• Title/Summary/Keyword: Magnetic Field Reduction

Search Result 185, Processing Time 0.037 seconds

Power Frequency Magnetic Field Reduction Method for Residents in the Vicinity of Overhead Transmission Lines Using Passive Loop

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Cho, Yeun-Gyu;Lee, Dong-Il;Lim, Yun-Seog;Lee, Sang-Yun
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.829-835
    • /
    • 2011
  • A power frequency magnetic field reduction method using passive loop is presented. This method can be used to reduce magnetic fields generated within the restricted area near transmission lines by alternating current overhead transmission lines. A reduction algorithm is described and related equations for magnetic field reduction are explained. The proposed power frequency magnetic field reduction method is applied to a scaled-down transmission line model. The lateral distribution of reduction ratio between magnetic fields before and after passive loop installation is calculated to evaluate magnetic field reduction effects. Calculated results show that the passive loop can be used to cost-effectively reduce power frequency magnetic fields in the vicinity of transmission lines generated by overhead transmission lines, compared with other reduction methods, such as active loop, increase in transmission line height, and power transmission using underground cables.

Analysis of ELF Magnetic Field Reduction Factor of Electric Power Transmission Line (송전 선로 극저주파 자기장 저감지수(FRF) 특성 해석)

  • Myung, Sung-Ho;Cho, Yeon-Gyu;Lee, Dong-Il;Lim, Yun-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.11 s.114
    • /
    • pp.1132-1142
    • /
    • 2006
  • This paper examined electric power transmission line models of reducing ELF(Extremely Low Frequency) magnetic field and analyzed the effects about models. In this research, FRF(Field Reduction Factor) of various models reducing magnetic field were analyzed compared to the horizontal 154 kV transmission line. As a result, the reduction ratio of magnetic field was almost proportioned to the compaction of phase-to-phase distance, and in case of diamond model and transposed model, magnetic field was able to be reduced nearly 50 %. It was analyzed that the magnetic field reduction ratio of triangle model was about 33 % and the magnetic field reduction ratio of split model was able to be reduced to 50 %. Especially, the magnetic field reduction ratio of multi split model could be reduced to 80 %.

Analysis of ELF Magnetic Field Reduction Ratio on Passive Loop Using Scale Down Model of Transmission Line (축소 모델을 이용한 수동 루프 송전선 자기장 저감율 분석)

  • Cho, Yeun-Gyu;Myung, Sung-Ho;Lee, Jae-Bok;Chang, Sug-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1231-1239
    • /
    • 2006
  • In this research magnetic field reduction effect of each passive loop was analyzed by using the scale down models of transmission lines. This paper examined magnetic field reduction effect of the passive loop that will be applied to actual facility through the experiment, which is about double vertical transmission line and horizontal transmission line. Consequently, by confirming the fact that magnetic field reduction effect can be obtained to 50 % by passive loop without reactive compensation, we insured technology about application of passive loop. And the case of 3 turns of loop showed two times reduction effect than that of 1 turns of loop in reducing magnetic field. Vertical passive loop is more efficient than horizontal passive loop in the aspect of reducing magnetic field on double vertical transmission lines. What is more, vertical passive loop showed good effect of reducing magnetic field in a far distance as well as in a short distance.

Analysis of Magnetic Arc Reduction of Relay Contacts (릴레이 접점의 자기적 아크 저감 분석)

  • Choi, Sun-Ho;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.3
    • /
    • pp.234-240
    • /
    • 2019
  • In this work, the magnetic arc reduction phenomena encountered in AC relay contacts were analyzed. To this end, arc duration, instantaneous voltage, and current changes due to changes in the magnetic field were observed. The arc generated at the contact point was affected by the magnitude of the applied magnetic field; the voltage and current waveforms rapidly intersected, resulting in a decrease in arc duration and arc energy. Furthermore, the orientation of the N pole of the magnetic field was found to play a role in the effectiveness of potential arc prevention.

Feasibility of normal tissue dose reduction in radiotherapy using low strength magnetic field

  • Jung, Nuri Hyun;Shin, Youngseob;Jung, In-Hye;Kwak, Jungwon
    • Radiation Oncology Journal
    • /
    • v.33 no.3
    • /
    • pp.226-232
    • /
    • 2015
  • Purpose: Toxicity of mucosa is one of the major concerns of radiotherapy (RT), when a target tumor is located near a mucosal lined organ. Energy of photon RT is transferred primarily by secondary electrons. If these secondary electrons could be removed in an internal cavity of mucosal lined organ, the mucosa will be spared without compromising the target tumor dose. The purpose of this study was to present a RT dose reduction in near target inner-surface (NTIS) of internal cavity, using Lorentz force of magnetic field. Materials and Methods: Tissue equivalent phantoms, composed with a cylinder shaped internal cavity, and adjacent a target tumor part, were developed. The phantoms were irradiated using 6 MV photon beam, with or without 0.3 T of perpendicular magnetic field. Two experimental models were developed: single beam model (SBM) to analyze central axis dose distributions and multiple beam model (MBM) to simulate a clinical case of prostate cancer with rectum. RT dose of NTIS of internal cavity and target tumor area (TTA) were measured. Results: With magnetic field applied, bending effect of dose distribution was visualized. The depth dose distribution of SBM showed 28.1% dose reduction of NTIS and little difference in dose of TTA with magnetic field. In MBM, cross-sectional dose of NTIS was reduced by 33.1% with magnetic field, while TTA dose were the same, irrespective of magnetic field. Conclusion: RT dose of mucosal lined organ, located near treatment target, could be modulated by perpendicular magnetic field.

Flow Control and Drag Reduction of a Circular Cylinder by an External Magnetic Field (자기장을 사용한 원형주상체 주위의 유동 제어 및 저항감소)

  • 윤현식;전호환
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.41 no.2
    • /
    • pp.70-78
    • /
    • 2004
  • The present study numerically investigates two-dimensional laminar flow past a circular cylinder in an aligned magnetic field using the spectral method. Numerical simulations are performed for flow fields with Re=100 and 200 in the range of 0$\leq$N$\leq$10, where Ν is the Stuart number that is the ratio of electromagnetic force to inertial force. The present study reports the detailed information of flow quantities on the cylinder surface at different Stuart numbers. It is shown that the vortex shedding can be controlled by the magnetic force representing the Stuart number. As Ν increases, the vortex shedding becomes weaker, resulting in drag reduction whose magnitude is the largest at a critical value. In addition, as the magnetic force increases, the lift amplitude decreases, reaching zero at the critical number.

Investigation of Shielding Effects of High Conductivity of High Permeability Materials on 60Hz ELF Magnetic Fields (60Hz ELF 자계에 대한 고 도전율 및 고 투자율 재료의 차폐효과 분석)

  • Song Ki-Hyun;Myung Sung-Ho;Min Suk-Won
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.4
    • /
    • pp.166-171
    • /
    • 2005
  • Shielding methods on ELF(Extremely Low Frequency) magnetic fields may include the use of induced currents, modification of magnetic field flux patterns using high permeability and/or high conductivity materials, and others. The magnetic shielding properties of enclosures can be utilized to reduce the magnetic field of current carrying conductors. In this paper, to get a more practical understanding of shielding phenomena, we have investigated the magnetic field reduction by means of 3 dimensional numerical analysis and experiments. We found copper could reduce flux density more then permalloy in both cases of box shield and cylindrical shield. Iron under l0$\mu$T of 1 phase could reduce flux density about $20\%$ more than silicon steel, but both of them under 50$\mu$T has a similar reduction rate of $10\%$. The 3 phase horizontal model gave the highest reduction rate and the 1mm thickness iron under 10$\mu$T of 3 phase lines did lowest.

Improvement of Electromagnetic Shielding Structure for Reduction of the Leakage Magnetic Field in WPT System (WPT 시스템의 누설자계 감소를 위한 전자파 차폐구조 개선)

  • Kim, Jongchan;Lee, Seungwoo;Kang, Byeong-Nam;Hong, Ic-Pyo;Cho, In-Kui;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.1
    • /
    • pp.61-68
    • /
    • 2017
  • In this paper, we propose an improved magnetic field shielding structure to reducing the magnetic field generated in the wireless power transfer system operating at a low frequency band. The proposed structure consists of the magnetic material and the conductive material, magnetic field cancelling effect for power transfer is minimized while improving the leakage magnetic field cancelling effect by optimizing the various design parameters in the proposed structure. We analyzed and verified the efficiency of the wireless power transfer system and the reduction effect of the leakage magnetic field through computer simulation and measurement. Analysis results show that power transfer efficiency of the wireless power transfer system utilizing the proposed structure is 77 %, which is maintained at the conventional power transfer efficiency. In addition, compared with the structure maintaining high power transfer efficiency, leakage magnetic field strength is reduced to 29~37 % at the nearest point.

A Study on Magnetic Field Reduction Design Technique around 345 kV Transmission Line with 2-wire Set Passive Loop (2선식 수동루프를 이용한 345[kV] 송전선 주변의 자계저감 설계기법 연구)

  • Kim, Eung Sik
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.5
    • /
    • pp.10-17
    • /
    • 2021
  • The controversy over the risk of the human body being affected by electromagnetic fields emitted from 60 Hz power lines continues without end. There are currently no new studies or research progress being made in this direction that is notable, and the number of civil complaints is gradually increasing. The problem is that each study produces different results, among which the effect of exposure to magnetic fields on childhood leukemia is a major one. In Korea, an electrician who was maintaining a 22.9 kV power line died of leukemia, which has recently been recognized as an occupational disease. Methods to reduce magnetic fields from power lines include shielding with wire loops, incorporating split phases and compaction techniques, installing underground power lines, converting to high-voltage direct current (HVDC), and increasing the ground clearance of transmission towers. Depending on whether a separate power supply is needed or not, there are two types of wire loops: passive loop and active loop. Magnetic field reduction is currently done through underground power lines; however, the disadvantage of this process is high construction costs. Installing passive loops, with relatively low construction costs, leads to lower magnetic field reduction rates than installing underground cables and a weakness to not solving the landscape problem. This methodological study aims at designing methods and reducing the effects of 2-wire set loops-the simplest and most practical. Since the method proposed in this study has been designed after analyzing the distribution of complex electromagnetic fields near the expected loop installation location, a practical design can be implemented without the need for any difficult optimization programming.

NOx Removal Using DC Corona Discharge Under Magetic Field (자계하의 DC 코로나 방전에 의한 NOx 제거)

  • Kim, G.H.;Kim, Jong-Dal;Lee, D.C.;Koh, H.S.;Park, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.462-464
    • /
    • 1995
  • In this paper, experiments were carried out to study the decrease of NOx in simulated flue gases (initial concentration of NO 1000, 750, 400 ppm, : $N_2$ balance gas). Characteristics of NOx reduction are measured and analysed in corona discharge of multi needles to plane electrode structure and magnetic field. The best characteristics of NO reduction is measured when electric and magnetic field were supplied to reactor, at same time. Consumption power applied electric and magnetic field were higher than that of discharge applied only electric field.

  • PDF