• Title/Summary/Keyword: Luminous environment

Search Result 80, Processing Time 0.029 seconds

Analysis of the Change of Intensity Distribution and Luminous Environment by Reflector Shape in Indirect Reflected LED Luminaires (간접 반사형 LED 조명기구의 반사판 형태에 따른 배광형태 및 조명환경 변화 분석)

  • Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.9-17
    • /
    • 2011
  • Development of high efficiency and eco-friendly LED source has been progressed continuously. Also, by nation's regulations, public institutions have changed existing luminaires to LED luminaires. However, there are several differences between existing luminaires and the intensity distribution of general planar LED luminaires. In case of changing existing luminaires to LED luminaires, by such differences, there are inefficiencies both quality aspect and energy aspect in luminous environment. Therefore, this study aims to conduct a study on the changes of intensity distribution and luminous environment by reflector shapes in indirect reflected LED luminaires with software for optical design of a luminaire (Photopia 2.0) and lighting design of a space (ReluxPro). This study shows the changes of intensity distribution and luminous environment of indirect reflected LED luminaires and indirect fluorescent lamp luminaires by reflector shapes.

Measurement and Analysis of Luminous Environment in Apartments (공동주택의 실내공간별 빛환경 측정 및 조명평면 분석)

  • Lee, Jung-Eun;Choi, An-Seop;Choi, Sung-Youl
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.19-23
    • /
    • 2004
  • Light is an environmental element which is essential for a man to live and do creative activities in residential area. Especially, modern people arc used to live under artificial light interior surroundings for much time. Currently, the average illumination level of the present apartment is improving, but it still does not reach the recommended level because the present apartment's luminous environment is only based on the life behavior which puts its priority to clear vision. Therefore, it is necessary that proper standard illumination must be used for various use and purpose. From this point of view, this paper investigated the essence of light in the residential area and the luminous environment for apartments was measured. This paper finally suggested well-coordinated lighting condition, derived from the measurement and analysis of luminous environment in these cases.

  • PDF

Influence of Luminous Environments on Visual Responses and Fatigue Sensation in Art Galleries (미술관의 조명환경 변화에 따른 시각적 반응 및 피로감각 변화분석)

  • Park, Yoon-Hye;Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.61-72
    • /
    • 2011
  • The influences of luminous environment on visual responses and fatigue sensation in art galleries were examined in this study. Field measurements and survey were performed in three galleries under various illuminance and luminous conditions. Result implies that vertical illuminance on art paintings needed to be somewhere between 200 lx and 300 lx to avoid visual discomfort. The vertical illuminance difference between consecutive paintings should not exceed 100 lx to keep visually comfortable environment. Visual comfort sensations were related to glare, visual stimulus, reflection from paintings, illuminance variation, and the sensation that subjects can clearly see the paintings. The sensation of fatigue was significantly influenced by the changes of luminous element that caused visual stimulus and discomfort. The sensation of eye fatigue among physical fatigue was primarily influenced by the glare, visual stimulus and comfort. The psychological fatigue was also influenced by eye fatigue, visual comfort, brightness and satisfaction with color of light.

A Luminous Environment of Outdoor Spaces in Apartment Complexes (아파트 단지(團地) 외부공간(外部空間)의 빛 환경(環境)에 관(關)한 연구(硏究))

  • Kwon, So-Young;Ha, Mi-Kyoung;Lee, Hyo-Chang
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.237-241
    • /
    • 2006
  • The Qualitative improvements of outdoor spaces are unsatisfactory in comparison with that of indoor environment in existing apartments. Lately construction companies are differentiating the outdoor spaces of apartment complexes to meet needs of residents. However, high-rise buildings inherently have limitations on providing exposure to the outdoor settings and inappropriate lightings could have serious impacts on physical and psychological health of residents. Therefore, the purpose of this study is to provide useful information for the luminous environment of outdoor spaces through the analysis of current apartment complexes' lighting plans. Outdoor space of branded apartment complexes in Seoul, built after the year 2003, were researched. Through site visits, illumination level and lighting plans were investigated classified into entry area, passage area, plaza, rest area, exercise area, and play area. With the result, illumination level of apartment complexes researched was lower than KS illumination standard in all areas and the lighting plans were mostly shown in different condition of first intended lighting plan because of insufficiency of maintenance in lighting system. Therefore, it is need to provide better luminous environment to make outdoor space more lively and energetic at the night time.

  • PDF

A Study of Luminous Environment for Standard Illuminance in Residential Areas (주거공간의 실내공간별 조도기준을 위한 빛환경 연구)

  • Lee, Jung-Eun;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.1-9
    • /
    • 2005
  • Light is an important environmental element for people to live and do creative activities in residential areas. Especially, people are used to live under artificial light in artificial interior surroundings for the most times. Currently, the lighting quality of residential areas has been improved, but it still does not reach to the recommended level because the luminous environment of present residential areas is only based on the life behavior which puts its priority to clear vision. Therefore, it is necessary that proper standard illumination must be used for various uses and purposes. From this point of view, this paper investigated the essence of light in residential areas, and the luminous environment for apartments was measured This paper finally established well-coordinated standard illuminance, derived from the measurement and analysis of luminous environment from these cases.

Evaluating Interior Glare Base on Shading Adjustments (창호의 차양 조절에 따른 실내 글레어 평가)

  • Lim, Sang-Hoon
    • Journal of Korean Living Environment System
    • /
    • v.20 no.2
    • /
    • pp.233-237
    • /
    • 2013
  • Daylighting affects the luminous environment and provides comfortable environment to the occupants. However, excessive daylighting might have negative influences on the visual comfort. Skylight, light intensity and distribution, and insolation could cause glare effects on the occupants. This study analyzed the effect of fenestration on the interior glare effects, and verified luminous environment adjustability through mock up test of conventional fenestration and 'Convergence Window System' by analyzation of luminance, luminance contrast, and glare effect. Consequently, room installed Convergence Window System was improved luminance contrast and PGSV Level.

Measurement of Luminous Environment and Study on Lighting plan for Community Areas (공동주택 커뮤니티 공간의 빛환경 측정 및 조명계획)

  • Lee, Jung-Eun;Choi, An-Seop;Choi, Sung-Youl
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.169-174
    • /
    • 2004
  • As quality of life improves, apartment's residents prefer residing type that have differentiation of resident center. Accordingly, community facilities such as fitness club, swimming pool, and so on are operated in apartment complex. Community areas are important space that can induce inhabitantses' natural meeting and contact, and that can solve social problems which is started each individuals' estrangement in current through community formation between neighborhood. From this point of view, this paper investigated the essence of light and the luminous environment for community areas. This paper finally suggested well-coordinated lighting plan of community areas, derived from the measurement and analysis of luminous environment in these cases.

  • PDF

A Study on Evaluation Structure of luminous Environment in o residential space and office work space (주거.사무공간의 조명환경 평가구조에 관한 연구)

  • 이선영
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.2
    • /
    • pp.1-9
    • /
    • 2003
  • This paper is to find the difference of evaluation structure between a residential space and of ace work space and to examine a relation between mood item and behavior items on evaluation of the luminous environment. First 20 mood items md 15 behavior items were selected for evaluation item on the luminous environment. And then, subjective evaluation was experimented by the semantic differential method. The results are as follows: (1) In respect of evaluation un the mood both luminous environments that have each different character of space at evaluated by the three factors; activity, comfort and quality. (2) In respect of evaluation on the behavior, three factors, work, relaxation and entertainment are selected in the residential space and two factors, work and non-work are selected in the office work space. (3) In the residential space, activity is very important factor that affects on three behaviors, work, relaxation and entertainment. In the office work space, activity affects on work and quality affects on non-work.

The Optical Characteristics of 240 W High Power LED Fish Luring Lamp (240W급 고출력 LED 집어등의 광학적 특성)

  • Bae, Jae-Hyun;An, Heui-Chun;Kim, Sang-Woo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.6
    • /
    • pp.681-687
    • /
    • 2013
  • This study analyzed characteristics of 240 W high power LED lamps by comparing with those of traditional metal halide lamps. In addition, it analyzed the propriety of LED lamps as a source of light, considering seawater transmission characteristics. When Applying white LED package with the color temperature color temperature of 6500K, a 240W-LED fishing lamp has a characteristics of the luminous angle to be expanded to ${\pm}45^{\circ}$, the illumination change was improved to 0.8, as well as the luminance efficiency was improved to 98.8lm/W. As results of comparison between one 1,500W-metal halide lamp and four 240W-LED lamp with considering a seawater transmission and a luminous efficiency of scotopic vision, the radiant flux of two lamps were almost equal level at 50m depth and the luminous flux was 5% higher LED lamp than metal-halide lamp even if only applying the luminous efficiency of scotopic vision. As the luminous flux of LED lmap was 14% higher than that of metal-halide lamp with applying the luminous efficiency of scotopic vision to radiant flux at 50m depth, so LED fishing lamp was verified to alternative possibility of metal-halide lamp.

A STUDY ON THE ILLUMINATION OF DENTAL CLINIC (치과 진료실의 조명에 관한 실태 조사연구)

  • Choi Jong-In;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.