• 제목/요약/키워드: MRI

검색결과 4,143건 처리시간 0.037초

Leak Sign on Dynamic-Susceptibility-Contrast Magnetic Resonance Imaging in Acute Intracerebral Hemorrhage

  • Park, Ji Kang;Hong, Dae Young;Jin, Sun Tak;Lee, Dong-Woo;Pyun, Hae Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권3호
    • /
    • pp.154-161
    • /
    • 2020
  • Purpose: A CT angiography spot sign (CTA-spot) is a significant predictor of the early expansion of an intracerebral hemorrhage (ICH-Ex). Dynamic-susceptibility-contrast magnetic resonance imaging (DSC-MRI) can track the real-time leaking of contrast agents. It may be able to indicate active bleeding, like a CTA-spot. Materials and Methods: From September 2014 to February 2017, we did non-contrast CT, CTA, and DSC-MRI examinations of seven patients with acute ICH. We investigated the time from symptom onset to the first contrast-enhanced imaging. We evaluated the time course of the contrast leak within the ICH at the source image of the DSC-MRI and the volume change of ICH between non-contrast CT and DSC-MRI. We compared the number of slices showing CTA-spots and DSC-MRI leaks. Results: The CTA-spot and DSC-MRI leak-sign were present in four patients, and two patients among those showed ICH-Ex. The time from the symptom onset to CTA or DSC-MRI was shorter for those with a DSC-MRI leak or CTA-spot than for three patients without either (70-130 minutes vs. 135-270 minutes). The leak-sign began earlier, lasted longer, and spread to more slices in the patients with ICH-Ex than in those without ICH-Ex. The number of slices of the DSC-MRI leak and the number of the CTA-spot were well correlated. Conclusion: DSC-MRI can demonstrate the leakage of GBCA within hyperacute ICH, showing the good contrast between hematoma and contrast. The DSC-MRI leakage sign could be related to the hematoma expansion in patients with ICH.

지방 종괴의 진단에 대한 MRI의 판별 능력 (Results of MRI Evaluation for the Fatty Masses)

  • 서재성;안종철;김정래;최준혁;조길호;신덕섭
    • 대한골관절종양학회지
    • /
    • 제11권1호
    • /
    • pp.25-31
    • /
    • 2005
  • 목적: MRI가 지방종과 고분화 지방 육종을 구분할 수 있는가를 알아보고, 지방종과 고분화 지방 육종이 생기는 위치, 깊이, 크기, 환자의 성별 및 연령 등과 상관관계가 있는지를 알아보고자 하였다. 대상 및 방법: 본원에서 수술한 107명의 지방 종괴 환자 중, MRI를 재검토 할 수 있었던 47명의 환자를 대상으로 하였다. MRI의 판독 결과와 수술 후 병리학적 소견을 비교하여, MRI의 감수성, 특이성, 진단율, 양성 예상치 및 음성 예상치를 계산하였으며, 종양의 위치, 깊이, 크기, 조영 증강의 유무, 환자의 나이 및 성별 등과 종양의 악성 혹은 양성 여부와의 상관관계를 비교 분석 하였다. 결과: MRI 판독 결과 28례에서 지방종으로 진단되었고, 19례에서 고분화 지방 육종의 진단 기준에 합당하거나 가능성이 있는 소견을 나타내었다. MRI에서 지방종으로 판단한 28례 중 병리 조직 판독 소견과 비교하여, 실제 지방종은 26례였으며 나머지 2례는 지방종 변종인 혈관지방종이었다. 고분화 지방 육종으로 판단한 19례 중 실제 고분화 지방 육종은 6례였으며, 나머지 13례는 지방종 변종 10례와 지방종 3례로 나타났다. 지방종 변종의 종류로는 섬유 지방종, 혈관지방종, 방추상세포 지방종, 지방아세포종과 혈관근지방종 등이 있었다. MRI 의 고분화 지방 육종에 대한 감수성은 100%, 특이성은 68%, 진단율은 72%, 양성 예상치는 31%, 음성 예상치는 100%였으며, 지방종은 각각 90%, 89%, 89%, 93%, 84%였다. 양성지방 종양 군과 고등급 지방 육종 군을 구별 할 수 있는 변수들의 상관관계 분석에서, 조영 증강 유무 와 종양의 크기가 통계적으로 유의하였다(p<0.05). 결론: MRI는 고분화 지방육종의 진단에 감수성이 강하고, 지방종의 진단에 특이성이 강한 것으로 나타났으며, 비특이적 소견을 보일 때는 지방종 변종을 염두에 두어야 할 것으로 사료된다. 지방 종괴의 크기가 10 cm 가 넘고, MRI에서 조영증강이 되는 부분이 있으면 고분화 지방 육종을 의심하여야 하고, MRI 소견이 비 특이적일 때는 지방종 변종을 생각하여야한다.

  • PDF

MRI 영상의 PSNR 평가 (PSNR Appraisal of MRI Image)

  • 강광수;이준행
    • 한국방사선학회논문지
    • /
    • 제3권4호
    • /
    • pp.13-21
    • /
    • 2009
  • MRI System은 각종 여러 가지 Parameter들로 구성되어 있다. 그중 MRI 영상의 화질을 빼놓고 MRI를 논한다는 것은 어려운 일이다. 각종 Parameter들이 개발되고 발전되어오면서 MRI영상에서도 예전 System에서 보여지는 영상과는 비교 할 수 없을 정도의 고화질을 출력하고 있다. 그리고 방사선 영상 System이 고식적인 Film방식에서 digital방식으로 전환되어가고 있고 그에 따른 병원의 모든 시스템이 전산화가 되어가고 있다. 방사선 영상의 관리에 있어서 저장 이라는 부분이 아주 중요한 ��을 차지하고 있다. 그 방대한 자료를 Server에 저장하는 방법으로는 압축을 이용 하여 저장하는 방법을 사용하게 된다. 이 때 발생한 문제점은 원본 영상에 비해 압축시 영상의 화질 저하가 발생한다는 것이다. 의료 영상에서는 조그마한 화질저하도 오진의 우려가 있으므로 각별히 주의해야할 사항이다. 본 논문에서는 병원에서 진료중인 영상을 대상으로 각각의 파일 변환과 원본과의 비교, 원본 영상과 진료에 사용되어지는 모니터에서의 MRI 영상의 화질을 PSNR을 이용한 평가와 영상 평가방법에 의한 평가를 하였다. 실험결과 원본과 각종 영상 압축방법을 이용하여 압축한 영상을 비교 분석 하였는데 화질저하가 거의 나타나지 않았다. 하지만 원본영상을 display하는 모니터의 화질 에서 상당한 문제점이 드러났다. 판독용 모니터 와 의료용 모니터에서는 손색없는 고해상도의 영상을 출력해 냈는가 반면 일반 CRT, LCD 모니터에서는 각종 노이즈, 영상왜곡등 많은 문제점들이 나타났다.

  • PDF

Factors Influencing the Background Parenchymal Enhancement in Follow-Up Breast MRI after Adjuvant Endocrine Therapy

  • Youk, Ji Hyun;Son, Eun Ju;Kim, Jeong-Ah
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권2호
    • /
    • pp.99-106
    • /
    • 2015
  • Purpose: To investigate factors influencing the evaluation of background parenchymal enhancement (BPE) at follow-up breast magnetic resonance imaging (MRI) after adjuvant endocrine therapy. Materials and Methods: One hundred twelve women with breast cancer and MRI of the contralateral unaffected breast before and after endocrine therapy were identified. Two readers in consensus performed blinded side-by-side comparison of BPE (minimal, mild, moderate, and marked) before and after therapy with categorical scales. Age, body mass index, menopausal status, treatment regimen (selective estrogen receptor modulator or aromatase inhibitor), chemotherapy, follow-up duration, BPE at baseline MRI, MRI field strength before and after therapy, and recurrence were analyzed for their influences on decreased BPE. Results: Younger age, premenopausal status, treatment with selective estrogen receptor modulator, MRI field strength, and moderate or marked baseline BPE were significantly associated with decreased BPE. In multivariate analysis, MRI field strength and baseline BPE showed a significant association. Conclusion: MRI field strength and baseline BPE before and after therapy .were associated with decreased BPE at post-therapy, follow-up MRI.

Compressed Sensing 기법을 이용한 Dynamic MR Imaging (Compressed Sensing Based Dynamic MR Imaging: A Short Survey)

  • 정홍;예종철
    • 대한전자공학회논문지SP
    • /
    • 제46권5호
    • /
    • pp.25-31
    • /
    • 2009
  • Compressed sensing은 기존의 Nyquist sampling 이론에 기반을 두었던 dynamic MRI에서의 시 공간 해상도의 제한을 획기적으로 향상시킴으로써, 최근 몇 년 사이, MR reconstruction 분야에서 가장 큰 이슈가 되고 있는 연구주제이다. Dynamic MRI 는 대부분 시간방향의 redundancy 가 매우 크므로, 쉽게 sparse 변환이 가능하다. 따라서 sparsity를 기본 조건으로 하는 compressed sensing은 거의 모든 dynamic MRI 에 대해 효과적으로 적용될 수 있다. 본 review 페이퍼에서는 최근 compressed sensing 에 기반을 두거나 영상의 sparsity를 이용하여 개발된 dynamic MR imaging algorithm 들을 간략히 소개하고, 비교 분석함으로써, compressed sensing과 같은 새로운 접근 방식의 dynamic MRI가 실제 임상에서 가져다 줄 발전 가능성을 제시한다.

MRI 소음의 특성을 이용한 공동 내부 목표점의 능동소음 제어 (Active Noise Control for Target Point Inside Bore Using Property of MRI Noise)

  • 이록행;박영진;박윤식
    • 한국소음진동공학회논문집
    • /
    • 제24권1호
    • /
    • pp.62-68
    • /
    • 2014
  • Recently, MRI(magnetic resonance imager) scanner is continually used for medical diagnosis and many biomedical researches. When it operates, however, intense noise is generated. The SPL(sound pressure level) of the noise approaches 130 dB especially in 3 T(Tesla) MRI. Meanwhile, more than 3 T MRI scanners have been developed to get higher-resolution images, so louder noise is expected in the future. The intense noise makes patients feel nervous and uncomfortable. Moreover, it could possibly cause hearing loss to patient in extreme cases. For this reason, some active noise control systems have been researched. One of them used feedback Filtered-X LMS(FXLMS) algorithm which is able to control only narrowband noises and possible to diverge in severe case. In this paper, we determine the property of MRI noise. Using the property, we applied a method of open-loop and adaptive control for reducing MRI noise at target point inside bore. We verified performance of the method with computer simulation and preliminary experiment. The results demonstrate that the method can effectively reduce MRI noise at target point.

Electromagnetic design study of a 7 T 320 mm high-temperature superconducting MRI magnet with multi-width technique incorporated

  • Jang, Won Seok;Kim, Geonyoung;Choi, Kibum;Park, Jeonghwan;Bang, Jeseok;Hahn, Seungyong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.30-34
    • /
    • 2021
  • Superconducting magnets have paved the way for opening new horizons in designing an electromagnet of a high field magnetic resonance imaging (MRI) device. In the first phase of the superconducting MRI magnet era, low-temperature superconductor (LTS) has played a key role in constructing the main magnet of an MRI device. The highest magnetic resonance (MR) field of 11.7 T was indeed reached using LTS, which is generated by the well-known Iseult project. However, as the limit of current carrying capacity and mechanical robustness under a high field environment is revealed, it is widely believed that commercial LTS wires would be challenging to manufacture a high field (>10 T) MRI magnet. As a result, high-temperature superconductor together with the conducting cooling approach has been spotlighted as a promising alternative to the conventional LTS. In 2020, the Korean government launched a national project to develop an HTS magnet for a high field MRI magnet as an extent of this interest. We have performed a design study of a 7 T 320 mm winding bore HTS MRI magnet, which may be the ultimate goal of this project. Thus, in this paper, design study results are provided. Electromagnetic design and analysis were performed considering the requirements of central magnetic field and spatial field uniformity.

Fast Real-Time Cardiac MRI: a Review of Current Techniques and Future Directions

  • Wang, Xiaoqing;Uecker, Martin;Feng, Li
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권4호
    • /
    • pp.252-265
    • /
    • 2021
  • Cardiac magnetic resonance imaging (MRI) serves as a clinical gold-standard non-invasive imaging technique for the assessment of global and regional cardiac function. Conventional cardiac MRI is limited by the long acquisition time, the need for ECG gating and/or long breathhold, and insufficient spatiotemporal resolution. Real-time cardiac cine MRI refers to high spatiotemporal cardiac imaging using data acquired continuously without synchronization or binning, and therefore of potential interest in overcoming the limitations of conventional cardiac MRI. Novel acquisition and reconstruction techniques must be employed to facilitate real-time cardiac MRI. The goal of this study is to discuss methods that have been developed for real-time cardiac MRI. In particular, we classified existing techniques into two categories based on the use of non-iterative and iterative reconstruction. In addition, we present several research trends in this direction, including deep learning-based image reconstruction and other advanced real-time cardiac MRI strategies that reconstruct images acquired from real-time free-breathing techniques.

치료계획시스템에서 전산화단층촬영과 자기공명영상의 영상융합 재현성 및 선량평가 (CT and MRI image fusion reproducibility and dose assessment on Treatment planning system)

  • 안병혁;최재혁;황재웅;박지연;이두현
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.33-41
    • /
    • 2017
  • 목 적: 종양에는 최대한의 선량을 부여하고 주변의 정상조직에는 최소한의 선량이 조사되도록 부작용을 줄이는 목적으로 방사선 치료기술이 발전함에 따라 다양한 치료계획 및 치료 방법이 개발되고 있다. 방사선 치료 시 CT(Computed tomography)와 MRI(Magnetic resonance imaging)영상의 융합은 종양에 선량을 전달하는데 커다란 역할을 한다. 본 연구의 목적은 치료계획 시 자체 제작한 팬톰을 이용하여 CT와 MRI영상들의 융합을 통해 영상의 재현성 및 유용성을 평가하고 획득한 영상에서 타겟 선량을 비교, 분석해보고자 한다. 대상 및 방법: 자체 제작한 팬톰을 이용하여 CT 촬영을 하고, 자장의 세기가 다른 1.5T 와 3.0T의 MRI 촬영을 하여 영상을 획득한다. CT 촬영을 한 팬톰의 영상과 각기 다른 자장의 세기로 촬영한 팬톰의 MRI영상에서 팬톰 내에 존재하는 작은 홀의 크기 및 용적의 재현성을 비교하고, 임의의 타겟에서 선량 변화를 비교, 분석한다. 결 과: 13개의 작은 홀 직경은 CT 촬영에서 최대 31 mm, 최소 27.54 mm를 나타냈으며, 실제 제작한 것과 비교하여 평균 29.28 mm 1 % 이내로 측정되었다. 1.5T MRI 퓨전 영상에서는 최대 31.65 mm, 최소 24.3 mm를 나타냈으며, 평균 28.8 mm 1 % 이내로 측정되었다. 3.0T MRI 퓨전 영상에서는 최대 30.2 mm, 최소 27.92 mm를 나타냈으며, 평균 29.41 mm 1.3 % 이내로 측정되었다. 타겟의 조사된 선량변화는 CT에서 95.9-102.1 %, CT-1.5T MRI 퓨전영상에서 93.1-101.4 %, CT-3.0T MRI 퓨전영상에서는 96-102 %의 선량변화를 보였다. 결 론: CT 및 MRI는 영상획득 시 다른 알고리즘이 적용된다. 또한 인체의 장기는 각기 다른 밀도를 가지고 있으므로 영상 획득 시 이미지 왜곡이 발생할 수 있다. 이러한 부정확한 영상의 묘사는 타겟의 용적범위 및 선량에 영향을 주기 때문에 정확한 타겟의 용적과 위치는 불필요한 선량이 조사되는 것을 방지하며, 치료계획 시 오차를 방지할 수 있다. 즉 CT와 MRI 영상이 가지고 있는 영상 표출 알고리즘의 장점을 이용하여 치료계획에 적용해야 할 것이다.

  • PDF

F-18 FDG PET/MRI와 PET/CT 전신 영상에서 VOI를 이용한 정상부위의 $SUV_{LBM}$-최대치에 의한 영상평가 (Image Evaluation Via $SUV_{LBM}$ for Normal Regions of VOI by Using Whole Body Images Obtained from PET/MRI and PET/CT)

  • 박정규;김성규;조인호;공은정;박명환
    • 한국의학물리학회지:의학물리
    • /
    • 제24권1호
    • /
    • pp.68-75
    • /
    • 2013
  • 본 연구의 목적은 26명의 건강한 검진자들을 대상으로 PET/CT와 PET/MRI의 전신 영상에서 조기 정밀/ 진단 수준을 향상하고자 관심부피를 이용하여 정상부위의 $SUV_{LBM}$-최대치를 이용하여 PET/CT와 PET/MRI를 조영제 사용 유무와 관계없이 동시 평가할 수 있는 데이터를 구축하고자 하였다. 전신 F-18 FDG PET/CT와 전신 F-18 FDG PET/MRI의 정상부위의 VOI를 이용한 $SUV_{LBM}$-최대치평가는 PET/CT를 기준으로 PET/MRI의 영상은 매우 유의한 차이를 보였다(p<0.0001). 그러나 통계학적으로 높은 상관관계를 가진다(R>0.8). PET/MRI의 $SUV_{LBM}$ 평가 시 26.3% 감소하여 판단할 것과 조영제를 사용할 경우는 29.3% 감소하여 판단할 것으로 생각한다. PET/CT와 PET/MRI의 모든 영상의 판독에서는 $SUV_{LBM}$-최대치를 사용하는 것이 편리성과 효율성을 고려하여 임상의나 연구자들에게 많은 도움이 되리라 판단된다.