• Title/Summary/Keyword: Mercury ion-selective electrode

Search Result 6, Processing Time 0.025 seconds

The Potentiometric Performance of Mercury (II) Ion-Selective Electrode Based on Tetracycline Antibiotics

  • Baek, Jong-Gyu;Rhee Paeng, In-Sook
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.1
    • /
    • pp.59-63
    • /
    • 2008
  • Poly (vinylchloride) (PVC) membrane electrodes based on neutral carrier, tetracycline was prepared as an active sensor for Hg(II) ion, and tested in different contents of the potassium tetrakis (4-chlorophenyl) borate (KTpClPB) as lipophilic salt. Bis (2-ethylhexyl) sebacate (DOS), bis(l-butylpentyl) adipate (BBPA), 2-nitrophenyl octyl ether (NPOE) and dibutyl phthalate (DBP) were used as diverse plasticizing solvent mediators. This electrode shows excellent potentiometric response characteristics and display good linearity with log $[Hg^{+2}]$ versus EMF response, over a range of concentrations between $10^{-7}$ and $10^{-3}M$. With 30.8mV/decade Nernstian slope, the detection limit was $6.9{\times}10^{-9}M$ and the response time was less than 20s. The proposed electrode yields very good selectivity for mercury (II) ion over many cations such as alkali, alkaline earth, transition and heavy metal ions. And it shows a very stable potential values in a wide pH range. This reliable electrode prepared was kept at least a month without considerable alteration in their response to Hg (II) ion.

A Highly Selective Mercury(II) Ion-Selective Membrane Sensor (고 선택성 수은(II) 이온 막 센서)

  • Ensafi, Ali A.;Meghdadi, S.;Allafchian, Ali R.
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.4
    • /
    • pp.324-330
    • /
    • 2007
  • A new ion selective PVC membrane electrode is developed as a sensor for mercury(II) ions based on bis(benzoylacetone) propylenediimine (H2(BA)2PD) as an ionophore. The electrode shows good response characteristics and displays, a linear Emf vs. log[Hg2+] response over the concentration range of 1.0×10-6 to 1.0×10-1 M Hg(II) with a Nernstian slope of 29.8±0.75 mV per decade and with a detection limit of 2.2×10-7 M Hg(II) over the pH range of 2.5-11.5. Selectivity concentrations for Hg(II) relative to a number of potential interfering ions were also investigated. The sensor is highly selective for Hg(II) ions over a large number of cations with different charge. The sensor has been found to be chemically inert showing a fast response time of 60 s and was used over a period of 3 months with a good reproducibility (S = 0.27 mV). The electrode was successfully applied to determine mercury(II) in real samples with satisfactory results.

Synthesis of a New Hexadendates Schiff's Base and Its Application in the Fabrication of a Highly Selective Mercury(II) Sensor

  • Ganjali, M.R.;Norouzi, P.;Alizadeh, T.;Salavati-Niasari, M.
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.1
    • /
    • pp.68-72
    • /
    • 2007
  • A new PVC membrane potentiometric sensor that is highly selective to Hg2+ ions was prepared, using bis(2-hydroxybenzophenone) butane-2,3-dihydrazone (HBBD) as an excellent hexadendates neutral carrier. The sensor works satisfactorily in the concentration range of 1.0 × 10-6 to 1.0 × 10-1 mol L-1 (detection limit 4 × 10-7 mol L-1) with a Nernstian slope of 29.7 mV per decade. This electrode showed a fast response time (~8 s) and was used for at least 12 weeks without any divergence. The sensor exhibits good Hg2+ selectivity for a broad range of common alkali, alkaline earth, transition and heavy metal ions (lithium, sodium, potassium, magnesium, calcium, copper, nickel, cobalt, zinc, cadmium, lead and lanthanum). The electrode response is pH independent in the range of 1.5-4.0. Furthermore, the developed sensor was successfully used as an indicator electrode in the potentiometric titration of mercury ions with potassium iodide and the direct determination of mercury in some binary and ternary mixtures.

Hg(II) ion- Selective Electrodes with Neutral Carriers of Macrocycles (거대고리 중성 운반체를 갖는 Hg(II)이온 선택성 전극)

  • 정오진
    • Journal of Environmental Science International
    • /
    • v.5 no.2
    • /
    • pp.211-220
    • /
    • 1996
  • New thin-and diselena-crown ethers containing two suffer and selenium donor atoms have been prepared. And then, mercury ($Hg^{2+}$) ion-selective electrodes with PVC-plasticizer (STPB) based on some macrocycles as neutral carriers were also made. The electrochemical selectivities for various ions, and the effects for macrocycles, matrix of membranes, ratio of plasticizer to macrowcles, concentration and pH of test solution were investigated on the $Hg^{2+}$ ion-selective electrodes. The 1, 10-diselena-18-crown-6-PVC-STPB (sodium tetraphenylborate) exhibited good linear responses of ${28.2}\pm{0.6}$ decade-1 for $Hg^{2+}$ ion in the conientration ranges of $10^{-2}~10^{-6}$ M $Hg^{2+}$ ion. This electrode exhibited comparatively good selectivities for $Hg^{2+}$ ion in comparison with alkali and alkaline earth metal ions, some heavy metal ions and rare earth metal ion in the range of pH 2.5~6.0. In addition, this electrode was applied as a sensor in the titration of $Hg^{2+}$ ion with $1^-$ ion in water.

  • PDF

Determination of Ultra Trace Levels of Copper in Whole Blood by Adsorptive Stripping Voltammetry

  • Attar, Tarik;Harek, Yahia;Larabi, Lahcen
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.5
    • /
    • pp.568-573
    • /
    • 2013
  • A selective and sensitive method for simultaneous determination of copper in blood by adsorptive differential pulse cathodic stripping voltammetry is presented. The procedure involves an adsorptive accumulation of Cu(II)-ETSC (4- ethyl-3-thiosemicarbazide) on a hanging mercury drop electrode, followed by a stripping voltammetry measurement of reduction current of adsorbed complex at about -715 mV. The optimum conditions for the analysis of copper (II) ion are : pH 10.3, concentration of 4-ethyl-3-thiosemicarbazide $3.25{\times}10^{-6}$ M and an accumulation potential of -100 mV. The peak current is proportional to the concentration of copper over the range 0.003-125 ng/mL with a detection limit of 0.001 ng/mL and an accumulation time of 60 s. Moreover, with the use of the proposed method, there is a considerable improvement in the detection limit, the linear dynamic range and the deposition time, compared with the methods of adsorptive stripping voltammetry for the determination of copper. The developed method was validated by analysis of whole blood certified reference materials.

Electrochemical Determinations of Methylanilinium Ion Mixtures by the Stereoselective Complexations of Host-Guest (호스트-게스트의 입체선택적 착물형성에 의한 메틸아닐리늄 이온 혼합물의 전기화학적 분석)

  • Jung, Jong Hwa;Chang, Duk Jin;Lee, Bu-Yong;Seo, Mu Ryong;Kim, Jae Sang;Lee, Shim Sung
    • Analytical Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.239-247
    • /
    • 1992
  • The complexations and selectivities of the 10 species of mono- and dimethylsubstituted anilinium ions with 18-crown-6 in methanol are examined at dropping mercury electrode. The stability constants of these complexes varies drastically due to the steric hindrance by the positions and numbers of methyl groups. And the analyses of the isomeric mixtures of methylanilinium, which are impossible to detect due to the overlapped peaks in normal conditions, were also accomplished by the additions of 18-crown-6 as the supporting complexing agent using the selective complexations by the steric hindrance effects. As results in case of the difference of stability, ${\Delta}log\;K$ were about 0.7~1.3, it was possible to confirm the existence of two species qualitatively. Otherwise when ${\Delta}log\;K$ were large than 1.6, the quantitative determinations of each species could be accomplished sucessfully. From these results it is deduced that the selective recongnition of the positions and numbers of methyl groups as the steric hindrance in anililniums by 18-crown-6 cause the large variation of the magnitudes of negative shift of reduction waves for guest ions in mixtures.

  • PDF