• 제목/요약/키워드: Maximum Demand

검색결과 733건 처리시간 0.031초

퍼지로직 알고리즘을 이용한 최대수요전력 제어기의 개발 (DEVELOPMENT OF A MAXIMUM DEMAND CONTROLLER USING FUZZY LOGIC)

  • 한흥석;정기철;성기철;윤상현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.778-780
    • /
    • 1996
  • The predictive maximum demand controllers often bring about large number of control actions during the every integrating period and/or undesirable load-disconnecting operations during the begining stage if the integrating period. To solve these problems, a fuzzy predictive maximum demand control algorithm is proposed, which determines the sensitivity if control action by urgency if the load interrupting action along with the predicted demand reading to the target or the time arriving at the end stage if the integrating period. A prototype controller employing the proposed algorithm also is developed and its performances are tested by PROCOM SYSTEMS Corperation of Korea.

  • PDF

건구온파를 오인한 장기최대전력수요예측에 관한 연구 (Long-Term Maximum Power Demand Forecasting in Consideration of Dry Bulb Temperature)

  • 고희석;정재길
    • 대한전기학회논문지
    • /
    • 제34권10호
    • /
    • pp.389-398
    • /
    • 1985
  • Recently maximum power demand of our country has become to be under the great in fluence of electric cooling and air conditioning demand which are sensitive to weather conditions. This paper presents the technique and algorithm to forecast the long-term maximum power demand considering the characteristics of electric power and weather variable. By introducing a weather load model for forecasting long-term maximum power demand with the recent statistic data of power demand, annual maximum power demand is separated into two parts such as the base load component, affected little by weather, and the weather sensitive load component by means of multi-regression analysis method. And we derive the growth trend regression equations of above two components and their individual coefficients, the maximum power demand of each forecasting year can be forecasted with the sum of above two components. In this case we use the coincident dry bulb temperature as the weather variable at the occurence of one-day maximum power demand. As the growth trend regression equation we choose an exponential trend curve for the base load component, and real quadratic curve for the weather sensitive load component. The validity of the forecasting technique and algorithm proposed in this paper is proved by the case study for the present Korean power system.

  • PDF

마이크로그리드를 기반으로 한 중소 산업용수용가의 최대수요전력 저감방안 (The Maximum Demand Power Reduction of Small Industrial Factory based on Microgrid)

  • 장홍순;김철진;박상원
    • 전기학회논문지P
    • /
    • 제66권1호
    • /
    • pp.7-14
    • /
    • 2017
  • Recently, the power consumption of industrial consumer has increased rapidly, causing problems such as lack of power reserve margin in summer and winter, and therefore there is a growing need for maximum demand power management to consumers. In this paper, we studied small microgrid system consisting of battery ESS and photovoltaic power system, applied to small and medium sized factories to reduce the maximum demand power of daily industrial power load. To verify the validity of the study, we simulated a small microgrid system using Matlab/Simulink software. As a result of applying the simulation to small and medium sized plants that consume a lot of power, it is confirmed that there is a 13% reduction in demand compared to the existing maximum demand power. This result is expected to contribute to the improvement of the power reserve margin.

경기도 소방재난본부에 소속된 두 구급대의 출동수요 분석 (An Analysis of Call Demands of Two Squads In Kyonggi Provincial fire and Disaster Headquarters)

  • 엄태환
    • 한국응급구조학회지
    • /
    • 제6권1호
    • /
    • pp.77-86
    • /
    • 2002
  • The purposes of this research which was conducted by surveying lost/added unit hours reports, unit hour demand analysis worksheets from prehospital care reports of two squads in Kyonggi Provincial Fire and Disaster Headquarters for 20 weeks (January 1, 2002 - May 20, 2002) are to get Unit Hour Utilizations. Call Demands such as Unit Hour Demand, Simple Average Demand, High Average Demand, Peak Average Demand, the High Actual Demand. The conclusions from this analysis were summarized as follows: (1) By revealing Unit Hour Produced 3223.9, Call Volume 964, Unit Hour Utilization 0.299 at the Squad A and Unit Hour Produced 3328.4, Call Volume 901, Unit Hour Utilization 0.271 at the Squad B induced Korean Squads to chance identification, definition, direction of Unit Hour Utilization. (2) By revealing Simple Average Demand 7.4 on Monday Tuesday, High Average Demand 9.6 on Tuesday Friday. Peak Average Demand 11.5 on Tuesday, the High Actual Demand 12 on Tuesday Wednesday at the Squad A and Simple Average Demand 6.8 on Sunday, High Average Demand 10.4 on Monday, Peak Average Demand 11.5 on Monday, the High Actual Demand 13 on Monday at the Squad B enabled Korean Squads to utilize System Status Management. (3) The Maximum Calls per Unit Hour were 115 for 23:00~23:59, the Minimum Calls per Unit Hour were 46 for 05:00~05:49 in two squads. The Maximum Calls per Unit Hour were 7.4 on Tuesday Saturday, the Minimum Calls per Unit Hour were 6.1 on Thursday at the Squad A. The Maximum Calls per Unit Hour were 7.3 on Monday Saturday, the Minimum Calls per Unit Hour were 5.6 on Thursday at the Squad B. (4) Analyzing demand for EMTs in the optimum emergency medical service of Korea, we have been able to utilize this Unit Hour Utilization in company with the established estimation methods such as international comparisons or the number of ambulances for scientific reasonable estimation. (5) These Call Demands which were limited to the demand time in this study will make us expect some following studies including demand time, demand time, demand map for Strategic Deployment.

  • PDF

이앙시기 및 담수심 변화에 따른 논벼 수요량 변화 분석 (Analysis of Variance of Paddy Water Demand Depending on Rice Transplanting Period and Ponding Depth)

  • 조건호;최경숙
    • 한국농공학회논문집
    • /
    • 제63권3호
    • /
    • pp.75-85
    • /
    • 2021
  • This study evaluated variations in the paddy rice water demand based on the continuous changing in rice transplanting period and ponding depth at the four study paddy fields, which represent typical rice producing regions in Korea. Total 7 scenarios on rice transplanting periods were applied while minimum ponding depth of 0 and 20 mm were applied in accordance with maximum ponding depth ranging from 40 mm to 100 mm with 20 mm interval. The weather data from 2013 to 2019 was also considered. The results indicated that the highest rice water demand occurred at high temperature and low rainfall region. Increased rice transplanting periods showed higher rice water demand. The rice water demand for 51 transplanting days closely matched with the actual irrigation water supply. In case of ponding depth, the results showed that the minimum ponding depth had a proportional relationship with rice water demand, while maximum ponding depth showed the contrary results. Minimum ponding depth had a greater impact on rice water demand than the maximum ponding depth. Therefore, these results suggest that increasing the rice transplanting period, which reflects the current practice is desirable for a reliable estimation of rice water demand.

최대전력 분석시뮬레이터 개발 및 조명설비 제어 시뮬레이션 (Maximum Power Analysis Simulator Development & Lighting Installation Control Simulation)

  • 장홍순;한영섭;서상현
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.95-99
    • /
    • 2013
  • The maximum power analysis simulator took advantage of the facilities and power consumption reduction simulator test scenario development and testing of improvement in the scenario. As a maximum demand power controller, Maximum power analysis simulator performs control and disperasion of maximum demand power by calculating base power, load forecast, and present power which are based on signal of watt-hour meter to keep the electricity under the target. In addition, various algorithms to select appropriate control methode on each of the light installations through the peak demand power is configured to management. The simulation shows the success of control power for the specified target controlled by five sequential lighting installations.

전력선 모뎀을 이용한 최대 수요전력 관리 시스템 (Demand Controller Management System using Power Line Modem)

  • 김수곤;임병국;이원선;전희종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1067-1070
    • /
    • 2002
  • The maximum demand power management system(the demand controller) is an equipment for demand management. If the pre-estimated load is over the preset power, the demand controller make warnings and break the load circuit according to predefined priority. Then consumption power is maintained below the maximum demand power level. The DTU receives the control commands from demand controller, and then controls loads. In this paper, the power line cables are used for communication between the demand controller and DTUs and monitoring PC. The experiments show that the proposed system is compatible with the conventional system, and feasible for new or remodeling plant.

  • PDF

OLTC를 활용한 도시철도 최대전력 감축에 관한 연구 (The study on Reduction of Demand Power in Urban Railway using OLTC)

  • 김한수
    • 한국전자통신학회논문지
    • /
    • 제11권10호
    • /
    • pp.963-968
    • /
    • 2016
  • 논문에서는 도시철도의 변전소의 최대수요전력을 줄이기 위한 새로운 방법으로 OLTC(:On Load Tap Changer)를 갖는 변압기의 사용을 제안한다. 국내의 대부분의 도시철도는 전동차에 필요한 전력을 다이오드 방식으로 정류하며 DC 1500[V]로 공급한다. 변전소가 병렬로 연결되어 있기 때문에 수전전압이 상승하면 정류기 전압도 상승하게 되고 변전소의 최대전력도 증가하게 된다. 시뮬레이션 결과를 통해 본 논문에서 제안하는 방법이 최대수요전력의 증가를 상당히 제한할 수 있음을 보인다.

상수사용량(上水使用量)의 확률분포(確率分布) 특성(特性) (Probability Distribution Characteristics of water Supply Demand)

  • 목동우;현인환
    • 상하수도학회지
    • /
    • 제8권2호
    • /
    • pp.35-42
    • /
    • 1994
  • This study is to analyse probability distribution characteristics of water supply demand. Two cities located near Seoul were selected as study areas. In this study, two probalility distribution types were tested using the K-S(Kolmogorov-Smirnov) method. The K-S method was used to prove the goodness of the selected distribution type. And also, the goodness of maximum day demand to average day demand ratio which was obtained by field data was tested. Conclusions are as follows. 1.Bothl normal distribution type and lognormal distribution type are appropriate as the probalility distribution type for the water supply demand. 2. The probability distribution characteristics can be used to test the goodness of the maximum day to average day demand ratio.

  • PDF

국내 전력수급 방안 (Electric Power Supply & Demand measures in korea)

  • 이기선
    • 기술사
    • /
    • 제44권2호
    • /
    • pp.29-33
    • /
    • 2011
  • In recent years, maximum electric power demand has been increasing steadily. But, Electric Power Supply & Demand problem is occurring due to lack of electric power reserve ratio caused by electric power peak. For this reason, I investigated the current status of the Electric Power Supply & Demand and established Electric Power Supply & Demand and established Electric Power Supply & Demand measures. I will expect that this paper will be contributed balanced and stable Electric Power Supply & Demand management.

  • PDF