을 줄일 수 있었다. 또한 Volume Axial Mode의 짧은 스캔 시간과 Table의 이동 없이 제자리에서 검사 할 수 있는 점은 방사선 감수성이 높은 1세 미만 소아 CT검사에서 유용하게 적용된다.

저응력하의 철/크롬 올버레이합금의 긁힘마모기구 (Low streee Abrasive Wer mechanism of the Iron/Chromium Hardfacing Alloy)

  • 백응률
    • Journal of Welding and Joining
    • /
    • 제16권2호
    • /
    • pp.73-83
    • /
    • 1998
  • This study investigated the relationships between the microstructure and the wear resistance of hardfaced iron/chromium alloys to examine the low stress abrasive wear mechanism. The effects of volume fraction of reinforcing phases(chromium carbide and eutectic phase) were studied. The alloys were deposited once or twice on a mild steel plate using a self-shielding flux cored arc welding process. The low stress abrasion resistance of he alloys against dry sands was measured by the Dry Sand/Ruber Wheel Abrasion Tester (RWAT). The wear resistance of hypoeutectic alloys, below 0.36 volume fraction of chromium-carbide phase (VFC), behaved as Equal Pressure Mode (EPM) for the inverse rule of mixture whereas the wear resistance of hypereutectic alloys, above 0.36 VFC, represented Equal Wear Mode (EWM) for the linear rule of mixture.

  • PDF

소아안신탕(小兒安神湯)이 STRESS를 유발한 흰쥐의 적출심장(摘出心臟)에 미치는 영향 (Effects of Soaansintang(SOAT) on the hemodynamics and electrocardiogram of isolated rat hearts induced by electrical stimulation)

  • 이승준;이진용;김덕곤
    • 대한한방소아과학회지
    • /
    • 제14권2호
    • /
    • pp.1-32
    • /
    • 2000
  • It has long been known that SOAT is effective for sudden palpitation occurring unexpectedly in Oriental Medicine. However, effect of SOAT on the isolated heart has not been studied yet. The purpose of this study is to investigate the effect of SOAT on hemodynamics and ECG of isolated rat hearts induced by electrical stimulation using Langendorff perfusion apparatus for nonworking heart. SOAT extract was manufactured by water-alcohol precipitated method. Sprague-Dawley rats weighting $120{\sim}150g$ were used for the experiments, Subject animals were divided into four groups, which are consisted of 1) control(Group orally administered by normal saline 1ml for 14days), 2) sample A(Group orally administered by SOAT extract 1ml for 14days), 3) sample C(Group injected by SOAT extract 0.5ml after stimulation, 4) sample C(Group injected by SOAT extract 1ml after stimulation. To evluate the effects of SOAT on hemodynamics and ECG of isolated rat heart induced by stimulation, heart rate, left ventricular pressure, systolic power, diastolic power, coronary artery perfusion volume and ECG were measured using Langendorff apparatus in both stimulation mode(5 volts, 450 beats/min) and arrythmic mode(5 volts, 420 beats/min including 60 beats/min) The results obtained are as follows : 1. After receiving stressful electrical stimuli, isolated heart showed the heart rate, left ventricular pressure, systolic power, diastolic power, coronary artery perfusion volume were all decreased temporarily, but perfusion continued longer recovery to the control state appeared. However, the coronary artery perfusion volume diminished continuously. 2. The heart rates did not change significantly with both stimulation mode and arrhythmic mode, among experimental groups. 3. The left ventricular pressure showed with both stimulation mode and arrhythmic mode, the significant changes(p<0.05) especially in the injection sample group. In case of stimulation mode, low concentration injection group(0.5ml) was more significantly increased rather than high concentration group(1ml) and in case of arrhythmic mode, high density group(1ml) was so increased than the other(0.5ml). 4. For the systolic power and diastolic power, no significant changes were noticed in the stimulation mode, but in the arrhythmic mode of injection sample groups, significant change(p<0.05) was noticed in both systolic power and diastolic power. Specially the high concentration group(1ml) showed more significant increase than the low concentration group. 5. For the coronary artery perfusion volume, no significant change difference among sample groups was observed in both the stimulation mode and the arrhythmic mode. 6. For the ECG recordings, arrhythmia was induced by electrical stimulus of arrythmia mode and after the stimulus was removed, irregular wave appeared temporarily, but as perpusion continued, recovery to the control state was abtained like the stimulation mode. According to the above results, SOAT significantly changed the hemodynamic data from the electrically stressed, isolated hearts of connected Langendorff perfusion apparatus and we propose SOAT has the direct effects on the muscular function of heart.

  • PDF

경량화용 박육부재의 형상비가 압궤특성에 미치는 영향 (Influence of dimensional ratio on collapse characteristics for the thin-walled structures of light weight)

  • 정종안;김정호;양인영
    • 한국안전학회지
    • /
    • 제13권3호
    • /
    • pp.11-23
    • /
    • 1998
  • In this study, collapse test of thin-walled structure is performed under axially quasi-static and impact load in collapse characteristic to develop the optimum structural member for a light-oriented automobile. Furthermore, the energy-absorbing capacity is observed according to the variety of configuration(circular, square), aspect ratio in aluminum specimen to obtain basic data for the improved member of vehicle. In both quasi-static and impact collapse test, Al circular specimens collapse, in general, with axisymmetric mode in case of thin thickness while collapse with non-axisynmetric mode according to the thickness increase. For Al rectangular specimens, they collapse with axisymmetric mode in case of thin thickness, with mixed collapse mode according to the increase of thickness. In terms of initial max. load, Al square specimen turns out the best member among specimens, and then Al square, circular and circular with large scaling ratio, respectively. In case of quasi-static compression test, the absorbed energy per unit volume and mass shows higher in Al circular specimen, and then Al square, circular with large scaling ratio, respectively, according to shape ratio the absorbed energy per unit volume and mass in case of max. impact compression load is higher than that of static load. But the absorbed energy per unit volume and mass shows that Al circular specimen is the best member. Especially, unlike max. compression loan, the absorbed energy per unit volume and mass in impact test turns out the low value.

  • PDF

Cavitation Characteristics of a Pump-turbine Model by CFD Analysis

  • Singh, Patrick Mark;Chen, Chengcheng;Chen, Zhenmu;Choi, Young-Do
    • 한국유체기계학회 논문집
    • /
    • 제18권4호
    • /
    • pp.49-55
    • /
    • 2015
  • The pumped storage plant operates with quick change of the discharge as well as quick changes between pump mode and turbine mode. This study focuses on the cavitation analysis of a pump-turbine model because in turbo-machinery, cavitation can reduce the performance and shorten service life. The pump-turbine model system consists of 7 blades, 20 stay vanes (including tongue) and 20 guide vanes. This study adopts the Rayleigh-Plesset model as a cavitation model, which illustrates cavitation by using the air volume fraction method. The pump mode and turbine mode at the operating condition of partial loading, normal and excessive loading are analyzed to investigate the cavitation performance of the pump-turbine. It was observed that this pump-turbine design showed very good cavitation characteristics with no cavitation bubbles in all operating conditions. Overall value of air volume fraction of both mode at different operating condition are lower than 1, which confirms low possibility of cavitation occurrence at current situation.

ISG 시스템용 고효율 양방향 DC-DC 컨버터의 설계 및 자율적이며 끊김없는 모드전환을 위한 제어전략 (Design and Control Strategy for Autonomous and Seamless Mode Transition of High Efficiency Bidirectional DC-DC Converter for ISG Systems)

  • 박준성;권민호;최세완
    • 전력전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.19-26
    • /
    • 2016
  • In this study, a bidirectional DC-DC converter for idle stop and go (ISG) is developed to reduce fuel consumption. A three-phase non-isolated half-bridge converter is selected through a design method by considering efficiency and volume. According to the state of charge of the batteries at both the low-voltage and high-voltage sides, buck mode, which charges a low-voltage battery from the generated motor energy, and boost mode, which provides power to the motor from the low- and high-voltage battery sides, are required in the ISG system. Hence, an autonomous and seamless bidirectional control method using a variable current limiter is proposed for mode change. A 1.8 kW engineering sample of the proposed converter has been built and tested to verify the validity of the proposed concept. The maximum efficiencies, including gate driver and control circuit losses, are 96.4% in charging mode and 96.1% in discharging mode.

지하철 승강장 형식에 따른 정량적 화재 위험성 평가 (Quantitative Fire Risk Assesment for the Subway Platform Types)

  • 이동호;김하영
    • 한국안전학회지
    • /
    • 제21권6호
    • /
    • pp.1-6
    • /
    • 2006
  • Subway platform is divided into Side-platform type and Center-platform type. In this study does quantitative fire risk assesment of subway platform types in numerical analysis by using CFD model. From the result of this study, 1) All exhaust mode was low-end result it seems most fire risk at Side-platform station. 2) All exhaust mode was low-end result it seems most fire risk at Center-Platform station. 3) When comparing same type exhaust mode of Side-platform and Center-platform that last thing was visible $9.1{\sim}72.34%$ low-end fire risk. Center-platform is more opera-tive than Side-platform that reduce fire risk when that was same dimension and external environment. Designer look upon a fire characteristic of subway platform types when he make smoke control air volume and platform area design.

PM10/2.5/1/0 Trichotomous 도입부 설계 밀 성능평가 (Design and performance of Low-Volume PM10/2.5/1.0 Trichotomous Sampler Inlet)

  • Song Chang-Byeong;Kim Hyeon-Tae;Lee Gyu-Won
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2002년도 추계학술대회 논문집
    • /
    • pp.358-359
    • /
    • 2002
  • Particulate matter smaller than $10{\mu}textrm{m}$ in aerodynamic diameter (PM10) is known as thoracic particles that are capable of reaching the thoracic region of humans. PM10 is further divided into two size ranges, which are fine particles (nuclei mode plus accumulation mode) and coarse particles, based on different sources and chemical composition. Fine particles can penetrate deep into the alveolar region of the human lungs, while coarse particles be deposited in the upper respiratory system. (omitted)

  • PDF