• Title/Summary/Keyword: MIMIC

Search Result 821, Processing Time 0.033 seconds

The Study on Differences of Performance by Mimic Investment Pattern of IT Project (IT 프로젝트 모방 투자 유형에 따른 성과 차이 연구)

  • Jung, Byungho;Kim, Byungcho
    • Journal of Information Technology Services
    • /
    • v.11 no.3
    • /
    • pp.205-225
    • /
    • 2012
  • The purpose of this study is to examine negative IT performances produced by irrational fashion-mimic IT investments in firms. Since most studies have been carried out on the assumption of rational investment decisions, many of them have revealed positive investment process and performances in firms. However, fashion-mimic investments to follow the paths of market leaders rather than rational investment decisions have been of frequent occurrence in many firms. This study divided types of mimic investments into subgroups where one subgroup has fashion-mimic properties and the other subgroup retains rational-mimic properties. We compared differences in performance of these subgroups to investigate effects of irrational investments in IT projects. The results indicated that there are differences in performance between fashion-mimic and rational-mimic investments. Additional analysis also revealed differences in performance at the presence of CEO control in the case of fashion-mimic investment subgroup.

Study on the tree-mimic array of solar cell modules (수목형상에 따른 태양전지 모듈의 배열 연구)

  • Kim, Ki-Hyun;Yun, Rin
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.32-39
    • /
    • 2011
  • This study is about the installation of the solar cell modules. The solar cell modules are built by the tree-mimic structure, and the performance is compared with that of the flat-plate type solar cell module installation. The mathematical tree model, which was suggested by Fisher and Honda, is utilized to determine the location of the solar cell modules for the tree-mimic type. The experiment shows that the generated electric power of the flat-plate type is higher than that of the tree-mimic type by 30% for one month of July. This lower performance for the tree-mimic type comes from the shading effects among the solar cell modules. The theoretical calculation for the absorbed solar radiation on the two types of solar cell installation shows that the tree-mimic type is higher than the flat-plate type by 8.5%. The shading area for the tree-mimic model is calculated with time by using the 3D-CAD, which will be utilized for the optimization of the tree-mimic model in the future.

Design and Fabrication of 100 GHz MIMIC Amplifier Using Metamorphic HEMT (Metamorphic HEMT를 이용한 100GHz MIMIC 증폭기의 설계 및 제작)

  • 안단;이복형;임병옥;이문교;백용현;채연식;박형무;이진구
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.9
    • /
    • pp.25-30
    • /
    • 2004
  • In this Paper, the 0.1 w InGaAs/InAlAs/GaAs Metamorphic HEMT, which is applicable to MIMIC, and a 100 GHz MIMIC amplifier were designed and fabricated. The DC characteristics of MHEMT are 640 mA/mm of drain current density, 653 mS/mm of maximum transconductance. The current gain cut-off frequency(fT) is 173 GHz and the maximum oscillation frequency(fmax) is 271 GHz. A 100 GHz amplifier was designed using 0.1${\mu}{\textrm}{m}$ MHEMT and CPW technology. The measured results from the 100 GHz MIMIC amplifiers show good S21 gain of 10.1 dB and 12.74 dB at 100 GHz and 97.8 GHz, respectively.

Design and Development of MIMIC regarding Telemetry in LEO Satellites (저궤도 관측위성에서의 원격 측정 데이터 관련 MIMIC 설계 및 구현)

  • Huh, Yun-Goo;Kim, Young-Yun;Cho, Seung-Won;Choi, Jong-Yeoun
    • Aerospace Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.42-48
    • /
    • 2012
  • The telemetry data received from satellite in real-time are used to monitor LEO satellite during the AIT (Assembly, Integration & Test) phase and the mission operation phase after launch. However, it is impossible to check all the incoming telemetry data from satellite in real time in order to detect abnormality of satellite quickly. Especially, the contact time of LEO satellite is limited because of its orbital characteristics. So the anomaly state of the LEO satellite should be detected and resolved during the contact time. Therefore, all incoming spacecraft telemetry data must be selected and manipulated in MIMIC. It is used in order to display summarized information about spacecraft in a visualized way that is quickly and easily understood. That is, it provides essential function to monitor a satellite both in orbit and during testing. In this paper, the design and development of MIMIC currently used in KOMPSAT, a LEO Earth observation satellite is described in detail. In future work, we plan to enhance MIMIC in order to improve user-friendliness and efficiency.

Low Conversion Loss 94 GHz MHEMT MIMIC Resistive Mixer (낮은 변환손실 특성의 94 GHz MHEMT MIMIC Resistive 믹서)

  • An Dan;Lee Bok-Hyung;Lim Byeong-Ok;Lee Mun-Kyo;Oh Jung-Hun;Baek Yong-Hyun;Kim Sung-Chan;Park Jung-Dong;Shin Dong-Hoon;Park Hyung-Moo;Park Hyun-Chang;Kim Sam-Dong;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.5 s.335
    • /
    • pp.61-68
    • /
    • 2005
  • In this paper, low conversion loss 94 GHz MIMIC resistive mixer was designed and fabricated. The $0.1{\mu}m$ InGaAs/InAlAs/GaAs Metamorphic HEMT, which is applicable to MIMIC's, was fabricated. The DC characteristics of MHEMT are 665 mA/mm of drain current density, 691 mS/mm of maximum transconductance. The current gain cut-off frequency(fT) is 189 GHz and the maximum oscillation frequency(fmax) is 334 GHz. A 94 GHz resistive mixer was fabricated using $0.1{\mu}m$ MHEMT MIMIC process. From the measurement, the conversion loss of the 94 GHz resistive mixer was 8.2 dB at an LO power of 10 dBm. P1 dB(1 dB compression point) of input and output were 9 dBm and 0 dBm, respectively. LO-RF isolations of resistive mixer was obtained 15.6 dB at 94.03 GHz. We obtained in this study a lower conversion loss compared to some other resistive mixers in W-band frequencies.

Studies on the High-gain Low Noise Amplifier for 60 GHz Wireless Local Area Network (60 GHz 무선 LAN의 응용을 위한 고이득 저잡음 증폭기에 관한 연구)

  • 조창식;안단;이성대;백태종;진진만;최석규;김삼동;이진구
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.11
    • /
    • pp.21-27
    • /
    • 2004
  • In this paper, millimeter-wave monolithic integrated circuit(MIMIC) low noise amplifier(LNA) for V-band, which is applicable to 60 GHz wireless local area network(WLAN), was fabricated using the high performance 0.1 ${\mu}{\textrm}{m}$ $\Gamma$-gate pseudomorphic high electron mobility transistor(PHEMT). The DC characteristics of PHEMT are drain saturation current density(Idss) of 450 mA/mm and maximum transconductance(gm, max) of 363.6 mS/mm. The RF characteristics were obtained the current gain cut-off frequency(fT) of 113 GHz and the maximum oscillation frequency(fmax) of 180 GHz. V-band MIMIC LNA was designed using active and passive device library, which is composed of 0.1 ${\mu}{\textrm}{m}$ $\Gamma$-gate PHEMT and coplanar waveguide(CPW) technology. The designed V-band MIMIC LNA was fabricated using integrated unit processes of active and passive device. The measured results of V-band MIMIC LNA are shown S21 gain of 21.3 dB, S11 of -10.6 dB at 60 GHz and S22 of -29.7 dB at 62.5 GHz. The measured result of V-band MIMIC LNA was shown noise figure (NF) of 4.23 dB at 60 GHz.

A motion capture and mimic system (운동포착 및 재현 시스템)

  • 윤중선;최원수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1344-1347
    • /
    • 1996
  • A general procedure for motion capture and mimic system has been delineated. Utilizing sensors operated in the magnetic fields, complex and optimized movements are easily digitized to analyze and follow. Design concepts of the system are modular, open, and user friendly to ensure the overall system performance. The system consists of motion capture, visualization, plan, mimic and GUI modules. This procedure is currently being implemented on a virtual cyber cube.

  • PDF

Reduction of Mimic Sound in Outside Mirrors Using Jury Test (청음 평가를 이용한 자동차 OUTSIDE MIRROR 의 MIMIC 소음 개선)

  • Lee Jeonghan;Ih Kangduck;Jeong Seung Gyun
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.393-396
    • /
    • 2001
  • 차량 주행시 발생되는 소위 mimic 소음은 접이식 outside mirror의 접합부에서 발생하는 이음(異音)으로서 예민한 승객에게 지적된다. Mimic 소음은 2kHz이 상의 고주파 영역에서 특정 대역에 간헐적으로 발생하는 소음이며, 시간에 대해 앙상블 에버리지를 하는 일반적인 분석 방법으로는 나타나지 않는다. 그러나 주의 깊은 청취에 의해 그 존재를 분명히 느낄 수 있으므로 다꾸찌 시험 계획법에 의거 실험 샘플을 제작하여 녹음한 뒤, 청음 평가를 통하여 개선하는 과정을 거쳤다. 분석 결과 mimic 소음은 folding gap의 폭보다는 균일도를 유지하는 것이 중요하며, gap내의 공동(공동, cavity)을 메워 주는 것이 효과적이라는 결론을 얻었다.

  • PDF

miR-126 Suppresses the Proliferation of Cervical Cancer Cells and Alters Cell Sensitivity to the Chemotherapeutic Drug Bleomycin

  • Yu, Qing;Liu, Shan-Ling;Wang, He;Shi, Gang;Yang, Pei;Chen, Xin-Lian
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6569-6572
    • /
    • 2013
  • In cervical cancer, one of the most common malignant tumors in women worldwide, miR-126 has been reported to exhibit decreased expression. However, its role in cervical cancer cell proliferation and drug sensitivity has remained relatively unexplored. Here, we compared the expression of miR-126 in cervical cancer tissues (n = 20) with that in normal cervical tissue (n = 20) using quantitative RT-PCR. The viability of Siha cervical cancer cells was further measured by MTT assay after transfection with miR-126 mimic (Siha-miR-126 mimic) or microRNA mimic negative control (Siha-miR mimic NC) and after treatment with various concentrations of bleomycin (BLM). IC50s were calculated, and the survival rates (SRs) of Siha cells were calculated. miR-126 expression in cervical cancer tissue was significantly decreased compared with that in normal cervical tissue (P < 0.01). The relative SRs of Siha-miR-126 mimic cells were also significantly decreased compared with those of Siha-miR mimic NC cells at 24-96 h after transfection. The IC50 of BLM in Siha-miR-126 mimic cells ($50.3{\pm}2.02{\mu}g/mL$) was decreased compared with that in Siha-miR mimic NC cells ($70.5{\pm}4.33{\mu}g/mL$) at 48 h after transfection (P < 0.05). Finally, the SRs of Siha-miR-126 mimic cells were significantly lower than those of SihamiR mimic NC cells after cultured in medium containing 40 ${\mu}g/mL$ BLM for 24-96 h (P < 0.05). These results suggest that miR-126 is expressed at low levels in cervical cancer. Upregulation of miR-126 inhibited cervical cancer cell proliferation and enhanced the sensitivity to BLM. Thus, miR-126 may represent a novel approach to cervical cancer treatment.

A Study on Design and Fabrication of High Isolation W-band MIMIC Single-balanced Mixer (높은 격리도 특성의 W-밴드용 MIMIC 단일 평형 주파수 혼합기의 설계 및 제작 연구)

  • Yi, Sang-Yong;Lee, Mun-Kyo;An, Dan;Lee, Bok-Hyung;Lim, Byeong-Ok;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.11
    • /
    • pp.48-53
    • /
    • 2007
  • In this paper, a high LO-RF isolation W-band MIMIC single-balanced mixer was designed and fabricated using a branch line coupler and a ${\lambda}/4$ transmission line. The W-band MIMIC single-balanced mixer was designed using the $0.1\;{\mu}m$ InGaAs/InAlAs/GaAs Metamorphic HEMT diode. The fabricated MHEMT was obtained the cut-off frequency($f_T$) of 154 GHz and the maximum oscillation frequency($f_{max}$) of 454 GHz. The designed MIMIC single-balanced mixer was fabricated using $0.1\;{\mu}m$ MHEMT MIMIC process. From the measurement, the conversion loss of the single-balanced mixer was 12.8 dB at an LO power of 8.6 dBm. P1 dB(1 dB compression point) of input and output were 5 dBm and -8.9 dBm, respectively. The LO-RF isolations of single-balanced mixer was obtained 37.2 dB at 94 GHz. We obtained in this study a higher LO-RF isolation compared to some other balanced mixers in millimeter-wave frequencies.