• 제목/요약/키워드: Luminous environment

검색결과 80건 처리시간 0.022초

간접 반사형 LED 조명기구의 반사판 형태에 따른 배광형태 및 조명환경 변화 분석 (Analysis of the Change of Intensity Distribution and Luminous Environment by Reflector Shape in Indirect Reflected LED Luminaires)

  • 김유신;최안섭
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.9-17
    • /
    • 2011
  • Development of high efficiency and eco-friendly LED source has been progressed continuously. Also, by nation's regulations, public institutions have changed existing luminaires to LED luminaires. However, there are several differences between existing luminaires and the intensity distribution of general planar LED luminaires. In case of changing existing luminaires to LED luminaires, by such differences, there are inefficiencies both quality aspect and energy aspect in luminous environment. Therefore, this study aims to conduct a study on the changes of intensity distribution and luminous environment by reflector shapes in indirect reflected LED luminaires with software for optical design of a luminaire (Photopia 2.0) and lighting design of a space (ReluxPro). This study shows the changes of intensity distribution and luminous environment of indirect reflected LED luminaires and indirect fluorescent lamp luminaires by reflector shapes.

공동주택의 실내공간별 빛환경 측정 및 조명평면 분석 (Measurement and Analysis of Luminous Environment in Apartments)

  • 이정은;최안섭;최성열
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.19-23
    • /
    • 2004
  • Light is an environmental element which is essential for a man to live and do creative activities in residential area. Especially, modern people arc used to live under artificial light interior surroundings for much time. Currently, the average illumination level of the present apartment is improving, but it still does not reach the recommended level because the present apartment's luminous environment is only based on the life behavior which puts its priority to clear vision. Therefore, it is necessary that proper standard illumination must be used for various use and purpose. From this point of view, this paper investigated the essence of light in the residential area and the luminous environment for apartments was measured. This paper finally suggested well-coordinated lighting condition, derived from the measurement and analysis of luminous environment in these cases.

  • PDF

미술관의 조명환경 변화에 따른 시각적 반응 및 피로감각 변화분석 (Influence of Luminous Environments on Visual Responses and Fatigue Sensation in Art Galleries)

  • 박윤혜;김수영
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.61-72
    • /
    • 2011
  • The influences of luminous environment on visual responses and fatigue sensation in art galleries were examined in this study. Field measurements and survey were performed in three galleries under various illuminance and luminous conditions. Result implies that vertical illuminance on art paintings needed to be somewhere between 200 lx and 300 lx to avoid visual discomfort. The vertical illuminance difference between consecutive paintings should not exceed 100 lx to keep visually comfortable environment. Visual comfort sensations were related to glare, visual stimulus, reflection from paintings, illuminance variation, and the sensation that subjects can clearly see the paintings. The sensation of fatigue was significantly influenced by the changes of luminous element that caused visual stimulus and discomfort. The sensation of eye fatigue among physical fatigue was primarily influenced by the glare, visual stimulus and comfort. The psychological fatigue was also influenced by eye fatigue, visual comfort, brightness and satisfaction with color of light.

아파트 단지(團地) 외부공간(外部空間)의 빛 환경(環境)에 관(關)한 연구(硏究) (A Luminous Environment of Outdoor Spaces in Apartment Complexes)

  • 권소영;하미경;이효창
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.237-241
    • /
    • 2006
  • The Qualitative improvements of outdoor spaces are unsatisfactory in comparison with that of indoor environment in existing apartments. Lately construction companies are differentiating the outdoor spaces of apartment complexes to meet needs of residents. However, high-rise buildings inherently have limitations on providing exposure to the outdoor settings and inappropriate lightings could have serious impacts on physical and psychological health of residents. Therefore, the purpose of this study is to provide useful information for the luminous environment of outdoor spaces through the analysis of current apartment complexes' lighting plans. Outdoor space of branded apartment complexes in Seoul, built after the year 2003, were researched. Through site visits, illumination level and lighting plans were investigated classified into entry area, passage area, plaza, rest area, exercise area, and play area. With the result, illumination level of apartment complexes researched was lower than KS illumination standard in all areas and the lighting plans were mostly shown in different condition of first intended lighting plan because of insufficiency of maintenance in lighting system. Therefore, it is need to provide better luminous environment to make outdoor space more lively and energetic at the night time.

  • PDF

주거공간의 실내공간별 조도기준을 위한 빛환경 연구 (A Study of Luminous Environment for Standard Illuminance in Residential Areas)

  • 이정은;최안섭
    • 조명전기설비학회논문지
    • /
    • 제19권3호
    • /
    • pp.1-9
    • /
    • 2005
  • 주거공간에서 빛은 인간이 삶을 영위하고 창조활동을 하기 위해서는 꼭 필요한 환경요소이다. 특히 현대인들은 많은 시간을 인공적으로 꾸며진 실내환경 속에서 인공적인 빛을 밝히고 생활하는데 익숙해 있다. 현재 주택에서의 빛환경은 공간마다 명시성 위주의 생활행위에만 기준을 두고 있어 평균조도가 증가되기는 하였다. 그러나 주거공간은 다양한 용도와 목적으로 여러 생활행위가 행해지므로 이것에 대응시킬 수 있는 다양한 조도설정이 필요하다. 본 연구에서는 주거공간에서의 빛의 본질을 파악하고, 공동주택을 대상으로 실내공간별 빛환경을 측정하였다. 이를 통해 공동주택의 조명평면 및 문제점을 분석하여 우리나라 주거조명환경에 적합한 조도기준을 제안하고자 하였다.

창호의 차양 조절에 따른 실내 글레어 평가 (Evaluating Interior Glare Base on Shading Adjustments)

  • 임상훈
    • 한국생활환경학회지
    • /
    • 제20권2호
    • /
    • pp.233-237
    • /
    • 2013
  • Daylighting affects the luminous environment and provides comfortable environment to the occupants. However, excessive daylighting might have negative influences on the visual comfort. Skylight, light intensity and distribution, and insolation could cause glare effects on the occupants. This study analyzed the effect of fenestration on the interior glare effects, and verified luminous environment adjustability through mock up test of conventional fenestration and 'Convergence Window System' by analyzation of luminance, luminance contrast, and glare effect. Consequently, room installed Convergence Window System was improved luminance contrast and PGSV Level.

공동주택 커뮤니티 공간의 빛환경 측정 및 조명계획 (Measurement of Luminous Environment and Study on Lighting plan for Community Areas)

  • 이정은;최안섭;최성열
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.169-174
    • /
    • 2004
  • As quality of life improves, apartment's residents prefer residing type that have differentiation of resident center. Accordingly, community facilities such as fitness club, swimming pool, and so on are operated in apartment complex. Community areas are important space that can induce inhabitantses' natural meeting and contact, and that can solve social problems which is started each individuals' estrangement in current through community formation between neighborhood. From this point of view, this paper investigated the essence of light and the luminous environment for community areas. This paper finally suggested well-coordinated lighting plan of community areas, derived from the measurement and analysis of luminous environment in these cases.

  • PDF

주거.사무공간의 조명환경 평가구조에 관한 연구 (A Study on Evaluation Structure of luminous Environment in o residential space and office work space)

  • 이선영
    • 조명전기설비학회논문지
    • /
    • 제17권2호
    • /
    • pp.1-9
    • /
    • 2003
  • 본 연구는 공간 특성이 서로 다른 주거공간과 사무공간의 조명환경 평가구조에 어떠한 차이가 있는지를 파악하고, 분위기항목과 행위항목과의 관계를 정립하는데 목적을 두고 먼저 조명환경에 대한 평가항목으로써 20개의 분위기항목과 15개의 행위항목을 선정하였다. 그리고 SD법에 의한 주관평가실험을 실시하였다. 그 결과, 공간의 특성이 달라도 조명환경의 분위기평가는 <활동성>, <안정감>, <고급감>의 3인자로 설명이 가능한 것으로 나타났다. 행위 인자에 있어서는 주거공간의 경우 <작업행위>,<휴식행위>,<오락행위>의 3인자가 추출되었고, 사무공간의 경우 <작업행위>, <비작업행위>의 2인자가 추출되었다. 주거공간에서의 3가지 행위인자를 설명하는데 있어서 가장 커다란 영향을 미치는 분위기인자는 <활동성>인자로 나타났으며, 사무공간의 경우, <작업행위>는 <활동성>인자가, <비작업행위>는 <고급감>인자가 가장 큰 영향을 미치고 있는 것으로 나타났다.

240W급 고출력 LED 집어등의 광학적 특성 (The Optical Characteristics of 240 W High Power LED Fish Luring Lamp)

  • 배재현;안희춘;김상우
    • 해양환경안전학회지
    • /
    • 제19권6호
    • /
    • pp.681-687
    • /
    • 2013
  • 본 연구에서는 240 W급 고출력 LED 집어등의 특성을 기존 메탈 집어등과 비교하여 배광 패턴의 특성 및 광효율을 분석하고, 파장 대역의 특성을 해양 투과 특성 및 시감도를 고려하여 집어등 광원으로써 적정성을 분석하였다. 색온도 6500 K, white LED 패키지를 적용한 240 W LED 집어등의 특성을 보면 배광각은 ${\pm}45^{\circ}$, 조도 변화률이 0.8로 개선되었으며, 광효율은 98.8 lm/W로 향상되었다. LED 집어등의 해수의 투과율과 인간의 암순응시 시감도를 1,500 W 메탈등 1개와 4개의 240 W LED 집어등에 적용하여 비교한 결과, 방사출력이 수심 50 m에 이르면 거의 동등하였으며, 암순응시 시감도만을 적용한 경우에도 LED 집어등이 약 5 % 정도 높은 광속을 나타내었으며, 수심 50 m의 방사출력에 암순응시 시감도를 적용한 경우 LED 집어등의 광속이 14 % 높게 나타나 메탈등의 대체 가능성을 확인할 수 있었다.

치과 진료실의 조명에 관한 실태 조사연구 (A STUDY ON THE ILLUMINATION OF DENTAL CLINIC)

  • 최종인;김유리;동진근
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.