• Title/Summary/Keyword: Meridional shape

Search Result 28, Processing Time 0.03 seconds

Design of Impeller and Diffuser for Mixed Flow Pump with Inverse Design Method (역설계 방법을 적용한 사류펌프의 임펠러 및 디퓨저 설계)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Kim, Jun-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1322-1325
    • /
    • 2009
  • The impeller and vane diffuser for the mixed flow pump(NS550) was designed by using meridional selection program and inverse design method. We decided the meridional shape of the impeller from the meridional design parameter, such as the specific speed and maximum diameter at the impeller exit. The meridional shape of vane diffuser was set from the impeller shape, distribution of cross sectional area and maximum diffuser diameter. The angle of impeller blade and diffuser vane was designed by using inverse design method. The predicted overall performance by using commercial CFD code(ANSYS CFX-11) shown good agreement with design goals.

  • PDF

Ultimate Behavior of Reinforced Concrete Hyperbolic Cooling Tower (R/C 쌍곡 냉각탑의 극한 거동)

  • Min, Chang Shik;Kim, Saeng Bin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.59-70
    • /
    • 1992
  • Inelastic nonlinear behavior of a hyperbolic cooling tower under wind loading is studied using a finite element program developed on a Cray Y-MP. Convergence studies for the elastic and inelastic analyses are performed using three mesh models. It is shown that the mesh convergence plays an important role in accurately predicting the inelastic behavior of a cooling tower. Even though the cooling tower resists the applied forces through membrane stresses, it is found that the bending stresses play an important role in the failure and behavior of the cooling tower. The present analysis gives a shape factor of 1.48, which indicates a significant redistribution of meridional stresses. It is further evidenced by the distribution of meridional reinforcement yielding which reaches up to $30^{\circ}$ from the windward meridian. The present practice of using elastic analysis for calculating the design stresses appears to be at least safe and conservative. A more comprehensive study should lead to conclusions that would allow use of a higher-than-one shape factor, thus requiring less meridional reinforcement than the present design method does.

  • PDF

Design Optimization of a Centrifugal Compressor Impeller Considering the Meridional Plane (자오면 형상을 고려한 원심압축기 임펠러 최적설계)

  • Kim, Jin-Hyuk;Choi, Jae-Ho;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.3
    • /
    • pp.7-12
    • /
    • 2009
  • In this paper, shape optimization based on three-dimensional flow analysis has been performed for impeller design of centrifugal compressor. To evaluate the objective function of an isentropic efficiency, Reynolds-averaged Navier-Stokes equations are solved with SST (Shear Stress Transport) turbulence model. The governing equations are discretized by finite volume approximations. The optimization techniques based on the radial basis neural network method are used for the optimization. Latin hypercube sampling as design of experiments is used to generate thirty design points within design space. Sequential quadratic programming is used to search the optimal point based on the radial basis neural network model. Four geometrical variables concerning impeller shape are selected as design variables. The results show that the isentropic efficiency is enhanced effectively from the shape optimization by the radial basis neural network method.

Three Freshwater Lembadion Ciliates (Peniculida, Lembadionidae) Newly Reported from Korea

  • Kim, Sung Hoon;Yoon, Jae Sool;Yoon, Seong Myeong;Shin, Mann Kyoon
    • Animal Systematics, Evolution and Diversity
    • /
    • v.33 no.4
    • /
    • pp.246-255
    • /
    • 2017
  • Three freshwater ciliates, Lembadion lucens (Maskell, 1887) Kahl, 1931, L. bullinum ($M{\ddot{u}}ller$, 1786) Perty, 1849, and L. magnum (Stokes, 1887) Kahl, 1931, belonging to the genus Lembadion Perty, 1849 are newly reported from Korea with detailed descriptions and illustrations based on live observation and protargol impregnation. Lembadion lucens is characterized by following characteristics: $52-91{\times}33-64{\mu}m$ body size in vivo; ovoid and slightly asymmetric body shape; 27-49 somatic kineties; and 55-80% of whole pellicle covered with meridional lines with rectangular meshes in posterior portion. Lembadion bullinum is distinguishable from its congeners by its body size of $110-130{\times}60-73{\mu}m$ in vivo; ovoid body shape; oral aperture occupying about four-fifths of ventral side; 48-55 somatic ciliary rows; meridional lines with rectangular meshes except anterior portion (about 16% of body) on pellicle. Lembadion magnum is also characterized by its body size of $70-90{\times}37-50{\mu}m$ in vivo; obliquely asymmetric anterior end of body; oral aperture occupying about more than four-fifths of ventral surface, and opened longitudinally entire ventral surface; 45-61 somatic ciliary rows; meridional lines without rectangular meshes on whole pellicle of body. The present study is the first description of the genus Lembadion from Korea.

Design Optimization of Centrifugal Pump Impellers in a Fixed Meridional Geometry using DOE

  • Kim, Sung;Choi, Young-Seok;Lee, Kyoung-Yong;Yoon, Joon-Yong
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.2
    • /
    • pp.172-178
    • /
    • 2009
  • This paper reports on an investigation (using RSM with commercial CFD software) of the performance characteristics of the impeller in a centrifugal pump. Geometric parameters of vane plane development were defined with the meridional shape and frontal view of the impeller. The parameters are focused on the blade-angle distributions through the impeller in a fixed meridional geometry. For screening, a $2^k$ factorial design has been used to identify the important design parameters. The objective functions are defined as the total head rise and the total efficiency at the design flow-rate. From the $2^k$ factorial design results, it is found that the incidence angles and the exit blade angle are the most important parameters influencing the performance of the pump.

Effect of impeller geometrical parameter on the performance of a centrifugal (임펠러 형상변수가 원심펌프 성능에 미치는 영향)

  • Kim, Sung;Choi, Young-Seok;Kim, Joon-Hyung;Yoon, Joon-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1303-1308
    • /
    • 2008
  • This paper presents effects of impeller geometrical parameters on the performance of a centrifugal pump impeller. The effects of meridional parameters and vane plane development parameters on the performance of the impeller were numerically studied using a commercial CFD code and DOE(design of experiments) software. Geometrical parameters in a method of meridional view and vane plane development were selected and defined to generate the 3D impeller shape. The response variables are defined in a total head and efficiency curve with flow rate. The influences of selected design variables on the various objective functions were examined as a result of the calculation using 2k factorial.

  • PDF

Numerical Analysis Techniques and Flow Characteristics of Two-Stage Centrifugal Compressor for R134a Turbo-Chiller (R134a 터보 냉동기용 2단 원심 압축기의 수치해석 기법과 내부유동 특성)

  • Park, Han-Young;Oh, Hyun-Taek;Shin, You-Hwan;Lee, Yoon-Pyo;Kim, Kwang-Ho;Chung, Jin-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.4
    • /
    • pp.29-38
    • /
    • 2007
  • In this study, flow structure in a two-stage centrifugal compressor for a turbo-chiller with the refrigerant, R134a, was numerically investigated at the design point of the compressor using a commercial code. Flow characteristics in the passages of impeller, diffuser and return channel were analyzed in detail including velocity vector, secondary flow, Mach number and pressure contours in blade spanwise and meridional plane for each stage. The estimation on the one-dimensional output from the preliminary design and three-dimensional shape of the impeller blade and the meridional shape of the return channel were performed through the flow analysis, while some numerical schemes and techniques including Multiple Frames of Reference technique, real gas property data and inlet boundary condition changes, which were used in CFD, were compared with their features. The results will be used as reference data for a new design of 3-D impeller shape to improve R134a compressor performance.

Design Optimization of Mixed-flow Pump in a Fixed Meridional Shape

  • Kim, Sung;Choi, Young-Seok;Lee, Kyoung-Yong;Kim, Jun-Ho
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.14-24
    • /
    • 2011
  • In this paper, design optimization for mixed-flow pump impellers and diffusers has been studied using a commercial computational fluid dynamics (CFD) code and DOE (design of experiments). We also discussed how to improve the performance of the mixed-flow pump by designing the impeller and diffuser. Geometric design variables were defined by the vane plane development, which indicates the blade-angle distributions and length of the impeller and diffusers. The vane plane development was controlled using the blade-angle in a fixed meridional shape. First, the design optimization of the defined impeller geometric variables was achieved, and then the flow characteristics were analyzed in the point of incidence angle at the diffuser leading edge for the optimized impeller. Next, design optimizations of the defined diffuser shape variables were performed. The importance of the geometric design variables was analyzed using $2^k$ factorial designs, and the design optimization of the geometric variables was determined using the response surface method (RSM). The objective functions were defined as the total head and the total efficiency at the design flow rate. Based on the comparison of CFD results between the optimized pump and base design models, the reason for the performance improvement was discussed.

A study on forces generated on spherical type LNG tank with central cylindrical part under various static loading

  • Shin, Sang-Hoon;Ko, Dae-Eun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.6
    • /
    • pp.530-536
    • /
    • 2016
  • The number of fabrication shop for spherical type LNG tank is proportional to that of the tank radius to be constructed. Due to limitation of facility investment including building sites, it is practically difficult to fabricate various size tanks with perfectly spherical shape in the yards. The efficient method to be capable of increasing cargo tank volume is to extend vertically the conventional spherical type LNG tank by inserting a cylindrical shell structure. The main purpose of this study is to derive related equations on forces generated on spherical type LNG tank with central cylindrical part under various static loadings in order to establish the simplified analysis method for the initial estimate. In this study, equations on circumferential and meridional force have been derived and verified by relations with the reaction forces per unit length of equator.