• Title/Summary/Keyword: Matrix material

Search Result 1,832, Processing Time 0.034 seconds

IN VITRO STUDY OF TOOTH TEMPERATURE CHANGE DURING POLYMERIZATION REACT10N OF THE COLD-CURED RESINS USED IN PROVISIONAL CROWN AND FIXED PARTIAL DENTURES (자가 중합 임시수복용 레진의 경화 시 외부환경 변화에 따른 치아의 온도변화)

  • Oh, Wu-Sik;Baik, Jin;Kim, Hyung-Seob;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.503-513
    • /
    • 2006
  • Statement of the problem: The cold-cured resins used in fabrication of the provisional crown and fixed partial dentures could cause pulpal damage by heat generated during exothermic polymerization reactions. Purpose: In this in vitro study investigates the how external conditions such as material of the matrix, thickness of the matrix and thickness of dentin affect the temperature of the tooth during polymerization reaction of the cold-cured resins. Material and methods : To measure the temperature of the resin, metal die was maintained to the temperature of $37^{\circ}C$ with water bath to simulate the temperature of thetooth and thermocouple was placed in the center of the metal die. Acrylic pipe was cut in height of 1, 2, 3, 6, 10 mm and placed on the metal die and mixed resin was pored in the acrylic pipe As the resin polymerized temperature was recorded with the thermometer. Temperature of the resin using matrix was recorded by using the individual tray relieved in different thickness 2, 5, 7, 10 mm. The material of the matrix was irreversible hydrocolloid impression material, vinyl polysilloxane impression material and vacuum-formed template Temperature rise of the resin using different thickness of tooth section was record ed by placing tooth section on the metal die and placing resin over the tooth section. Results : Conclusion : 1. Temperature rise increased as the thickness of the resin increased but there was no significant differences over 3 mm thickness of the resin. 2. The lowest temperature rise was showed in irreversible hydrocolloid impression material and vinyl polysilloxane impression material vacuum-formed template as in orders. 3, Temperature rise of the resin decreased regardless of the thickness of the matrix when vinyl polysilloxane impression material was used as the matrix. 4 When irreversible hydrocolloid impression material was used as matrix, the temperature rise of the resin decreased as the thickness of the matrix increased and there was no temperature rise when thickness of the matrix reached 10 mm, 5. The temperature rise of the resin did not decreased when Polypropylene vacuum-formed template was used as the matrix. 6, The temperature of the resin increased as the thickness of the dentin decreased.

Study on Material Properties of Composite Materials using Finite Element Method (유한요소법을 이용한 복합재의 물성치 도출에 대한 연구)

  • Jung, Chul-Gyun;Kim, Sung-Uk
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.61-65
    • /
    • 2016
  • Composites are materials that are widely used in industries such as automobile and aircraft. The composite material is required as a material for using in a high temperature environment as well as acting as a high pressure environment like the nozzle part of the ship. It is important to know the properties of composites. Result values obtained substituting the properties of matrix and fiber numerically have an large error compared with experimental value. In this study we utilize CASADsolver EDISON program for using Finite Element Method. Properties by substituting the fiber and Matrix properties of the composite material properties were compared with those measured in the experiment and calculated by the empirical properties.

Numerical modelling of nonlinear behaviour of prestressed concrete continuous beams

  • Lou, Tiejiong;Lopes, Sergio M.R.;Lopes, Adelino V.
    • Computers and Concrete
    • /
    • v.15 no.3
    • /
    • pp.373-389
    • /
    • 2015
  • The development of a finite element model for the geometric and material nonlinear analysis of bonded prestressed concrete continuous beams is presented. The nonlinear geometric effect is introduced by the coupling of axial and flexural fields. A layered approach is applied so as to consider different material properties across the depth of a cross section. The proposed method of analysis is formulated based on the Euler-Bernoulli beam theory. According to the total Lagrangian description, the constructed stiffness matrix consists of three components, namely, the material stiffness matrix reflecting the nonlinear material effect, the geometric stiffness matrix reflecting the nonlinear geometric effect and the large displacement stiffness matrix reflecting the large displacement effect. The analysis is capable of predicting the nonlinear behaviour of bonded prestressed concrete continuous beams over the entire loading stage up to failure. Some numerical examples are presented to demonstrate the validity and applicability of the proposed model.

Study of bone healing pattern in extraction socket after application of demineralized dentin matrix material (자가치아 뼈 이식재의 발치와내 이식 후 골 치유 양상에 관한 연구)

  • Chung, Jae-Ho;Lee, Jae-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.5
    • /
    • pp.365-374
    • /
    • 2011
  • Introduction: Research on dental bone graft material has been actively conducted. Recently, demineralized dentin matrix material has been developed and introduced. This study examined the effect of demineralized dentin matrix material on bone healing. Subjects and Methods: The patients who received no treatment after extraction were used as the control group and patients who underwent demineralized dentin matrix material application in the extraction socket after extraction were used as the experimental group. Panorama radiography was performed at the baseline and at 3.5 months after graft material placement and CT was taken at 3.5 months after graft material placement for a radiologic evaluation. Bony tissue specimens were collected from the alveolar crest in the middle of the extraction socket using a 2 mm trephine bur after 3.5 months for the histology and hostomorphometric study. Results: 1. On the panoramic view, a higher bone density was observed in the subject group. 2. On the panoramic view, the bone density increased significantly in the extraction socket, from the baseline to 3.5 months: a 7 and 10 gray-level scale was observed in the control and experimental group, respectively (P<0.05). 3. The CT view evaluation at 3.5 months revealed significantly higher bone density in the subject group than the control group (P<0.05). 4. The histological findings showed more active new bone and lamellar bone formation in the subject group. Dentin with osteoinduction ability and enamel with osteoconduction ability appeared. 5. On histomorphometric analysis, the subject group showed significantly more new bone, lamellar bone area and lower soft tissue area (P<0.05). The difference between the groups was significant (P<0.05). Conclusion: Bone healing was improved after the application of demineralized dentin matrix material and there was active new bone and lamellar bone formation.

The Strength Properties of Metal Matrix Composites by Binder Additives (금속기복합재료의 바인더 첨가제에 따른 강도 특성)

  • Park, Won-Jo;Huh, Sun-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.7
    • /
    • pp.1051-1057
    • /
    • 2003
  • This study is about controlled impurities, which make metal alloys, especially AC4CH alloy that is made by restraining 0.2% Fe and Aluminum to make a matrix material. A metal matrix composite is produced using the squeeze casting method. The first step in the squeeze casting method is to add some organic binder including aluminum borate whisker into the matrix. After the fabrication of a metal matrix composite, each is individually appended to an inanimate binder such as SiO$_2$, Al$_2$O$_3$, and TiO$_2$. Through experiments the mechanical property changes were investigated between the metal matrix composite and AC4CH alloy. This study proves the superiority of the mechanical property of a metal matrix composites over AC4CH according to the previous tests and results that were mentioned above. One excellent property of matrix material composites is the infiltrated TiO$_2$ reinforcement. This material is a good substitute for the existing materials that are used in the development of industries today.

The Strength Properties of Metal Matrix Composites by Binder Additives (금속기복합재료의 바인더 첨가제에 따른 강도 특성)

  • Park, Won-Jo;Lee, Kwang-Young;Huh, Sun-Chul;Choi, Yong-Bum
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.198-203
    • /
    • 2001
  • This study is about controlled impurities, which make metal alloys, especially AC4CH alloy that is made by restraining 0.2% Fe and Aluminum to make a matrix material. A metal matrix composite is produced using the squeeze casting method. The first step in the squeeze casting method is to add some organic binder including aluminum borate whisker into the matrix. After the fabrication of a metal matrix composite, each is individually appended to an inanimate binder such as $SiO_2,\;Al_2O_3$, and $TiO_2$. Through experiments the mechanical property changes were investigated between the metal matrix composite and AC4CH alloy. This study proves the superiority of the mechanical property of a metal matrix composites over AC4CH according to the previous tests and results that were mentioned above. One excellent property of matrix material composites is the infiltrated $TiO_2$ reinforcement. This material is a good substitute for the existing materials that are used in the development of industries today.

  • PDF

A Study on the Acoustic Properties of Porous Material by Using Acoustic Transfer Matrix (전달행렬법에 의한 다공질 흡음재의 음향특성 연구)

  • 박철희;주재만;염창훈
    • Journal of KSNVE
    • /
    • v.6 no.5
    • /
    • pp.635-644
    • /
    • 1996
  • In this paper, Allard's modelling method which employs the method of acoustic transfer matrix(ATM) is applied to yield more precise results in the analysis of porous sound absorbing material. The method of ATM, based on Biot's theory, is known to play an important role in the estimation of the sound absorption when a sound projects onto the material. In the case of a single layered porous sound absorbing material, the surface impedance and the absorption coefficient by using the method of ATM are estimated. With the variation of the material properties, sound absorption characteristics and analyzed. Transmission Loss in a combination of the porous sound absorbing material with a thin plate is predicted.

  • PDF

Effect of Allyl Modified/Silane Modified Multiwalled Carbon Nano Tubes on the Electrical Properties of Unsaturated Polyester Resin Composites

  • Swain, Sarojini;Sharma, Ram Avatar;Patil, Sandip;Bhattacharya, Subhendu;Gadiyaram, Srinivasa Pavan;Chaudhari, Lokesh
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.6
    • /
    • pp.267-272
    • /
    • 2012
  • Considering the properties of the carbon nano tubes (CNT), their inclusion into the polymer matrix vastly increases the properties of the resultant composite. However, this is not the case due to the poor interfacial adhesion of the CNT and the polymer matrix. The present approach focuses on increasing the interaction between the polymer matrix and the CNT through the chemical modification of the CNT resulting in allyl ester functionalized carbon nanotubes (ACNT) and silane functionalized carbon nano tubes (SCNT) which are capable of reacting with the polymer matrix during the curing reaction. The addition of ACNT/SCNT into unsaturated polyester resin (UPR) resulted in the improvement of the electrical properties of resulted nanocomposites in comparison to the CNT. The surface resistivity, volume resistivity, dielectric strength, dry arc resistivity, and the comparative tracking index of the nanocomposites were significantly improved in comparison to CNT. The chemical modification of CNT was confirmed via spectroscopy.

Characteristics of matrix OEL devices that fabricated by side-by-side methode (side by side 방법으로 제작한 matrix 유기 발광 소자의 발광특성)

  • Son, Chul-Ho;Yeo, Cheol-Ho;Shin, Kyung;Lee, Young-Jong;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.366-369
    • /
    • 2001
  • In this study, the matrix Organic Electroluminescence (OEL) device, that was consisted of R,G,B pixels. We fabricated OEL devices by side by side methode and, used organic material Alq3 as green, DCM as red and Butyl PBD as blue ETL. We investigated the characteristic of brightness and current density for matrix OEL device. As the results, each color devices has minimum about $100cd/m^{2}$ brightness and maximum luminescence was $2500cd/m^2$ in green OEL device.

  • PDF

Characteristics of matrix OEL devices that fabricated by side-by-side methode (side by side 방법으로 제작한 matrix 유기 발광 소자의 발광특성)

  • Son, Chul-Ho;Yeo, Cheol-Ho;Shin, Kyung;Lee, Young-Jong;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.366-369
    • /
    • 2001
  • In this study, the matrix Organic Electroluminescence (OEL) device, that was consisted of R,G,B pixels. We fabricated OEL devices by side by side methode and, used organic material Alq3 as green, DCM as red and Butyl PBD as blue ETL. We investigated the characteristic of brightness and current density for matrix OEL device. As the results, each color devices has minimum about 100 cd/㎡ brightness and maximum luminescence was 2500cd/㎡ in green OEL device

  • PDF