• 제목/요약/키워드: M2 Steel

검색결과 1,931건 처리시간 0.029초

Galvanic Corrosion of Zn/Steel Couple in Aqueous MgCl2

  • Tada, E.;Katakami, S.;Nishikata, A.
    • Corrosion Science and Technology
    • /
    • 제16권4호
    • /
    • pp.183-186
    • /
    • 2017
  • Galvanic corrosion tests of Zn/steel couples were conducted in 1 M NaCl and $1M\;MgCl_2$ solutions to investigate the impact of magnesium ion on corrosion behavior of the couples. Two types of Zn/steel couples were used for measurements of open circuit potential (OCP) and galvanic current. From the results of OCP transient of Zn/steel couples, the corrosion potential in $1M\;MgCl_2$ was a more positive value than that in 1 M NaCl during the sacrificial dissolution of Zn. However, earlier increase of OCP of the couples in $1M\;MgCl_2$ solution indicates that the sacrificial dissolution rate of Zn in $1M\;MgCl_2$ was enhanced more than that in 1 M NaCl, agreeing with the results on transients of galvanic current. This result is due to that cathodic reaction on the steel surface of the Zn/steel couple was enhanced in $1M\;MgCl_2$ by the occurrence of hydrogen evolution reaction.

Thiadiazolopyrimidines as Acid Corrosion Inhibitors for Mild Steel

  • Chitra, S.;Parameswari, K.;Vidhya, M.;Kalishwari, M.;Selvaraj, A.
    • Corrosion Science and Technology
    • /
    • 제10권1호
    • /
    • pp.13-23
    • /
    • 2011
  • The inhibitive action of thiadiazolopyrimidines on mild steel in 1 M $H_{2}SO_{4}$ has been studied using weight loss, gasometric studies and electrochemical polarization and AC impedance measurements. The effect of temperature on the corrosion behaviour of mild steel in 1 M $H_{2}SO_{4}$ with optimum concentration of inhibitors was studied in the temperature ranging from 313-333K The adsorption of the inhibitor on the surface of mild steel was found to be exothermic, spontaneous and followed the mechanism of physisorption. The adsorption of these compounds on mild steel surface was found to obey Langmuir adsorption isotherm. The protective film formed on the surface of mild steel by the adsorption of inhibitor in 1 M $H_{2}SO_{4}$ solution was confirmed by optical microscopic technique. Synergistic effect of halide ions on mild steel in 1 M $H_{2}SO_{4}$ was studied by weight loss technique.

철근의 적정량 산출에 관한 연구 (A Study on Evaluation of Frost Damage of High-Flowing Concrete using Blast-Furnace Slag)

  • 임칠순;이규철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2001년도 학술논문발표회
    • /
    • pp.148-156
    • /
    • 2001
  • The korean Standard of the length of steel bar is 6m and 8m for building structures. This paper is to investigate the length of steel bar to reduce the loss of steel bar comparing with the steel length(6m, 8m) using today. This research shows that using of the others length of steel bar(7m, 9m) is able to reduce the loss up to 2.27%.

  • PDF

Behaviour of soil-steel composite bridge with various cover depths under seismic excitation

  • Maleska, Tomasz;Beben, Damian
    • Steel and Composite Structures
    • /
    • 제42권6호
    • /
    • pp.747-764
    • /
    • 2022
  • The design codes and calculation methods related to soil-steel composite bridges and culverts only specify the minimum soil cover depth. This value is connected with the bridge span and shell height. In the case of static and dynamic loads (like passing vehicles), such approach seems to be quite reasonable. However, it is important to know how the soil cover depth affects the behaviour of soil-steel composite bridges under seismic excitation. This paper presents the results of a numerical study of soil-steel bridges with different soil cover depths (1.00, 2.00, 2.40, 3.00, 4.00, 5.00, 6.00 and 7.00 m) under seismic excitation. In addition, the same soil cover depths with different boundary conditions of the soil-steel bridge were analysed. The analysed bridge has two closed pipe-arches in its cross section. The load-carrying structure was constructed as two shells assembled from corrugated steel plate sheets, designed with a depth of 0.05 m, pitch of 0.15 m, and plate thickness of 0.003 m. The shell span is 4.40 m, and the shell height is 2.80 m. Numerical analysis was conducted using the DIANA programme based on the finite element method. A nonlinear model with El Centro records and the time history method was used to analyse the problem.

가스압 함침 공정으로 제조된 TiB2-steel 금속복합재료의 미세조직 및 기계적 물성에 관한 연구 (A Study on Microstructure and Mechanical Properties of TiB2-steel Composite Fabricated by Gas Pressure Infiltration Process)

  • 이지혜;이동현;조승찬;권한상;이상관;이상복;김정환
    • Composites Research
    • /
    • 제35권4호
    • /
    • pp.248-254
    • /
    • 2022
  • 본 연구에서는 가스압 함침공정을 이용하여 고체적률 TiB2-steel 복합재료를 제조하였으며, 미세조직 분석과 압축강도 및 경도를 측정하였다. 복합재료의 미세조직과 기계적 물성과의 연관성을 고찰하고자, 압축시험 후 시편의 파면을 분석하고 압축시험 중 시편의 파괴 거동을 예측하였다. 파면 분석 결과, 기지금속과 강화상 입자간의 계면파괴 흔적이 관찰되었으며, 이에 기지금속과 강화상의 계면을 TEM을 사용하여 분석하였다. 제조된 복합재료의 미세조직 분석 결과, TiB2 강화상 및 steel 기지상 이외에 TiC 상과 조대한 (Fe,M)2B (M=Cr,Mn)상이 생성된 것을 확인할 수 있었으며, 열역학 계산을 통하여 공정조건에서 TiC와 (Fe,M)2B가 안정상으로 생성될 수 있음을 확인하였다. 제조된 TiB2-steel 복합재료는 기지 금속 대비 경도가 크게 상승하였으며, 상온 압축강도 및 탄성계수는 각각 3.07배, 1.95배 향상되었다. 복합재료 내부 전반에 생성된 조대한 (Fe,M)2B (M=Cr,Mn)상이 기계적 물성 저하를 일으키는 것으로 보이며, (Fe,M)2B (M=Cr,Mn)상의 생성을 제어함으로써 TiB2-steel 복합재료의 기계적 물성을 추가적으로 향상시킬 수 있을 것이라 생각한다.

Effect of hysteretic constitutive models on elasto-plastic seismic performance evaluation of steel arch bridges

  • Wang, Tong;Xie, Xu;Shen, Chi;Tang, Zhanzhan
    • Earthquakes and Structures
    • /
    • 제10권5호
    • /
    • pp.1089-1109
    • /
    • 2016
  • Modified two-surface model (M2SM) is one of the steel elasto-plastic hysteretic constitutive models that consider both analysis accuracy and efficiency. However, when M2SM is used for complex strain history, sometimes the results are irrational due to the limitation of stress-strain path judgment. In this paper, the defect of M2SM was re-modified by improving the judgment of stress-strain paths. The accuracy and applicability of the improved method were verified on both material and structural level. Based on this improvement, the nonlinear time-history analysis was carried out for a deck-through steel arch bridge with a 200 m-long span under the ground motions of Chi-Chi earthquake and Niigata earthquake. In the analysis, we compared the results obtained by hysteretic constitutive models of improved two-surface model (I2SM) presented in this paper, M2SM and the bilinear kinematic hardening model (BKHM). Results show that, although the analysis precision of displacement response of different steel hysteretic models differs little from each other, the stress-strain responses of the structure are affected by steel hysteretic models apparently. The difference between the stress-strain responses obtained by I2SM and M2SM cannot be neglected. In significantly damaged areas, BKHM gives smaller stress result and obviously different strain response compared with I2SM and M2SM, and tends to overestimate the effect of hysteretic energy dissipation. Moreover, at some position with severe damage, BKHM may underestimate the size of seismic damaged areas. Different steel hysteretic models also have influences on structural damage evaluation results based on deformation behavior and low cycle fatigue, and may lead to completely different judgment of failure, especially in severely damaged areas.

신형상 냉간성형 단면의 구조적 거동(II) - 휨거동 (Structural Behavior of Newly Developed Cold-Formed Steel Sections(II) - Flexural Behavior)

  • 송인섭;김갑득;권영봉
    • 한국강구조학회 논문집
    • /
    • 제14권2호
    • /
    • pp.357-364
    • /
    • 2002
  • 스터드, 조이스트 및 지붕 트러스에 적용하기 위한 폐단면 냉간성형부재의 휨실험을 수행하고 해석치와 비교하여 보았다. 길이 2.4m, 폭 0.9m의 휨 시편은 46cm 간격의 두 개의 강재보의 한면에 석고보드와 합판을 부착한 시편과 부착하지 않은 시편으로 구성되었고, 각 시편에 대한 정, 부모멘트실험을 수행하여, 강재보에 부착된 합판 및 석고보드가 강재의 좌굴거동에 미치는 영향을 포함한 합성거동을 파악하였다. 또한 합판이 부착된 실물 트러스 실험을 통하여 트러스 부재의 좌굴거동 및 파괴양상에 대하여 연구하였다.

The study on the influence of surface cleanness and water soluble salt on corrosion protection of epoxy resin coated carbon steel

  • Shon, MinYoung
    • Corrosion Science and Technology
    • /
    • 제13권5호
    • /
    • pp.163-169
    • /
    • 2014
  • The corrosion resistance of epoxy-coated carbon steel was evaluated. The carbon steel surface was subjected to different treatment methods such as steel grit blasting and power tool treatment as well as contamination of water soluble salt. To study the effect of the surface treatments and contamination, the topology of the treated surface was observed by confocal microscopy and a pull-off adhesion test was conducted. The corrosion resistance of the epoxy-coated carbon steel was further examined by electrochemical impedance spectroscopy (EIS) combined with immersion test of 3.5 wt% of NaCl solution. Consequently, the surface contamination by sodium chloride with $16mg/m^2$, $48mg/m^2$ and $96mg/m^2$ didn't affect the adhesion strength for current epoxy coated carbon steel and blister and rust were not observed on the surface of epoxy coating contaminated by various concentration of sodium chloride after 20 weeks of immersion in 3.5 wt% NaCl aqueous solutions. In addition, the results of EIS test showed that the epoxy-coated carbon steel treated with steel grit blasting and power tool showed similar corrosion protection performance and surface cleanness such as Sa 3 and Sa 2.5 didn't affect the corrosion protectiveness of epoxy coated carbon steel.

Al과 스텐레스강의 주조접합을 위한 STS430(Fe-17wt.%Cr)강의 표면처리 특성연구 (A Study on the Surface Characterization of Fe-17wt.%Cr Steel for Cast-bonding of Al and Stainless Steel)

  • 김억수
    • 한국주조공학회지
    • /
    • 제25권3호
    • /
    • pp.134-141
    • /
    • 2005
  • To overcome the undesirable deformation, peeling off and geometrical restrictions which were mainly caused by differences in thermal expansion coefficients during the cladding of aluminum strip and stainless strip, new processing method based on vacuum die casting is designed and implemented in fabricating Al/Fe-17wt%Cr steel(stainless steel). To increase cast-bonding ability, the surface of Fe-17wt%Cr steel is electrochemically etched to have optimum pit size and density. The optimum conditions to generate best pit are as follows: Solution: 1 M $Fecl_{3}$+1 M Nacl, Addition: $CuCl_{2}+HCl$, Current density: 80 $mA/cm^{2}$, Total current: 400 $coulomb/cm^{2}$, AC frequency :60 Hz.