• Title/Summary/Keyword: MMI

Search Result 252, Processing Time 0.038 seconds

Development of MMI System for Smart Temperature controller with Android Platform (안드로이드 플랫폼을 탑재한 스마트 온도제어기의 MMI 시스템 개발)

  • Lee, Kap Rai
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.4
    • /
    • pp.457-465
    • /
    • 2019
  • This paper present developing methods of man-machine interface(MMI) system for smart temperature controller with android platform. This MMI system could communicate with mobile machine. Firstly we present electrical hardware design method of MMI system of smart temperature controller. Smart temperature controller is composed of dual processors. Secondly we develop operating software of MMI system using android development environment. And finally we present verification of MMI systems of smart temperature controller with android platform through field experiment. This MMI system with android platform has rapid development speed due to performance of android platform.

The development of the MMI system for automating steel-making process (제철 공정 자동화를 위한 MMI 시스템 개발)

  • Lee, Dae-Sung;Kim, Yoon-Ha;Joo, Moon-Jab
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2469-2471
    • /
    • 2002
  • MMI 시스템은 제철 공정에서 발생되는 다양한 데이터를 조업자에게 쉽고 빠르게 전달하기 위해, real time operating system에서 동작하는 제철공정의 주된 제어 프로세스와 인터페이스 한다. 따라서 MMI 시스템은 제철 공정의 주된 제어 프로세스와 ethernet network을 통해 공유 데이터들을 통신하도록 개발되고, MMI 시스템은 M/S window operating system과 DDE(Dynamic Data Exchange) 라이브러리 환경을 기반으로 개발된다. 수 개의 MMI client PC와 1 개의 MMI server로 구성되는 MMI 시스템은 MMI client들 사이의 공유 데이터가 동기화될 수 있도록 최적 packet 양을 도출하고, 신뢰성 높은 데이터 전송을 위한 특별한 데이터 핸들링 방법을 사용한다. MMI 시스템은 GUI(Graphic User Interface)를 사용하여 조업자에게 친숙한 window 화면을 제공하므로, MMI 시스템의 화면 수정, 첨가 및 삭제가 비용 부담없이 용이하게 진행되므로, 기존 제철 공정에서 사용하던 OCP(Operating Control Panel)들이 MMI 시스템으로 대체되고 있다.

  • PDF

Characteristics of $1{\times}N$ MMI Optical Power Splitters Fabricated by $Ag^+-Na^+$ Ion-exchange ($Ag^+-Na^+$ 이온교환법으로 제작된 $1{\times}N$ MMI 광파워 분리기의 특성)

  • Jeon, Keum-Soo;Jang, Myung-Ho;Kang, Dong-Sung;Kim, Hee-Ju;Pan, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.8
    • /
    • pp.34-42
    • /
    • 2001
  • The 1${\times}$2, 1${\times}$4 and 1${\times}$8 multimode interference(MMI) optical power splitters are fabricated by using $Ag^+-Na^+$ ion exchange on BK7 glass. Before fabricating the MMI optical power splitters, we find the refractive index of the channel waveguide and calculate the multimode section length and width. The multimode section lengths and widths are 887${\mu}m$, 1666${\mu}m$ and 1834${\mu}m$ and 40${\mu}m$, 80${\mu}m$ and 120${\mu}m$ for 1${\times}$2, 1${\times}$4 and 1${\times}$8 MMI optical power splitters respectively. The measured properties of the fabricated MMI optical power splitters show that the unbalance ratios of the 1${\times}$2, 1${\times}$4 and 1${\times}$8 MMI optical power splitters are 1.4[dB], 1.7[dB] and 2.0[dB] and the excess losses of those sre 0.96[dB], 2.26[dB] and 1.67[dB]. respectively.

  • PDF

An introduction to the MMI system of strip casting Process (박판주조공정의 MMI 시스템 소개)

  • Joo, Moon-G.;Lee, D.S.;Kim, Y.H.;Kang, T.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2778-2780
    • /
    • 2000
  • MMI system for strip caster 2 is described. It has been developed as a PC-based MMI system whose data is collected from the VME-based control system by ETHERNET. MMI elements that mimic the caster and its utilities are designed by using commercial program. In order to implement the UDP/IP communication in MMI, UDP/IP manager program with DDE that is a intercommunication protocol in MS-window is developed and connected with MMI mimics. Operator commands in MMI system are carried out immediately in VME system and the responses are displayed on MMI system. The developed MMI system has been proven to be convenient and stable through the operation of the past 5 years.

  • PDF

Device Miniaturization using Butterfly Grating-Assisted MMI Couplers (나비형 격자구조 다중모드 간섭 결합기를 사용한 소자의 소형화)

  • Ho, Kwang-Chun
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.25-30
    • /
    • 2008
  • In this paper, a novel architecture for device miniaturization of multimode interference-based (MMI) couplers is proposed. The coupling length of $N{\times}N$ MMI couplers scales as the square of the MMI region width so that the use of these structures with large-N ports can require large chip size. To solve the design problem, the butterfly grating-assisted MMI couplers, that have smaller device dimensions than conventional MMI couplers, are discussed and evaluated. Numerical simulations and novel design rules for such structures derived through theoretical analysis are presented.

Study on the Relations to Estimate Instrumental Seismic Intensities for the Moderate Earthquakes in South Korea (국내 중규모 지진에 대한 계측진도 추정식 연구)

  • Yun, Kwan-Hee;Lee, Kang-Ryel
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.6
    • /
    • pp.323-332
    • /
    • 2018
  • Recent two moderate earthquakes (2016 $M_w=5.4$ Gyeongju and 2017 $M_w=5.5$ Pohang) in Korea provided the unique chance of developing a set of relations to estimate instrumental seismic intensity in Korea by augmenting the time-history data from MMI seismic intensity regions above V to the insufficient data previously accumulated from the MMI regions limited up to IV. The MMI intensity regions of V and VI was identified by delineating the epicentral distance from the reference intensity statistics in distance derived by using the integrated MMI data obtained by combining the intensity survey results of KMA (Korea Meteorological Administration) and 'DYFI (Did You Feel It)' MMIs of USGS. The time-histories of the seismic stations from the MMI intensity regions above V were then preprocessed by applying the previously developed site-correction filters to be converted to a site-equivalent condition in a manner consistent with the previous study. The average values of the ground-motion parameters for the three ground motion parameters of PGA, PGV and BSPGA (Bracketed Summation of PGA per second for 30 seconds) were calculated for the MMI=V and VI and used to generate the dataset of the average values of the ground-motion parameters for the individual MMIs from I to VI. Based on this dataset, the linear regression analysis resulted in the following relations with proposed valid ranges of MMI. $MMI=2.36{\times}log_{10}(PGA(gal))+1.44$ ($I{\leq}MMI$$MMI=2.44{\times}log_{10}(PGV(kine))+4.86$ ($I{\leq}MMI$$MMI=2.59{\times}log_{10}(BSPGA(gal{\cdot}sec))-1.02$ ($I{\leq}MMI$

Design of Polarization-Insensitive Directional Couplers and Multimode Interference Couplers Integrated with Bragg Grating Waveguide (Bragg 격자구조가 집적된 편광 무의존성 방향성 결합기와 다중모드 간섭 결합기의 설계)

  • Ho, Kwang-Chun
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.295-302
    • /
    • 2007
  • This paper presents a rigorous comparison of the design characteristics of polarization-insensitive directional coupler (DC) and multimode interference (MMI) coupler based on rib type waveguides, by using longitudinal modal transmission-line theory (L-MTLT). It shows that the multimode mixing and interference property of MMI can be structurally designed through the continuous evolution of the two-mode coupling property of DC. It also compares and analyzes the coupling efficiency along with the coupling length and the wavelength between polarization-insensitive DC and MMI. From the design properties obtained, it demonstrates for the first time the integration of polarization-insensitive DC or MMI with a Bragg grating and evaluates precisely the filtering characteristics. The numerical results reveal that the DC, as long as it is designed to have the same coupling length for TE and TM modes, has better performance than the MMI in polarization-insensitive filtering behaviour. However, it shows that the MMI with much less coupling length than DC is preferred in the miniaturization of integrated devices.

Instrumental Seismic Intensity based on Fourier Acceleration Spectra of the earthquake ground-motion (지진파의 가속도 푸리에스펙트럼 크기를 이용한 계측진도 평가)

  • Yun, Kwan-Hee;Park, Dong-Hee;Park, Se-Moon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.6
    • /
    • pp.27-37
    • /
    • 2009
  • A method of instrumentally estimating seismic intensity (MMI) based on the Fourier Acceleration Spectrum of earthquake ground-motion, the so-called 'FAS MMI method' of Sokolov and Wald (2002), was evaluated for its applicability to Korea based on the empirical models of mean (m) and standard deviation (${\sigma}$) for Korea according to individual seismic intensity for MMI ${\leq}$ IV (Yun et al., 2009). This evaluation showed that the error in estimating the seismic intensity using the FAS MMI method is ${\sigma}$ = 0.74 MMI, and was further reduced to ${\sigma}$ = 0.61 MMI if the dependency of the error on earthquake magnitude and distance is additionally corrected. It is also shown that FAS MMI based on the FAS semi-empirically evaluated from small earthquakes for damaging earthquakes in Korea with maximum MMI ${\geq}$ VI could predict the observed MMI with the maximum error of 0.63 by using the combined FAS m-${\sigma}$ models of Korea for MMI ${\leq}$ IV and global region for MMI ${\geq}$ V.

Novel Design in 1x2-MMI using Low-Loss Mode Adapter (저손실 광모드 변환기를 장착한 1x2-MMI 최적 설계법)

  • 송준호;홍정무;박순룡;이승걸;박세근;이일항;오범환
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.162-163
    • /
    • 2003
  • 광 집적회로를 설계하는데 있어서 Y-형 분배기는 광에너지를 분배 혹은 결합시키는 중요한 역할을 한다. 그러나 이 소자는 분기 부분에서의 큰 손실과 공정상에서의 두 분기사이를 식각하는 것은 쉽지 않다는 단점을 갖고 있다. Y-형 분배기와 더불어 광신호의 분리와 결합에 있어서 널리 사용되는 MMI 분배기 소자는효율적인 분배 기능을 유도하기 위해서 MMI 내에 모드수가 많아져야 하는데, 이런 방식의 모드 수의 증가를 유도하기에는 MMI-길이와 폭에 제한을 받게 된다. (중략)

  • PDF

The development of VR Simulator MMI for Kori #1 NPP (고리원자력 1호기 운전용 가상 시뮬레이터 MMI 개발)

  • 김은정;서인용;이용관
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2003.11a
    • /
    • pp.165-171
    • /
    • 2003
  • We have developed Virtual Reality Simulator MMI for operator training. MMI communicates with server model and client PC through OPCServer. We used Dataplant for Soft Panel and Simdiagram which shows more sophisticated and reality colors. We used vector method for MCR images instead of conventional bit-map method to protect images during zoom in and zoom out. VBScript and Components were used for real movements and images of instruments. VRMCR panel is consisted of 12 groups and designed to accommodate user's convenience.

  • PDF